manualshive.com logo in svg
background image

 

 

 

Intel

®

 Server Board SCB2 

Product Guide 

 

A Guide for Technically Qualified Assemblers of Intel

®

 Identified 

Subassemblies/Products 

 

Order Number:  A55880-003 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание SCB2 - Server Board Motherboard

Страница 1: ...Intel Server Board SCB2 Product Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies Products Order Number A55880 003 ...

Страница 2: ...rpose merchantability or infringement of any patent copyright or other intellectual property right Intel products are not designed intended or authorized for use in any medical life saving or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur Intel may make changes to specifications a...

Страница 3: ... Locks 17 2 Installation Procedures Install the I O Shield 21 Rearrange the Standoffs 22 Server Board Bumpers 23 Install the Server Board 24 Installing Processors 25 Install the Processor Terminator 28 Memory 29 Connect Cables 30 3 Upgrading Tools and Supplies Needed 31 Cautions 31 Memory 32 Processors 33 Adding or Replacing a Processor 34 Removing a Processor 37 Installing and Removing a Terminat...

Страница 4: ...ild Utility 56 Running the Promise FastBuild Utility 56 Direct Platform Control DPC Console 56 DPC Console Modes of Operation 57 Running the DPC Console 57 Using the System Setup Utility 57 What You Need to Do 58 Running the SSU 58 Customizing the SSU 59 Launching a Task 60 MultiBoot Options Add in 60 Password Add in 60 SEL Manager Add in 62 FRU Manager Add in 63 SDR Manager Add in 64 System Updat...

Страница 5: ...tivity Light Does Not Light 88 CD ROM Drive Activity Light Does Not Light 88 Cannot Connect to a Server 88 Problems with Network 89 Problems with Application Software 90 Bootable CD ROM Is Not Detected 90 6 Technical Reference Server Board Jumpers 91 Diagnostic LEDs 92 7 Regulatory and Integration Information Product Regulatory Compliance 97 Product Safety Compliance 97 Product EMC Compliance 97 P...

Страница 6: ...t the Processor and Lower the Locking Bar 34 19 Installing the Heat Sink 35 20 Attach the Heat Sink 36 21 Connect the Heat Sink Fan 36 22 Installing a Terminator 38 23 Replacing the Back up Battery 40 24 System Setup Utility Main Window 59 25 Platform Event Manager Main Window 66 26 Platform Event Paging Dialog 67 27 BMC LAN Configuration Dialog 68 28 Platform Event Action Dialogs 71 29 Emergency ...

Страница 7: ... SDRAM DIMMs 133 MHz ECC registered PC 133 compliant 72 bit 168 pin gold contact 3 3V A 1U chassis requires low profile LP 1 2 inch DIMMs Up to 6 GB of memory in a 2U chassis Graphics Integrated onboard ATI RAGE XL PCI 64 bit SVGA controller Video Memory 8 MB SDRAM of video memory PCI bus Two PCI riser slots capable of supporting either of the following configurations 1U configuration one full len...

Страница 8: ...MHz 64 bit PCI riser slot low profile L USB 3 4 header M Sys fan 3 connector N CPU 2 fan connector O Secondary processor socket P Primary processor socket Q Sys fan 2 connector R CPU 1 fan connector S Sys fan 1 connector T Aux fan connector U Floppy drive connector V Fan module connector W Main power connector X Auxiliary signal connector Y Floppy FP IDE connector Z Alternate front panel connector...

Страница 9: ...r B Video connector C SCSI connector SCSI server board only D NIC 2 RJ 45 connector E Green Status LED F Yellow Status LED G NIC 1 RJ 45 connector H Green Status LED I Yellow Status LED J PS 2 keyboard mouse connector K RJ 45 serial port L USB 2 connector Figure 2 Back Panel Connectors ...

Страница 10: ...4MB x 2 and as much as 6 GB The controller automatically detects sizes and initializes the memory array depending on the type size and speed of the installed DIMMs and reports memory size and allocation to the server via configuration registers NOTE Use DIMMs that have been tested for compatibility with the server board Contact your sales representative or dealer for a current list of approved mem...

Страница 11: ...erally are terminated through a jumper or resistor pack on the device itself ATA 100 Controller The ATA version of the server board provides an embedded dual channel ATA 100 bus through the use of the Promise Technology PDC20267 ATA 100 controller The controller contains two independent ATA 100 channels that share a single 32 bit 33 MHz PCI bus master interface as a multifunction device The contro...

Страница 12: ...e 82550 PM controller supports the following features 32 bit PCI CardBus master interface Integrated IEEE 802 3 10Base T and 100Base TX compatible PHY IEEE 820 3u auto negotiation support Chained memory structure similar to the 82559 82558 82557 and 82596 Full duplex support at both 10 Mbps and 100 Mbps operation Low power 3 3 V device IP checksum off loading On the SCB2 NIC 1 can be used as both ...

Страница 13: ... Adapter Fault Tolerance Adapter Fault Tolerance AFT is a simple effective and fail safe approach to increase the reliability of server connections AFT gives you the ability to set up link recovery to the server adapter in case of a cable port or network interface card failure By assigning two server adapters as a team AFT enables you to maintain uninterrupted network performance AFT is implemente...

Страница 14: ...er and balances network traffic across the adapters as needed Adapter teams configured for FEC also provide the benefits of AFT To use FEC you must have 2 4 or 8 server adapters installed in your server and linked to the same FEC enabled Cisco switch Keyboard and Mouse The keyboard mouse controller is PS 2 compatible If specified through the System Setup Utility SSU the server may be locked automa...

Страница 15: ...For serial concentrators that require a DSR signal the J6A2 jumper block must be configured as follows The DSR jumper in position 1 and 2 and the DCD jumper in position 1 and 2 Pin 1 on the jumper is denoted by an arrow directly next to the jumper block See Figure 4 Figure 4 J6A2 Jumper Block for DSR Signal For those server applications that require a DB9 type of serial connector an 8 pin RJ45 to ...

Страница 16: ...face ACPI as defined by the ACPI 1 0 and PC97 specifications An ACPI aware operating system can put the system into a state where the hard drives spin down the system fans stop and all processing is halted However the power supply will still be on and the processors will still be dissipating some power so the power supply fans will still run The SCB2 supports sleep states s0 s1 s4 and s5 s0 Normal...

Страница 17: ...le a supervisor password Set and enable a user password Set secure mode to prevent keyboard or mouse input and to prevent use of the front panel reset and power switches Activate a hot key combination to enter secure mode quickly Disable writing to the diskette drive when secure mode is set Disable access to the boot sector of the operating system hard disk drive Using Passwords You can set either...

Страница 18: ...o enable or set the features listed here you must run the SSU and go to the Security Subsystem Group menu The table also refers to other SSU menus and to the Setup utility Table 4 Software Security Features Feature Description Secure mode How to enter secure mode Setting and enabling passwords automatically places the system in secure mode If you set a hot key combination through Setup you can sec...

Страница 19: ...RL D in the Change Password menu of the Supervisor Password Option menu found in the Security Subsystem Group To clear the password if you cannot access Setup change the Clear Password jumper see Chapter 5 Control access to the system other than SSU set user password To control access to using the system set a user password and enable it through Setup To disable a password change it to a blank ent...

Страница 20: ...20 Intel Server Board SCB2 Product Guide ...

Страница 21: ...ening in the back of a chassis The shield has cutouts that match the I O ports 1 Install the shield from inside the chassis Orient the shield so that the cutouts align with the corresponding I O connectors on the server board Make sure the metal fingers are on the inside of the chassis 2 Position one edge A so that the dotted groove is outside the chassis wall and the lip of the shield rests on th...

Страница 22: ...standoffs placed as shown you must rearrange them so they match the holes in the server board Failure to properly rearrange the metal standoffs may cause the server board to malfunction and may permanently damage it Your chassis may be different from the illustration OM11716B Figure 6 Rearrange the Standoffs ...

Страница 23: ...ot already support the board at the locations shown in the illustration The rubber bumpers you provide and install must be the same height as the existing board mount standoffs to properly support your new board Failure to install bumpers or installing bumpers that are too tall or too short may damage your board DO NOT INSTALL server board bumpers in the Intel SR1200 and SR2200 server chassis OM12...

Страница 24: ...s You may need to move cables out of the way to properly install your server board 1 While placing the board on the chassis standoffs carefully position the board I O connectors into the rear chassis I O openings 2 Adjust board position to align mounting holes with standoffs 3 Using the screws that came with your chassis mount the board to the chassis OM11716A Figure 8 Installing the Server Board ...

Страница 25: ...utions at the beginning of this document 2 Raise the locking bar on the socket OM11711 Figure 9 Raising the Locking Bar 3 Aligning the pins of the processor with the socket insert the processor into the socket 4 Lower the locking bar completely OM11712 Figure 10 Installing Processors ...

Страница 26: ...cessor 6 Position the heat sink slot 2 above the socket processor slot 3 7 Aligning the raised metal surfaces place the heat sink on top of the processor 8 Install the heat sink clip with pin 1 inserted into slot 2 OM11708A C A B 2 3 1 Figure 11 Installing the Heat Sink A Heat sink retention clip B Heat sink C Socket and processor ...

Страница 27: ... with the SCB2 server board it will come with a fan for the processor heat sink This fan cannot be used in a 1U server chassis If you are integrating a 2U chassis proceed to the next step 10 Following the instructions provided with the processor install the fan on the processor heat sink 11 Connect the fan to A if it is on the primary processor or to B if it is on the secondary processor OM12163 B...

Страница 28: ...he secondary processor socket A If you are installing two processors skip this section 1 Raise the locking bar B on the socket 2 Aligning the two corner marks on the terminator with the handle side of the socket C insert the terminator into the socket 3 Lower the locking bar completely D OM11710 A B D C Figure 14 Installing the Processor Terminator ...

Страница 29: ...s low profile LP 1 2 inch DIMMs DIMMs must be installed in pairs and in the following order 1a and 1b 2a and 2b 3a and 3b Installed DIMMs must be the same speed and must all be registered For a list of supported memory call your service representative or visit the Intel Support website http support intel com support motherboards server OM11715 3A 1B 2B 3B 1A 2A Figure 15 Installing Memory ...

Страница 30: ...primary secondary connectors ATA server board only C SSI front panel connector see the server board diagram label for pin out D Front panel connector For use in a non Intel chassis only E IDE connector For use in a non Intel chassis only F Main power connector G Fan module connector 7 pin H Fan connectors system and processor I USB header J Floppy connector For use in a non Intel chassis only K CO...

Страница 31: ...sent on power telephone and communication cables Turn off the server and disconnect the power cord telecommunications systems networks and modems attached to the server before opening it Otherwise personal injury or equipment damage can result Electrostatic discharge ESD ESD protection ESD can damage disk drives boards and other parts We recommend that you perform all procedures in this chapter on...

Страница 32: ...rolled by that jumper Take care to grip with but not squeeze the pliers or other tool you use to remove a jumper or you may bend or break the stake pins on the board Memory The server board supports from 128 MB up to 6 GB of registered memory in six DIMM slots NOTE Only PC133 compliant SDRAM is supported by the server board A 1U chassis requires low profile LP 1 2 inch 30 mm tall DIMMs DIMMs must ...

Страница 33: ...er can handle a newer faster processor thermal and power considerations For exact information about processor interchangeability contact your customer service representative or visit the Intel Customer Support website http support intel com support motherboards server scb2 ESD and handling processors Reduce the risk of electrostatic discharge ESD damage to the processor by doing the following 1 To...

Страница 34: ...first processor within one stepping same voltage same speed see the Intel Customer Support website for specifics 1 Observe the safety and ESD precautions given at the beginning of this chapter 2 Remove the chassis cover see your system or chassis documentation for instructions 3 Raise the locking bar on the socket 4 Aligning the pins of the processor with the socket insert the processor into the s...

Страница 35: ...lot 2 above the socket processor slot 3 8 Aligning the raised metal surfaces place the heat sink on top of the processor 9 Install the heat sink clip with pin 1 inserted into slot 2 OM11708A C A B 2 3 1 A Heat sink retention clip B Heat sink C Socket and processor Figure 19 Installing the Heat Sink CAUTION Use care when closing the locking lever do it slowly ...

Страница 36: ...oard it will come with a fan for the processor heat sink This fan cannot be used in a 1U server chassis If you are integrating a 2U chassis proceed to the next step 11 Following the instructions provided with the processor install the fan on the processor heat sink 12 Connect the fan to A if it is on the primary processor or to B if it is on the secondary processor OM12163 B A CPU 1 Fan CPU 2 Fan ...

Страница 37: ...ink fan is present unplug it from the server board and remove it from the heat sink 3 Disengage the retention clip from the processor socket by slowly opening the locking lever until it is vertical 4 Remove the processor from the socket 5 If you removed the processor from the secondary socket and are not replacing it you must install a terminator in its place ...

Страница 38: ...s chapter and the additional cautions given here 2 Raise the locking bar on the socket 3 To install a terminator align the two corner marks on the terminator with the handle side of the socket C and then insert the terminator into the socket 4 To remove a terminator pull it out of the socket and then replace the it with another terminator or install a processor 5 Lower the locking bar B completely...

Страница 39: ...teries according to manufacturer s instructions ADVARSEL Lithiumbatteri Eksplosionsfare ved fejlagtig håndtering Udskiftning må kun ske med batteri af samme fabrikat og type Levér det brugte batteri tilbage til leverandøren ADVARSEL Lithiumbatteri Eksplosjonsfare Ved utskifting benyttes kun batteri som anbefalt av apparatfabrikanten Brukt batteri returneres apparatleverandøren VARNING Explosionsfa...

Страница 40: ... battery the battery pops up 5 Remove the battery from its socket 6 Dispose of the battery according to local ordinance 7 Remove the new lithium battery from its package 8 Being careful to observe the correct polarity lay the battery in the socket 9 Push the battery down the metal retainer locks the battery in the socket 10 Close the chassis 11 Run Setup to restore the configuration settings to th...

Страница 41: ...k space NOTE It is highly recommended that you install the service partition before installing an operating system For more information see the Service Partition section in the Installation Guide for the Intel Server Control This document is included on the Resource CD ROM shipped with your SCB2 server board Configuration Utilities System Software Update Sequence When you update the system softwar...

Страница 42: ...diskettes You can create the diskettes from the CD The CSSU is run from the service partition via the DPC console It provides the same functionality as the SSU but from a remote console Information entered via the SSU CSSU overrides information entered via BIOS Setup 57 FRU SDR Load Utility Use to update the Field Replacement Unit FRU and Sensor Data Record SDR flash components NOTE You must run t...

Страница 43: ...device with an operating system loaded the boot process continues and the system beeps once The following message is displayed Operating System not found 5 At this time pressing any key causes the system to attempt a reboot The system searches all removable devices in the order defined by the boot priority Using BIOS Setup This section describes the BIOS Setup options Use BIOS Setup to change the ...

Страница 44: ...drive and you cannot use BIOS Setup to correct the problem you might need to clear CMOS memory To clear CMOS either of two methods can be used 1 Press the reset button and hold it down for four seconds or more and then while holding the reset button down press the power button Release both buttons at the same time 2 Move the Clear CMOS jumper found on the configuration jumper block on the baseboar...

Страница 45: ... Disk A Not Installed 1 44 1 25 MB 1 2 MB 3 2 88 MB 3 Selects the diskette type Hard Disk Pre delay Disabled Enabled Causes the BIOS to insert a delay before attempting to detect IDE drives in the system Primary IDE Master Press Enter Enters submenu Primary IDE Slave Press Enter Enters submenu Processor Settings Press Enter Enters submenu Language English US French Spanish German Italian Selects w...

Страница 46: ...ppear if processor 1 is absent or disabled Processor 2 CPU ID N A Reports Stepping for Processor 2 Processor 2 L2 Cache Size N A Reports L2 Cache Size for Processor 2 This feature does not appear if processor 2 is absent or disabled Advanced Menu Feature Choices Description PCI Configuration Press Enter Enters submenu Peripheral Configuration Press Enter Enters Submenu Memory Configuration Press E...

Страница 47: ...Slot 1C ROM Enabled Disabled Used to enable or disable an option ROM that may be present on a PCI add in card installed in the slot In a 2U chassis options for additional PCI slots PCI bus C will be displayed USB Function Submenu Feature Choices Description USB Function Enabled Disabled Enables the embedded USB controller Onboard NIC1 and 2 Submenu Feature Choices Description Onboard NIC Enabled D...

Страница 48: ... 2 Diskette Controller Enabled Disabled Used to enable or disable the onboard floppy disk controller Legacy USB Support Disabled Keyboard Only Auto Keyboard Mouse Enables support for legacy USB Front Panel USB Disabled Enabled Used to enable the USB ports accessed through the internal USB header found on the baseboard Memory Configuration Submenu Feature Choices Description Extended Memory Test 1 ...

Страница 49: ...bled by setting it to a null string or by clearing password jumper on server board Set User Password Press Enter When the Enter key is pressed a password prompt appears Press ESC key to abort Once set this can be disabled by setting it to a null string or by clearing password jumper on server board User Access Level Limited No Access View Only Full Sets the User access level for various BIOS setup...

Страница 50: ... PERR Disabled Enabled If enabled PCI bus parity error PERR routes to NMI Assert NMI on SERR Disabled Enabled If enabled PCI bus system error SERR routes to NMI FRB 2 Policy Disable BSP Do not Disable BSP Retry 3 Times Controls the policy of the FRB 2 timeout This option determines when the Boot Strap Processor BSP should be disabled if an FRB 2 error occurs BMC IRQ Disabled IRQ 5 IRQ 11 Sets the ...

Страница 51: ...A and B in the Peripheral Configuration Setup menu Baud Rate 9600 19 2k 38 4k 115 2k Console Redirection when enabled uses the baud rate specified When the Direct Platform Control DPC shares the COM port as console redirection set the baud rate to 19 2k to match DPC baud rate unless the autobaud feature is used Flow Control No flow control CTS RTS XON XOFF CTS RTS CD None disallows flow control CT...

Страница 52: ... CD ROM Drive Attempts to boot from an ATAPI CD ROM drive 4 th Boot Device Intel Boot Agent version 4 Attempts to boot from a network when a network device controlled by a PXE compliant ROM is present in the system Hard Disk Submenu For options on this menu use the up or down arrow keys to select a device Press the or keys to move the device higher or lower in the boot priority list Option Descrip...

Страница 53: ...p data Load Custom Defaults Loads custom defaults saved from previous Custom Save Save Custom Defaults Saves new BIOS settings and stores them as custom default values Discard Changes Discards any changes made to BIOS settings and restores previous settings Temporarily Changing the Boot Device Priority During POST you can change the boot device priority for the current boot process The changes are...

Страница 54: ...des an onboard SCSISelect configuration utility that allows you to configure view the settings of the host adapter and devices in the server The system finds the Adaptec AIC 7899 SCSI host adapter and displays the message Adaptec AIC 7899 SCSI BIOS V x xxx where x xxx is the version number of the SCSISelect utility Pressing Ctrl A at this time allows you to configure the Adaptec AIC 7899 SCSI host...

Страница 55: ...ays Menu for each SCSI Channel Host Adapter Option Comment AIC 7899 at Bus Device Channel 01 06 A or 01 06 B Configure View Host Adapter Settings Press Enter to view the Configuration Menu SCSI Disk Utilities Press Enter to view the SCSI Disk Utilities Menu This menu allows you to format hard disks and or verify disk media When you are finished press Esc and make your selection from the following ...

Страница 56: ...odem or LAN with a capability to run DOS based programs DPC console runs on a client workstation It communicates with a server by Accessing the server management capabilities of the on board NIC A Windows 2000 compatible modem An RS 232 connection to the server COM2 port DPC Console is independent of the server operating system Even when the server is off you can use DPC Console to verify the stat...

Страница 57: ...For DPC to function the server must NOT be in graphics mode If the DPC console fails to connect in EMP within 10 seconds and the server can operate in Re direct mode a prompt is displayed with the option to switch to Re direct mode Service Partition mode Entered when the server reboots from the service partition and the DPC Console has successfully connected to the server through a modem This mode...

Страница 58: ...SSU from non writable media you cannot save user preference settings such as screen colors The SSU supports the ROM DOS V6 22 operating system It may run on other ROM DOS compatible operating systems but they are not supported The SSU will not operate from a DOS box running under an operating system such as Windows Starting the SSU SSU consists of a collection of task oriented modules plugged into...

Страница 59: ...s button lets you change the default colors associated with different items on the screen with predefined color combinations The color changes are instantaneous Mode this button lets you set the desired expertise level novice intermediate expert The expertise level determines which tasks are visible in the Available Tasks section and what actions each task performs For a new mode setting to take e...

Страница 60: ... to display the main window for the selected task OR Highlight the task name and click on OK OR Use the tab and arrow keys to highlight the desired button and press the spacebar or Enter MultiBoot Options Add in The Multiboot Add in MBA provides an interface for selecting Initial Program Load IPL devices Using the MBA the user can identify all IPL devices in the system and prioritize their boot or...

Страница 61: ...r Password button allows the user to set or change the user password used by both the SSU and the system BIOS All changes to the user password take place immediately To Change or Clear the User Password 1 Click on the User password button 2 Enter the old password in the first field 3 Enter the new password in the second field or leave blank to clear 4 Confirm the password by entering it again in t...

Страница 62: ...ntries from a previously stored file Save the system event log entries to a file Clear the system event log entries from the non volatile storage area The SEL Manager has the following menus File The File menu has the following options Open View data from a previously saved SEL file Save As Save the currently loaded SEL data to a file Exit Quits the SEL Viewer SEL The SEL menu has the following op...

Страница 63: ...w data from a previously saved FRU file Save Saves the currently loaded FRU data to a file Save As Saves the currently loaded FRU data to a file Exit Quits the FRU Viewer View The View menu has the following options FRU Info Displays information about the FRU These fields are display only All FRU Areas Displays the current FRU data from the BMC By Device Type Brings up a popup menu that allows you...

Страница 64: ... the SDR These fields are display only Reload Allows the user to re load the SDR data from the server Help The Help menu has the following option Help Topics Displays the SDR Manager version information System Update Add In Clicking on the System Update Add in task allows you to update nonvolatile storage on the server The add in allows you to do the following operations Determine the current revi...

Страница 65: ...owing sources CMOS ESCD PCI records in non volatile storage Non volatile emergency management port EMP platform event paging PEP and Platform event filtering PEF settings Buttons Save To File Displays a file dialog so you can choose a filename and location The CSR then tries to save any non volatile configuration information it can to that file Data is saved from all sources There is no way to cho...

Страница 66: ...included on the main window supports an accelerator key An underlined letter in the text listing the option in VGA mode indicates accelerator keys In text mode accelerator key letters appear highlighted rather than underlined Figure 25 Platform Event Manager Main Window Buttons Configure PEP Opens a new dialog that allows you to configure the Platform Event Paging features Configure LAN Opens a ne...

Страница 67: ...lowing options Enable PEP Allows you to enable or disable the PEP feature entirely A check will appear next to the menu item when PEP is enabled Send Alert Allows you to immediately send a test page with the configuration currently shown on the screen Configure Event Actions Launches the Platform Event Paging Actions Dialog see Figure 28 on page 71 to allow you to configure event actions Help Topi...

Страница 68: ...g is truncated The screen will show the string that was saved after a save operation is done Buttons Save Allows you to save the configuration immediately Close Allows you to close the Platform Event Paging dialog without saving changes If changes have been made you will be prompted to save changes before closing Help Displays help information BMC LAN Configuration Dialog This dialog allows you to...

Страница 69: ...o allow you to configure event actions Help Topics Menu The Help Topics menu has the following options Help Topics Displays help information Enable LAN Alerts Checkbox Enables or disables BMC LAN Alerting Enter New Password Allows you to enter a LAN password The valid range of characters includes ASCII values 32 126 The password must be from 1 16 characters long Verify New Password Enter the same ...

Страница 70: ...The Gateway IP Address will only be saved when DHCP is disabled The IP is entered as a dotted IP e g 192 168 0 2 Subnet Mask Enter the logical or Internet address of the host s subnet The server uses this to decide if the alert destination is in the local subnet or in another subnet relative to the server The Subnet Mask will only be saved when DHCP is disabled The IP is entered as a dotted IP e g...

Страница 71: ...te actions This global flag is in the PEP or BLA dialogs as Enable PEP or Enable BLA checkboxes Figure 28 Platform Event Action Dialogs File Menu The File menu has the following options Save Allows you to save the configuration immediately Close Allows you to close the Platform Event Action dialog without saving changes If you have made changes you will be prompted to save changes before closing H...

Страница 72: ...e prompted to save changes before closing Help Displays help information Emergency Management Port Dialog This dialog allows you to configure the Emergency Management Port features See Figure 29 Figure 29 Emergency Management Port Dialog File The File menu has the following options Save Allows you to save the configuration immediately Close Allows you to close the Emergency Management Port dialog ...

Страница 73: ... string that has been saved is the one that will be shown in the edit box Modem Init String The Modem Init String string is transmitted every time the EMP initializes The length of the paging string is determined at run time from firmware You will be notified if the string is truncated The string that has been saved is the one that will be shown in the edit box System Phone Number Enter the system...

Страница 74: ...the COM2 serial connector Using Platform Event Paging 1 From the SSU main window launch the Platform Event Manager Add in PEM For more information see page 66 2 In the PEM dialog box click the Configure PEP button 3 In the PEP dialog box check the Enable PEP to box 4 Enter your page string in the Paging String field This consists of the following The attention command for your modem generally ATDT...

Страница 75: ...22 NOTE It is recommended that the target system be booted with the Resource CD that accompanied the product However the process for making the diskettes is the same for all the compatible versions of DOS ROM DOS Ver 6 22 is included on the Resource CD 1 Insert and boot to the Resource CD 2 Exit from the menu to a DOS prompt 3 Insert a diskette into the floppy drive 4 At the DOS prompt for an unfo...

Страница 76: ...I Agree to accept the terms and conditions or select Cancel to cancel the installation During the extraction process you will be prompted to insert each of the three labeled diskettes Follow the prompts until the process is completed When completed you will have three diskettes that can be used to update the BIOS the BMC firmware and the FRU SDR records Updating NOTE Do not turn off the system dur...

Страница 77: ...IOS Creating the BIOS Upgrade Diskette The BIOS upgrade file is a compressed self extracting archive that contains the files you need to upgrade the BIOS 1 Copy the BIOS upgrade file to a temporary directory on the hard disk 2 From the C prompt change to the temporary directory 3 To extract the file type the name of the BIOS upgrade file for example 10006BI1 EXE 4 Press Enter The extracted file co...

Страница 78: ...n off all connected peripherals turn off system power and disconnect the AC power cord 2 Remove the access cover and expose the server board For instructions see the product guide accompanying your system 3 Locate the server board jumpers See Figure 30 on page 91 4 Move the Recovery Boot RCVRY BOOT jumper from its normal position to the BIOS recovery position see Figure 30 and Table 10 on page 91 ...

Страница 79: ... few minutes 9 Once the operational code updates and verifies press any key to continue Then press ESC to exit the program 10 Shut the system down and remove any diskettes in the system 11 Disconnect the AC power cord from the system and wait 60 seconds 12 Reconnect the AC power cord and power up the system FRU SDR Load Utility Description The Field Replacement Unit FRU and Sensor Data Record SDR ...

Страница 80: ...nd line function can consist of two parameters Example cfg filename cfg Invalid parameters cause an error message and exit the program You can use either a slash or a minus sign to specify command line options Use the p and flags with any of the other options Displaying a Given Area When the utility is run with the d FRU or d SDR command line flag information about each area is read from memory an...

Страница 81: ...ge Area After the utility validates the header area of the supplied SDR file it updates the SDR repository area Before programming the utility clears the SDR repository area The utility filters all tagged SDRs depending on the product configuration set in the configuration file Untagged SDRs come automatically programmed The utility also copies all written SDRs to the SDR TMP file it contains an i...

Страница 82: ...82 Intel Server Board SCB2 Product Guide ...

Страница 83: ... server board q Are all jumper settings on the server board correct q Are all jumper and switch settings on add in boards and peripheral devices correct To check these settings refer to the manufacturer s documentation that comes with them If applicable ensure that there are no conflicts for example two add in boards sharing the same interrupt q Are all DIMMs installed correctly q Are all peripher...

Страница 84: ...ions that are easy to correct however can also cause such problems Checklist q If you are running the software from a diskette try a new copy of the software q If you are running the software from a CD ROM disk try a different disk to see if the problem occurs on all disks q If you are running the software from a hard disk drive try running it from a diskette If the software runs correctly there m...

Страница 85: ... loads from the hard disk drive make sure there is no diskette in drive A Otherwise place a diskette containing the operating system files in drive A 5 Turn on the system If the power LED does not light see Power Light Does Not Light on page 86 6 If errors are encountered power off the system and remove all add in cards Monitoring POST See Power On Self Test POST on page 43 Verifying Proper Operat...

Страница 86: ...er for help Power Light Does Not Light Check the following q Is the system operating normally If so the power LED is probably defective or the cable from the front panel to the server board is loose q Are there other problems with the system If so check the items listed under System Cooling Fans Do Not Rotate Properly If all items are correct and problems persist contact your service representativ...

Страница 87: ...m persists the video monitor may be faulty or it may be the incorrect type Contact your service representative or authorized dealer for help System Cooling Fans Do Not Rotate Properly If the system cooling fans are not operating properly system components could be damaged Check the following q Is AC power available at the wall outlet q Is the system power cord properly connected to the system and ...

Страница 88: ...lowing q Are the power and signal cables to the CD ROM drive properly installed q Are all relevant switches and jumpers on the drive set correctly q Is the drive properly configured q Is the onboard IDE controller enabled Cannot Connect to a Server q Make sure you are using the drivers that are shipped on the system Configuration Software CD for the onboard network controller q Make sure the drive...

Страница 89: ...controller stopped working when an add in adapter was installed q Make sure the cable is connected to the port from the onboard network controller q Make sure your PCI BIOS is current q Make sure the other adapter supports shared interrupts Also make sure your operating system supports shared interrupts OS 2 does not q Try reseating the add in adapter The add in adapter stopped working without app...

Страница 90: ... is with the copy you are using q Make sure all cables are installed correctly q Verify that the server board jumpers are set correctly See Chapter 5 q If other software runs correctly on the system contact your vendor about the failing software If the problem persists contact the software vendor s customer service representative for help Bootable CD ROM Is Not Detected Check the following q Is th...

Страница 91: ... these pins are not jumpered BMC boot block is erasable and programmable at next reset CMOS CLR B If these pins are jumpered the CMOS settings are cleared These pins should not be jumpered for normal operation PSWD CLR C If these pins are jumpered the CMOS password is cleared These pins should not be jumpered for normal operation RCVRY BOOT D If these pins are jumpered the system will attempt BIOS...

Страница 92: ...ostic LED color string from the baseboard to those listed in the diagnostic LED decoder in the following tables the LEDs on the baseboard should be referenced when viewed by looking into the system from the back Reading the LEDs from left to right the Hi bit is located on the left Table 11 Post Codes Diagnostic LED Decoder G Green R Red A Amber Post Code MSB LSB Description 07h Off G G G Uncompres...

Страница 93: ... R Check point After CMOS Initialized 27h Off G A G Validate date and time in RTC F4h R A R R Load Micro Code To All CPUs F6h R A A R Scan SMBIOS GPNV areas 15h Off G Off A 8254 Timer Test on Channel 2 15h Off G Off A Enable 8042 15h Off G Off A Keyboard Reset 26h Off G A Off Initialize LCD if supported 28h G Off R Off Set Video Mode Initialization before setting the video mode is complete Configu...

Страница 94: ...for stuck keys Issuing the keyboard reset command next 81h R Off Off G Keyboard Interface Test A keyboard reset error or stuck key was found Issuing the keyboard controller interface test command next 82h R Off G Off Check Stuck Key Enable Keyboard The keyboard controller interface test completed Writing the command byte and initializing the circular buffer next 83h R Off G G Disable parity NMI Th...

Страница 95: ...rror manager displays and logs POST errors Waits for user input for certain errors Execute setup 8Bh A Off G G Set Base Expansion Memory Size 8Ch A G Off Off Adjust Setup Programming the Setup options next A5h R G R G Set Display Mode A7h R G A G OEM Patch 12 A7h R G A G Build SMBIOS table and MP tables A7h R G A G Program hotkey and timeout settings in keyboard controller A7h R G A G Processor in...

Страница 96: ...96 Intel Server Board SCB2 Product Guide ...

Страница 97: ...ation Radiated Conducted Emissions USA ICES 003 Class A Radiated Conducted Emissions Canada CISPR 22 Class A Radiated Conducted Emissions International EN55022 Class A Radiated Conducted Emissions European Union EN55024 Immunity European Union CE EMC Directive 89 336 EEC European Union GOST R 29216 91 Radiated Conducted Emissions Russia GOST R 50628 95 Immunity Russia VCCI Class A Radiated Conduct...

Страница 98: ...ion of Conformity This product has been tested to AS NZS 3548 and complies with ACA emission requirements The product has been marked with the C Tick Mark to illustrate its compliance Ministry of Economic Development New Zealand Declaration of Conformity This product has been tested to AS NZS 3548 and complies with New Zealand s Ministry of Economic Development emission requirements BSMI Taiwan Th...

Страница 99: ...nformation when you run the SSU Item Manufacturer Name and Model Number Serial Number Date Installed System Server Board Primary Processor Speed and Cache Secondary Processor Speed and Cache Video Display Keyboard Mouse Diskette Drive A Diskette Drive B Tape Drive CD ROM Drive Hard Disk Drive 1 Hard Disk Drive 2 Hard Disk Drive 3 Hard Disk Drive 4 Hard Disk Drive 5 continued ...

Страница 100: ...100 Intel Server Board SCB2 Product Guide Equipment Log continued Item Manufacturer Name and Model Number Serial Number Date Installed ...

Страница 101: ...ries per slot therefore ensure that adequate cooling is available in the target slot especially in an expansion slot dissipating more than 10 Watts Calculating Power Consumption The total combined wattage for the system configuration must be less than the output of your power supply Use the two worksheets in this section to calculate the power used by your server boards For current and voltage req...

Страница 102: ...evel Device 3 3 V 5 V 5 V Standby 12 V 12 V Server board 3 0 A 3 0 A 7 A 0 0 A 0 0 A Primary Processor Secondary Processor Memory six DIMMs Full Height PCI riser slot see note 1 PCI slot 1 PCI slot 2 PCI slot 3 Low Profile PCI riser slot see note 1 PCI slot 1 PCI slot 2 PCI slot 3 Server Board Current SUBTOTALS System Components see note 2 Total Current Note 1 Number of PCI cards depends on system...

Страница 103: ...he total wattage for each voltage level 3 Add the total wattage for each voltage level to arrive at a total combined power usage on the power supply Table 13 Power Usage Worksheet 2 Voltage level and total current V X A W Total Watts for each voltage level 3 3 V X ______ A ________ W 5 V X ______ A ________ W 5 V X ______ A ________ W 12 V X ______ A ________ W 12 V X ______ A ________ W Total Com...

Страница 104: ...104 Intel Server Board SCB2 Product Guide ...

Страница 105: ...BIOS update 77 BMC LAN Alert Dialog 68 Boot Device Priority submenu configuring in BIOS Setup 52 Boot menu configuring BIOS Setup 52 boot sequence booting without keyboard 19 changing permanently 54 changing priority 42 changing temporarily 53 setting in Setup 19 booting cold 83 BSP 92 bus termination requirements SCSI devices 11 C Caution avoid damaging jumpers when changing 32 avoid touching pro...

Страница 106: ...ialization 92 93 Integrated Peripheral submenu configuring in BIOS Setup 48 intrusion detection 17 jumpers do not damage when changing 32 keyboard compatibility 14 lockout timer seting in SCU 14 L LCD 93 lithium backup battery disposing of safely 39 installing 40 removing 39 M memory capacity 7 DIMM requirements 10 video amount 7 what type to install 7 Memory 10 94 95 Message 94 mouse compatibilit...

Страница 107: ... SCU administrative password limits access to 19 inactivity lockout timer 14 software locking feature 17 SDR Manager Add in 64 secure mode 18 affects boot sequence 19 enter by setting passwords 18 no booting from diskette without password 18 using hot keys to enter 42 security 17 18 alarm switches 17 boot sequence 19 enabling disabling floppy writes 18 locking mouse keyboard with timer 14 19 passw...

Страница 108: ... 38 Timeout 94 timer keyboard or mouse inactive 14 lockout inactivity setting in SCU 14 U USB See also Universal Serial Bus 93 user password 17 limit access to using system 19 utilities BIOS Setup 42 43 BIOS update 42 Emergency Management Port EMP Console 42 firmware update 42 Firmware update 79 FRUSDR load 42 FRUSDR load utility 79 SCSISelect 54 Setup See BIOS Setup SSU 42 V W video blanking for ...

Отзывы: