background image

NP301

User Manual

Date: 2011/11/16 Version 3.1.0

Shenzhen 3onedata Technology Co., Ltd
Http://www.3onedata.com.cn

Summary of Contents for NP301

Page 1: ...NP301 User Manual Date 2011 11 16 Version 3 1 0 Shenzhen 3onedata Technology Co Ltd Http www 3onedata com cn ...

Page 2: ...g to their respective manufacturers Agreement As the product version upgrades or other reasons this document is subject to change without notice Unless other agreement this document only as a guide to use all statement information and suggestion in this document without warranty of any kind either expressed or implied Revision History Version No Date Reason V1 0 0 2011 07 Creating Documents V3 1 0...

Page 3: ... HARDWARE DESCRIPTION 2 2 1 PANEL DESCRIPTION 2 2 2 INTERFACE DESCRIPTION 3 2 3 POWER SUPPLY DESCRIPTION 4 2 4 LED INDICATOR 4 CHAPTER 3 APPEARANCE DIMENSION 5 CHAPTER 4 PERFORMACE AND PARAMETER 6 CHAPTER 5 WEB MANAGEMENT FUNCTION 7 5 1 NETWORK SETTINGS 7 5 3 LOG IN WEB INTERFACE 8 5 4 MODE SETTINGS 12 5 5 SYSTEM TOOLS 19 ...

Page 4: ...nfigurations can be done by network and serial port supporting communication across gateway and router In addition it allows users to configurate flexibly IP address Server or Client mode size of packet etc NP301 serial device sever is designed with EMC protection and power supply have overcurrent and overvoltage protection These make it woking stably in hazardous environment Easy wall and DIN Rai...

Page 5: ...Shenzhen 3onedata Technology Co Ltd 2 Chapter 2 Hardware description 2 1 Panel description Front panel Top panel Underside panel ...

Page 6: ... It connects the PC Server Converter and HUB by straight though cable wiring Pin 1 2 3 6 Corresponding connection in MDI 1 3 2 6 3 1 6 2 are used as cross wiring in the MDI X port of Converter and HUB 10Base T is used in MDI MDI X the definition of Pin in the table as below pin MDI signal MDI X signal 1 TX RX 2 TX RX 3 RX TX 6 RX TX 4 5 7 8 Note TX transmit data RX receive data not use 2 2 2 RS 23...

Page 7: ...TS CTS NC 2 3 Power supply description 9 48VDC wide voltage power input the consumption is about 1 4W 2 4 LED Indicator NP301 has 3 LED Indicator include Power Link ACT Rx Tx the meaning is as follows Power input steadily Power LED bright all along Network connect naturally Link ACT LED bright all along Serial interface has data receive Rx Tx LED blinking ...

Page 8: ...Shenzhen 3onedata Technology Co Ltd 5 Chapter 3 Appearance dimension Unit mm ...

Page 9: ...n Odd Space Mark Data bit 5bit 6bit 7bit 8bit Baud rate 300bps 115200bps Flow control RTS CTS or XON XOFF Direction control RS485 side adopt ADDC technology auto text and control data transfer direction Loading RS 485 422 side support 32 nodes customize 128 nodes loopback Transmission RS 485 422 side 1200M RS 232 port 15M Interface protection 1500W surge protection 15KV static protection Interface...

Page 10: ...owser The IP address of the NP301 and PC must be in the same Local Area network You can modify PC s or NP301 s IP address to make sure that they are in the same Local Area Network Operating process can follow method 1 or method 2 as below Method 1 Modify PC s IP address Click Start Control panel network connections Local area Connection Properties Internet protocl TCP IP Setting PC s IP address 19...

Page 11: ...tting Setting working mode Local port destination address destination port connection mode connection alive etc option sessions AT command settings Enter into AT mode 3 mode I O Port Triggering user can not configure in hardware type CtrlBreak Triggering character string Triggering System tools Resume factory Resume the device into the status when leaved factory Configuration files Download or upl...

Page 12: ...e as figure 5 3 Web setting interface divide as 1 Title area 2 Menu bar 3 Setting area Click menu of the mean bar can enter into relevant interface setting area display the status of the NP301 and can configuration Figure 5 3 If user name or password input incorrectly 3 times continuously you must access afresh ...

Page 13: ...s IP address IP address is a 32 bits length address provided the device that connect to the Internet IP address has 2 filed net id and host id IP address can set in static IP or DHCP Subnet Mask Mask is an IP address corresponding 32 bit number it has 1 and 0 Mask can divide IP address into 2 parts subnet addresses and host computer addresses 1 bit in IP address and mask correspond subnet address ...

Page 14: ...CP automatically obtain IP address please ensure DHCP Server is already in the network and can obtain IP address successfully After automatically obtain IP address it is need to use software VSP manager software to search the device and obtain the IP address of the device ...

Page 15: ...he corresponding drop down menu Serial settings Web interface as figure 5 5 When NP301 communicate with serial interface device NP301 s setting is as follows Figure 5 5 Some items related with serial settings Serial Mode Baud Rate Parity Data Bits Stop bits Max Data Packets Lenth and Character Delay CtrlBreak Default Output Time The meaning of these configuration options are explained below Serial...

Page 16: ...ional Function decription Sessions 1 4 Working mode TCP Client TCP Server UDP TCP Auto Local Area ports 1 65535 Destination address Destination ports 1 65535 Connection mode Immediately Data trigger Keep alive 1 65535 s Sessions Each serial port of serial device servers can support 1 4 sessions It means serial port of serial device server send the received data to Ethernet through socket More than...

Page 17: ...matic if there do not have data transfer NP301 connection will cut off If set 0 means do not care how much time vacancy NP301 do not cut off voluntary The range is 1 65535s Default is 300s The figure below is the configuration interface of TCP Client Mode Session 1 is setting to local address available for router 192 168 2 168 the Destination Port connected to serial port is host computer 192 168 ...

Page 18: ...k mode NP301 is server and also client the relavant setting is Local port Destination address and Destination port It can support point to point and multicast UDP setting method is the same as TCP 4 TCP Auto In this Mode serial device server can act as server or client Before setting this Mode please ensure related parameters are correct when you turn on the server mode client mode is automaticall...

Page 19: ... through I O port trigger CtrlBreak trigger Open Virtual Serial Port click Ctrl PauseBreak then open Web page of NP301 click Operation Settings AT Command Settings to enter into AT Commande Mode page It is enabled by the second way As Figure 5 9 Character strings trigger Hex By setting Character in Character Strings Trigger Hex Serial Settings The way is to send predefined characters to serial por...

Page 20: ...e chosen serial port is consistent with the port connected with the configuration cable Click OK As figure 5 11 Figure 5 11 Set serial port parameters As shown in Figure 5 12 set the Bits per second in the Properties of serial port is 115200bit s Data bits is 8 parity is None Stop Bits is 1 Flow Control is None Click OK button to enter to Hyper Terminal Window ...

Page 21: ... As figure 5 13 click again Ctrl Break at the same time click Enter until blinking cursor appears on the screen In this time you can input AT configuration order through Hyper Terminal Specific command format and configuration reference 5 5 Figure 5 13 ...

Page 22: ...factory default settings download configuration files upload configuration files system upagrde system restart as figure 5 14 Figure 5 14 1 Restore factory default settings Click System tools Click File management Choice Restore default value Click Start b Alarm Restore factory default file 192 168 1 254 will cover your configuration please confirm Yes or No It will open a new interface input 192 ...

Page 23: ...ct the upgrade files Click Browse Choice the upload files Click Start Upgrade Notice Forbid power supply cut off in upgradeing then start to upgrade After updating it will open a new interface System status 5 System restart Click Restart after 20 second click menu bar and back to the WEB login interface please save the configuration before restart otherwise configuration information will be lost U...

Page 24: ...tion method 1 Through User name admin Password admin Enter into WEB interface Click Show all in the function menu choice user nam and password enter into login settings interface 2 Input new user name and password and retype password in the login settings Figure 5 15 3 Input finished click Submit Password modified successful it will go to the information page automatic ...

Reviews: