Table 5. DSA Preboot messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 7, “Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530,” on page 201 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained service
technician.
v
Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints, tips, and new
device drivers or to submit a request for information.
Message
number
Component
Test
State
Description
Action
202-802-xxx
Memory
Memory Stress
Test
Failed
General error:
memory size is
insufficient to run
the test.
1.
Make sure that all memory is enabled
by checking the Available System
Memory in the Resource Utilization
section of the DSA event log. If
necessary, enable all memory in the
Setup utility (see “Using the Setup
Utility” on page 246).
2.
Make sure that the DSA code is at the
latest level. For the latest level of
DSA code, go to http://
www.lenovo.com/support.
3.
Run the test again.
4.
Run the standard memory test to
validate all memory.
5.
If the failure remains, go to the
Lenovo Web site for more
troubleshooting information at
http://www.lenovo.com/support.
202-901-xxx
Memory
Memory Stress
Test
Failed
Test failure.
1.
Run the standard memory test to
validate all memory.
2.
Make sure that the DSA code is at the
latest level. For the latest level of
DSA code, go to http://
www.lenovo.com/support.
3.
Turn off the system and disconnect it
from power.
4.
Reseat the DIMMs.
5.
Reconnect the system to power and
turn on the system.
6.
Run the test again.
7.
If the failure remains, go to the
Lenovo Web site for more
troubleshooting information at
http://www.lenovo.com/support.
Chapter 4. Diagnostics
95
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...