v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
SeeChapter 7, “Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530,” on page 201 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Sensor CPU
n
OverTemp has
transitioned to critical from a less
severe state.
(
n
= microprocessor number)
Error
A sensor has changed to
Critical state from a less
severe state.
1.
Make sure that the fans are
operating, that there are no
obstructions to the airflow,
that the air baffle is in place
and correctly installed, and
that the server cover is
installed and completely
closed.
2.
Make sure that the heat sink
for microprocessor
n
is
installed correctly.
3.
(Trained service technician
only) Replace microprocessor
n
.
(
n
= microprocessor number)
Sensor CPU
n
OverTemp has
transitioned to non-recoverable
from a less severe state.
(
n
= microprocessor number)
Error
A sensor has changed to
Nonrecoverable state from a
less severe state.
1.
Make sure that the fans are
operating, that there are no
obstructions to the airflow,
that the air baffle is in place
and correctly installed, and
that the server cover is
installed and completely
closed.
2.
Make sure that the heat sink
for microprocessor
n
is
installed correctly.
3.
(Trained service technician
only) Replace microprocessor
n
.
(
n
= microprocessor number)
Sensor CPU
n
OverTemp has
transitioned to critical from a
non-recoverable state.
(
n
= microprocessor number)
Error
A sensor has changed to
Critical state from
Nonrecoverable state.
1.
Make sure that the fans are
operating, that there are no
obstructions to the airflow,
that the air baffle is in place
and correctly installed, and
that the server cover is
installed and completely
closed.
2.
Make sure that the heat sink
for microprocessor
n
is
installed correctly.
3.
(Trained service technician
only) Replace microprocessor
n
.
(
n
= microprocessor number)
32
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Hardware Maintenance Manual
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...