background image

HX3510-G, HX5510, HX5510-C, HX7510
Installation and Service Guide

Machine Type:

8695

Содержание HX3510-G

Страница 1: ...HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide Machine Type 8695 ...

Страница 2: ...y Information document and the Safety Information and Environmental Notices and User Guide documents on the Documentation CD Third Edition March 2017 Copyright Lenovo 2016 2017 LIMITED AND RESTRICTED RIGHTS NOTICE If data or software is delivered pursuant to a General Services Administration GSA contract use reproduction or disclosure is subject to restrictions set forth in Contract No GS 35F 0592...

Страница 3: ... 3 Troubleshooting 51 Start here 51 Diagnosing a problem 51 Undocumented problems 53 Service bulletins 53 Checkout procedure 54 About the checkout procedure 54 Performing the checkout procedure 54 Diagnostic tools 55 Power supply LEDs 57 System pulse LEDs 58 PCI riser card LEDs 59 Event logs 59 POST 61 Dynamic System Analysis 61 Automated service request call home 64 Electronic Service Agent 64 Er...

Страница 4: ...e dedicated slotless HBA controller 147 Replacing the dedicated slotless HBA controller 148 Removing an adapter 149 Replacing an adapter 152 Removing an EIA assembly 157 Replacing an EIA assembly 167 Removing a hot swap ac power supply 179 Replacing a hot swap ac power supply 181 Removing the 2 5 inch hot swap hard disk drive backplane 184 Replacing the 2 5 inch hot swap hard disk drive backplane ...

Страница 5: ...187 DSA tape drive test results 1201 Test results for the DSA tape drive test 1201 Appendix D Getting help and technical assistance 1207 Before you call 1207 Using the documentation 1208 Getting help and information from the World Wide Web 1208 How to send DSA data 1208 Creating a personalized support web page 1208 Software service and support 1209 Hardware service and support 1209 Taiwan product ...

Страница 6: ...iv HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 7: ...en Ennen kuin asennat tämän tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de sécurité Vor der Installation dieses Produkts die Sicherheitshinweise lesen Prima di installare questo prodotto leggere le Informazioni sulla Sicurezza Les sikkerhetsinformasjonen Safety Information før du installerer dette produktet Antes de instalar este produto le...

Страница 8: ...ution statement are in the Safety Information document under Statement 1 Be sure to read all caution and danger statements in this documentation before you perform the procedures Read any additional safety information that comes with your system or optional device before you install the device Statement 1 DANGER Electrical current from power telephone and communication cables is hazardous To avoid...

Страница 9: ... the lithium battery use only Part Number 33F8354 or an equivalent type battery recommended by the manufacturer If your system has a module containing a lithium battery replace it only with the same module type made by the same manufacturer The battery contains lithium and can explode if not properly used handled or disposed of Do not Throw or immerse into water Heat to more than 100 C 212 F Repai...

Страница 10: ... A Laser de Classe 1 Statement 4 CAUTION Use safe practices when lifting 18 kg 39 7 lb 32 kg 70 5 lb 55 kg 121 2 lb Statement 5 CAUTION The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove all electrical current from the device ensure that all power...

Страница 11: ...upply or any part that has the following label attached Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serviceable parts inside these components If you suspect a problem with one of these parts contact a service technician Statement 12 CAUTION The following label indicates a hot surface nearby Statement 26 CAUTION Do not place...

Страница 12: ...e leveling pads on the rack cabinet Always install stabilizer brackets on the rack cabinet Always install servers and optional devices starting from the bottom of the rack cabinet Always install the heaviest devices in the bottom of the rack cabinet x HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 13: ...loads that require large amounts of data storage such as data collection via Splunk data replication and backup The HX5510 as shown below contains eight 3 5 inch drives with two SSDs and six HDDs The hard drives can be 2 4 6 or 8 TB A variation of the HX5510 named the HX5510 C model type AC2 can only be used for cold data storage and cannot perform hyper converged computation Externally the HX5510...

Страница 14: ...ications about new technical documents search for information and downloads and access various administrative services If you participate in the client reference program you can share information about your use of technology best practices and innovative solutions build a professional network and gain visibility for your business For more information about the client reference program see http www...

Страница 15: ...are Microsoft Windows XP Windows 2000 or Red Hat Linux 100 MHz microprocessor 32 MB of RAM Adobe Acrobat Reader 3 0 or later or xpdf which comes with Linux operating systems The Documentation CD Use the Documentation Browser to browse the contents of the CD read brief descriptions of the documents and view documents using Adobe Acrobat Reader or xpdf The Documentation Browser automatically detects...

Страница 16: ...d documentation This Installation and Service Guide contains general information about the server including how to set up and cable the server how to configure the server and information to help you solve problems yourself and information for service technicians The following documentation also comes with the server Environmental Notices and User Guide This document is in PDF format on the Documen...

Страница 17: ...x Documentation CD Each statement is numbered for reference to the corresponding statement in your language in the Safety Information document The following notices and statements are used in this document Note These notices provide important tips guidance or advice Important These notices provide information or advice that might help you avoid inconvenient or problem situations Attention These no...

Страница 18: ...d to the IMM2 1 functions Optional serial port Hard disk drive expansion bays depending on the model 2 5 inch models Supports eight or twenty four 2 5 inch hot swap SATA hard disk drive bays 3 5 inch models Supports eight 3 5 inch hot swap SAS hard disk drive bays HBA controllers N2215 SAS SATA HBA supporting one or three depending on model Video controller integrated into IMM2 1 Matrox G200eR2 No...

Страница 19: ...eatures installed and the power management optional features in use 2 The noise emission level stated is the declared upper limit sound power level in bels for a random sample of machines All measurements are made in accordance with ISO 7779 and reported in conformance with ISO 9296 Actual sound pressure levels in a given location might exceed the average values stated because of room reflections ...

Страница 20: ...ors including the number of racks in the installation the size materials and configuration of the room the noise levels from other equipment the room ambient temperature and pressure and employees location in relation to the equipment Heat output Approximate heat output Minimum configuration 525 45 Btu per hour AC 154 watts Maximum configuration 6667 Btu per hour AC 1954 watts Environment The Leno...

Страница 21: ...l that go into the datacenter all mobile furnishings and equipment will be made of conductive or static dissipative materials During maintenance on any hardware a properly functioning wrist strap must be used by any personnel who contacts IT equipment 5 C hr 41 F hr for data centers employing tape drives and 20 C hr 68 F hr for data centers employing disk drives Chassis is removed from original sh...

Страница 22: ...troduces features and technologies the server uses and provides Dynamic System Analysis DSA The server comes with the Dynamic System Analysis DSA Preboot diagnostic program stored in the integrated USB memory on the server DSA collects and analyzes system information to aid in diagnosing server problems as well as offering a rich set of diagnostic tests of the major components of the server DSA cr...

Страница 23: ...rmation Model CIM Web browser Some of the features that are unique to the IMM are enhanced performance higher resolution remote video expanded security options and Feature on Demand enablement for hardware and firmware options For additional information see Using the integrated management module on page 40 and the Integrated Management Module II User s Guide at http publib boulder ibm com infocent...

Страница 24: ...he fans in the server enables continued operation if one of the fans fails Note You cannot mix different wattages and different 80 plus efficiency level of power supplies in the server Systems management capabilities The server comes with an IMM2 1 When the IMM is used with the systems management software that comes with the server you can manage the functions of the server locally and remotely Th...

Страница 25: ...sors hard disk drives solid state drives power supplies and fans Memory mirroring and memory sparing support Memory error correcting code and parity test Memory down sizing non mirrored memory After a restart of the server after the memory controller detected a non mirrored uncorrectable error and the memory controller cannot recover operationally the IMM logs the uncorrectable error and informs P...

Страница 26: ...h the Inter Integrated Circuit IC protocol bus Uncorrectable error UE detection Upgradeable POST Unified Extensible Firmware Interface UEFI diagnostics IMM firmware and read only memory ROM resident code locally or over the LAN Vital product data VPD on microprocessors system board power supplies and SAS SATA hot swap hard disk drive or solid state drive backplane Wake on LAN capability Server con...

Страница 27: ...es that the drive has failed Operator information panel This panel contains controls and LEDs that provide information about the status of the server For information about the controls and LEDs on the operator information panel see Operator information panel on page 15 USB connectors Connect a USB device such as a USB mouse or keyboard to any of these connectors Operator information panel The foll...

Страница 28: ...low LED is lit it indicates that a system error has occurred Check the event log for additional information See Event logs on page 59 for more information about event logs System error LED When this yellow LED is lit it indicates that a system error has occurred A system error LED is also on the rear of the server An LED on the LCD system information display panel if available the operator informa...

Страница 29: ... scroll to the right in the main menu to location and select the system information that you want displayed The following is an illustration of the LCD system information display panel menu options flow Reset IMM to default settings Request IMM Hard Reset Request IMM Soft Reset Clear CMOS Reset IMM to default settings Figure 11 LCD system information display panel menu options flow The following i...

Страница 30: ... error occurs the LCD display panel displays the number of errors that have occurred If no errors occur the no error menu will be available for navigation To move within the menu options use the Scroll up or Scroll down buttons then the Select button to enter a submenu set The LCD system information display panel displays the following types of information about the server IMM system error log SEL...

Страница 31: ...ss System environmental information Ambient temperature CPU temperature AC input voltage Estimated power consumption Rear view The following illustration shows the connectors on the rear of the appliance Figure 13 Rear view HX3510 G models Figure 14 Rear view HX5510 and HX5510 C models Chapter 1 The Lenovo Converged HX Series server 19 ...

Страница 32: ... A dedicated management network provides additional security by physically separating the management network traffic from the production network You can use the Setup Utility to configure the server to use a dedicated systems management network or a shared network See Using the Setup Utility in the Problem Determination and Service Guide for more information Ethernet connectors Use either of these...

Страница 33: ...e system During typical operation both the ac and dc power LEDs are lit Power supply error LED When the power supply error LED is lit it indicates that the power supply has failed Note Power supply 1 is the default primary power supply If power supply 1 fails you must replace the power supply immediately Power on LED When this LED is lit and not flashing it indicates that the server is turned on T...

Страница 34: ...Slot 6 Slot 7 Slot 8 Slot 4 Slot 5 000000 000000 000000 000000 000000 000000 Figure 17 PCI riser card adapter expansion slot locations Server components The following illustration shows the major components in the server The illustrations in this document might differ slightly from your hardware 22 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 35: ...0000 0000 0000 0000 0000 2 5 inch advanced operation panel assembly Figure 18 Server components Blue on a component indicates touch points where you can grip the component to remove it from or install it in the server open or close a latch and so on Orange on a component or an orange label on or near a component indicates that the component can be hot swapped which means that if the server and ope...

Страница 36: ...roprocessor 1 DIMM connectors NMI button Battery PCI slot connector 5 PCI slot connector 4 PCI riser connector 1 Power supply connector SAS SATA backplane power config connector 3 SAS SATA backplane power config connector 2 SAS SATA backplane power config connector 1 Video card power connector 1 Serial connector SD adapter connector SATA 0 connector Figure 19 System board internal connectors Syste...

Страница 37: ...net 4 connector USB connectors System management dedicated Figure 20 System board external connectors System board optional device connectors The following illustration shows the connectors on the system board for the optional devices Chapter 1 The Lenovo Converged HX Series server 25 ...

Страница 38: ...rocessor 2 Microprocessor 1 DIMM 1 6 Figure 21 System board optional device connectors System board switches jumpers and buttons The following illustration shows the location of the switches jumpers and buttons on the server Note If there is a clear protective sticker on the top of the switch blocks you must remove and discard it to access the switches 26 HX3510 G HX5510 HX5510 C HX7510 Installati...

Страница 39: ...2 Normal default Pins 2 and 3 Clears the real time clock RTC registry J15 UEFI boot backup jumper Pins 1 and 2 Normal default Loads the primary server firmware ROM page Pins 2 and 3 Loads the secondary backup server firmware ROM page Notes 1 If no jumper is present the server responds as if the pins are set to the default 2 Changing the position of the UEFI boot backup jumper J15 from pins 1 and 2...

Страница 40: ...ff the server then disconnect all power cords and external cables Review the information in Safety on page v Removing and replacing guidelines on page 101 Handling static sensitive devices on page 103 and Turning off the server on page 31 2 Any system board switch or jumper block that is not shown in the illustrations in this document are reserved The following table describes the functions of the...

Страница 41: ...D Slot 4 error LED DIMM 19 24 error LED Fan1 error LED Fan 2 error LED Fan 3 error LED Fan 4 error LED Fan 5 error LED Fan 6 error LED Figure 23 System board LEDs Riser card adapter expansion slot connectors The following illustration shows the respective expansion slot connectors Riser card assembly 1 for HX3510 G and HX7510 PCI riser card assembly Slot 1 PCIe x16 Slot 3 PCIe x8 Figure 24 PCI ris...

Страница 42: ...ive backplanes The following illustration shows the respective 2 5 inch 3 5 inch hot swap hard disk drive backplanes 2 5 inch HDD hot swap backplane Figure 26 2 5 inch hot swap hard disk drive backplane 3 5 inch HDD hot swap backplane with 8 drives Figure 27 3 5 inch hot swap hard disk drive backplane 30 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 43: ... memory physical or logical is installed some memory is reserved for various system resources and is unavailable to the operating system The amount of memory that is reserved for system resources depends on the operating system the configuration of the server and the configured PCI options 2 Ethernet 1 connector supports Wake on LAN feature 3 When you turn on the server with the graphical adapters...

Страница 44: ... supports this feature If the operating system stops functioning you can press and hold the power control button for more than 4 seconds to turn off the server The server can be turned off by Wake on LAN feature with the following limitation Note When you install any PCI adapter the power cords must be disconnected from the power source before you remove the PCI Express riser card assembly Otherwi...

Страница 45: ...Pack contains an integration tested bundle of online firmware and device driver updates for your server Use UpdateXpress System Pack Installer to acquire and apply UpdateXpress System Packs and individual firmware and device driver updates For additional information and to download the UpdateXpress System Pack Installer go to the ToolsCenter for System x and BladeCenter at https support lenovo com...

Страница 46: ...rver setup time from days to minutes particularly for larger deployments For information about this tool see http www ibm com support entry portal docdisplay brand 5000008 Indocid TOOL FASTSET Integrated management module II IMM2 Use the IMM2 for configuration to update the firmware and sensor data record field replaceable unit SDR FRU data and to remotely manage a network For information about us...

Страница 47: ...nd I O ports Set the date and time Set and change passwords Set the startup characteristics of the server and the order of startup devices Set and change settings for advanced hardware features View set and change settings for power management features View and clear error logs Change interrupt request IRQ settings Resolve configuration conflicts Starting the Setup Utility Use this information to ...

Страница 48: ...essor settings Memory Select this choice to view or change the memory settings Devices and I O Ports Select this choice to view or change assignments for devices and input output I O ports You can configure the serial ports configure remote console redirection enable or disable PCI slots and video controller If you disable a device it cannot be configured and the operating system will not be able ...

Страница 49: ...face on IMM The default is Enable Network Configuration Select this choice to view the system management network interface port the IMM MAC address the current IMM IP address and host name define the static IMM IP address subnet mask and gateway address specify whether to use the static IP address or have DHCP assign the IMM IP address save the network changes and reset the IMM Reset IMM to Defaul...

Страница 50: ...le you can define a startup sequence that checks for a disc in the CD RW DVD drive then checks the hard disk drive and then checks a network adapter This choice is on the full Setup Utility menu only Boot Manager Select this choice to view add delete or change the device boot priority boot from a file select a one time boot or reset the boot order to the default setting System Event Logs Select th...

Страница 51: ... Select this choice to exit from the Setup Utility If you have not saved the changes that you have made in the settings you are asked whether you want to save the changes or exit without saving them Using the Boot Manager The Boot Manager program is a built in menu driven configuration utility program that you can use to temporarily redefine the first startup device without changing settings in th...

Страница 52: ...r Automatic Server Restart ASR when POST is not complete or the operating system hangs and the operating system watchdog timer times out The IMM might be configured to watch for the operating system watchdog timer and reboot the system after a timeout if the ASR feature is enabled Otherwise the IMM allows the administrator to generate a nonmaskable interrupt NMI by pressing an NMI button on the LC...

Страница 53: ...e screen capture features are integrated functions of the IMM2 The remote presence feature provides the following functions Remotely viewing video with graphics resolutions up to 1600 x 1200 at 75 Hz regardless of the system state Remotely accessing the server using the keyboard and mouse from a remote client Uploading a diskette image to the IMM memory and mapping it to the server as a virtual dr...

Страница 54: ... on the screen for only a few seconds You must press F1 quickly If you have set both a power on password and an administrator password you must type the administrator password to access the full Setup Utility menu Step 3 From the Setup Utility main menu select System Settings Step 4 On the next screen select Integrated Management Module Step 5 On the next screen select Network Configuration Step 6...

Страница 55: ...nd mode You do not have to set any jumpers or configure the controllers However you must install a device driver to enable the operating system to address the controllers To find device drivers and information about configuring the Ethernet controllers go to http www lenovo com support Lenovo ToolsCenter Suite CLI program The Lenovo ToolsCenter Suite CLI program is a collection of server managemen...

Страница 56: ...lsCenter Suite CLI OneCLI to update the UUID in the UEFI based server OneCLI is an online tool that supports several operating systems Make sure that you download the version for your operating system You can download OneCLI from the Lenovo Web site To download OneCLI and update the UUID do the following Note Changes are made periodically to the Lenovo Web site The actual procedure might vary slig...

Страница 57: ...icted You do not need to specify a value for access_method when you use this access method Example onecli config set SYSTEM_PROD_DATA SysInfoUUID uuid_value The KCS access method uses the IPMI KCS interface This method requires that the IPMI driver be installed Some operating systems have the IPMI driver installed by default OneCLI provides the corresponding mapping layer For more details see the ...

Страница 58: ...ing Note Changes are made periodically to the Lenovo Web site The actual procedure might vary slightly from what is described in this document Step 1 Go to https support lenovo com us en documents LNVO TCLI Then find and download the OneCLI version for your operating system Step 2 OneCLI sets the DMI in the IMM2 Select one of the following methods to access the IMM2 to set the DMI Online from the ...

Страница 59: ...fault values onecli config set SYSTEM_PROD_DATA SysInfoProdName m t_model onecli config set SYSTEM_PROD_DATA SysInfoSerialNum s n onecli config set SYSTEM_PROD_DATA SysEncloseAssetTag asset_tag Online KCS access unauthenticated and user restricted You do not need to specify a value for access_method when you use this access method The KCS access method uses the IPMI KCS interface This method requi...

Страница 60: ...ble tools Step 5 Continue with steps 6 through 10 in the next section Configuring the HX Series appliance The section contains configuration procedures that are used in one or more of the hardware replacement procedures described in Chapter 5 Removing and replacing components on page 101 Step 6 Update the appliance name The DMI SMBIOS string for the Lenovo Converged HX Series appliance is the same...

Страница 61: ... the power performance bias Use the OneCLI system tool or other means to set the operating mode onecli config set OperatingModes ChooseOperatingMode Custom Mode Power performance bias This option allows the OS hypervisor to control the node power Many customers prefer this setting as it saves on OPEX Use the OneCLI system tool or other means to set the power performance bias to OS Controlled onecl...

Страница 62: ...50 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 63: ...lem occurred If any hardware software or firmware was changed before the problem occurred if possible reverse those changes This might include any of the following items Hardware components Device drivers and firmware System software UEFI firmware System input power or network connections Step 2 View the light path diagnostics LEDs and event logs The server is designed for ease of diagnosis of har...

Страница 64: ...e information about the Bootable Media Creator see https support lenovo com us en documents LNVO BOMC Be sure to separately install any listed critical updates that have release dates that are later than the release date of the UpdateXpress System Pack or UpdateXpress image see step b b Install manual system updates 1 Determine the existing code levels In DSA click Firmware VPD to view system firm...

Страница 65: ...ingle problem might cause multiple symptoms Follow the troubleshooting procedure for the most obvious symptom If that procedure does not diagnose the problem use the procedure for another symptom if possible If the problem remains contact an approved warranty service provider for assistance with additional problem determination and possible hardware replacement To open an online service request go...

Страница 66: ...luster two or more servers sharing external storage devices If it is part of a cluster you can run all diagnostic programs except the ones that test the storage unit that is a hard disk drive in the storage unit or the storage adapter that is attached to the storage unit The failing server might be part of a cluster if any of the following conditions is true You have identified the failing server ...

Страница 67: ...stic programs on page 62 If DSA reports an error follow the instructions in Appendix C DSA diagnostic test results on page 1051 If DSA does not report an error but you still suspect a problem see Solving undetermined problems on page 84 Diagnostic tools The section introduces available tools to help you diagnose and solve hardware related problems LCD system information display panel available on ...

Страница 68: ...vent logs for ServeRAID controllers and service processors Installed hardware including PCI and USB information LCD system information display panel if available status Microprocessor input output hub and UEFI error logs Network interfaces and settings Option card driver and firmware information RAID controller configuration Service processor integrated management module status and configuration S...

Страница 69: ... power LED green Power supply error LED yellow System power LED System error LED Locator batton LED 000000 000000 000000 000000 000000 000000 Figure 28 AC power supply LEDs The following table describes the problems that are indicated by various combinations of the power supply LEDs on an ac power supply and suggested actions to correct the detected problems AC power supply LEDs AC DC Error Descri...

Страница 70: ...supply is not fully seated On Off On The power supply has failed Replace the power supply On On Blinking On The power supply has failed Replace the power supply System pulse LEDs The following LEDs are on the system board and monitor the system power on and power off sequencing and boot progress see System board LEDs on page 28 for the location of these LEDs Table 5 System pulse LEDs LED Descripti...

Страница 71: ... Setup Utility and through the Dynamic System Analysis DSA program as IPMI event log The system event log is limited in size When it is full new entries will not overwrite existing entries therefore you must periodically clear the system event log through the Setup Utility When you are troubleshooting an error you might have to save and then clear the system event log to make the most recent event...

Страница 72: ... operating system event logs or the merged OneCLI log You can also use DSA Preboot to view these logs although you must restart the server To install OneCLI or check for and download a later version of OneCLI image go to https support lenovo com us en documents LNVO CENTER If IPMItool is installed in the server you can use it to view the system event log Most recent versions of the Linux operating...

Страница 73: ...error log is automatically cleared each time the server is restarted Step 1 Turn on the server Step 2 When the prompt F1 Setup is displayed press F1 If you have set both a power on password and an administrator password you must type the administrator password to view the event logs Step 3 To clear the IMM system event log select System Event Logs Clear System Event Log then press Enter twice POST...

Страница 74: ...rating system you must restart the server to run it It is provided in the flash memory on the server or you can create a bootable media such as a CD DVD ISO USB or PXE using the ToolsCenter Bootable Media Creator BoMC For more details see the BoMC User Guide at https support lenovo com us en documents LNVO BOMC In addition to the capabilities of the other editions of DSA DSA Preboot includes diagn...

Страница 75: ...n this happens correct the cause of the first error message The other error messages usually will not occur the next time you run the diagnostic programs If the server stops during testing and you cannot continue restart the server and try running the DSA Preboot diagnostic programs again If the problem remains replace the component that was being tested when the server stopped Diagnostic text mes...

Страница 76: ...229 and Appendix C DSA diagnostic test results on page 1051 for more information Troubleshooting by symptom Use the troubleshooting tables to find solutions to problems that have identifiable symptoms If you cannot find a solution to the problem in these tables see Appendix C DSA diagnostic test results on page 1051 for information about testing the server and Running the DSA Preboot diagnostic pr...

Страница 77: ...d yellow hard disk drive status LED is lit Replace the failed hard disk drive see Replacing a front HDD SSD on page 104 A newly installed hard disk drive is not recognized 1 Make sure that the installed hard disk drive is supported 2 Observe the associated yellow hard disk drive status LED If the LED is lit it indicates a drive fault 3 If the LED is lit remove the drive from the bay wait 45 second...

Страница 78: ... drive does not rebuild 1 Make sure that the hard disk drive is recognized by the adapter the green hard disk drive activity LED is flashing 2 Review the SAS SATA adapter documentation to determine the correct configuration parameters and settings A green hard disk drive activity LED does not accurately represent the actual state of the associated drive If the green hard disk drive activity LED do...

Страница 79: ...on applies check the system error log or IMM system event log see Event logs on page 59 Keyboard mouse or USB device problems Use the troubleshooting tables to find solutions to problems that have identifiable symptoms Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved If an action step is preceded by Trained technician only that ste...

Страница 80: ...is no memory mismatch when the server is at the minimum memory configuration 2 Reseat the DIMMs and then restart the server 3 Check the POST error log If a DIMM was disabled by a systems management interrupt SMI replace the DIMM If a DIMM was disabled by the user or by POST reseat the DIMM then run the Setup Utility and enable the DIMM 4 Check that all DIMMs are initialized in the Setup Utility th...

Страница 81: ...hat have identifiable symptoms Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved If an action step is preceded by Trained technician only that step must be performed only by a trained technician Go to the support website at http www lenovo com support to check for technical information hints tips and new device drivers or to submit ...

Страница 82: ...his is normal operation while the system loads 3 Make sure that The server is turned on If there is no power to the server see Power problems on page 72 The monitor cables are connected correctly The monitor is turned on and the brightness and contrast controls are adjusted correctly 4 Make sure that the correct server is controlling the monitor if applicable 5 Make sure that damaged server firmwa...

Страница 83: ...ion Move the device and the monitor at least 305 mm 12 in apart and turn on the monitor Notes a To prevent diskette drive read write errors make sure that the distance between the monitor and any external diskette drive is at least 76 mm 3 in b Non Lenovo monitor cables might cause unpredictable problems 2 Reseat the monitor cable 3 Replace the components listed in step 2 one at a time in the orde...

Страница 84: ...eshooting tables to find solutions to problems that have identifiable symptoms Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved If an action step is preceded by Trained technician only that step must be performed only by a trained technician Go to the support website at http www lenovo com support to check for technical information...

Страница 85: ...wer supply do not indicate a problem The microprocessors are installed in the correct sequence 5 Reseat the following components a Operator information panel connector b Power supplies 6 Replace the components listed in step 5 one at a time in the order shown restarting the server each time 7 If you just installed an optional device remove it and restart the server If the server now starts you mig...

Страница 86: ... and Replacing the system board on page 226 4 Reinstall the Processor then restarting the server If the Pwr rail C error has been recorded in the system event log again the Processor that you just reinstalled is defective Replace the defective component Trained technician only Microprocessor 2 see Removing a microprocessor and heat sink on page 207 and Replacing a microprocessor and heat sink on p...

Страница 87: ...he Pwr rail G error has been recorded in the system event log 1 Disconnect the server power cords 2 Remove the following components if the Pwr rail G error has been recorded in the system event log Raid Card in Raid slot Optional adapter if one is present in PCIe slot 4 Optional adapter if one is present in PCIe slot 5 Optional adapter if one is present installed in riser card assembly 1 Riser car...

Страница 88: ...restarting the server If the Pwr rail G error has been recorded in the system event log again the Processor that you just reinstalled is defective Replace the defective Processor Trained technician only Microprocessor 1 See Removing a microprocessor and heat sink on page 207 and Replacing a microprocessor and heat sink on page 213 The Pwr rail H error has been recorded in the system event log 1 Di...

Страница 89: ...er cords 2 Remove Fans 1 through 6 if Pwr rail J error has been recorded in the system event log 3 Restart the server If the Pwr rail J error has been recorded in the system event log again trained technician only replace the system board see Removing the system board on page 223 and Replacing the system board on page 226 4 Reinstall the Fans one at a time restarting the server each time If the Pw...

Страница 90: ...g again the component that you just reinstalled is defective Replace the defective component Optional PCI adaptor power cable if one is present PCI Riser Card Assembly where the optional PCI adaptor power cable correlated PCI adaptor is installed Optional PCI adaptor power cable correlated PCI adaptor The Pwr rail M error has been recorded in the system event log 1 Disconnect the server power cord...

Страница 91: ...blems Use the troubleshooting tables to find solutions to problems that have identifiable symptoms Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved If an action step is preceded by Trained technician only that step must be performed only by a trained technician Go to the support website at http www lenovo com support to check for t...

Страница 92: ... Windows operating systems The operating system cannot be installed the option is not available Make sure that the server supports the operating system If it does either no logical drive is defined SCSI RAID servers or the ServerGuide System Partition is not present Run the ServerGuide program and make sure that setup is complete Software problems Follow the suggested actions in the order in which...

Страница 93: ...f an overcurrent condition To diagnose a power problem use the following general procedure Step 1 Turn off the server and disconnect all power cords Step 2 Check for loose cables in the power subsystem Also check for short circuits for example if a loose screw is causing a short circuit on a circuit board Step 3 Check the lit LEDs on the light path diagnostics panel Step 4 If the check log LED on ...

Страница 94: ...d assembly 1 PCIe Solid state drives PCIe Solid state drive backplane assembly USB devices LCD monitor connected to rear VGA port if one is present Pwr rail G error Raid Card in Raid slot Optional adapter if one is present in PCIe slot 4 Optional adapter if one is present in PCIe slot 5 Optional adapter if one is present installed in riser card assembly 1 Riser card assembly 1 Optional adapter if ...

Страница 95: ...nnect all ac power cords and turn on the server If the server starts successfully reseat the adapters and devices one at a time until the problem is isolated If the server does not start from the minimum configuration see Power supply LEDs on page 57 to replace the components in the minimum configuration one at a time until the problem is isolated Solving Ethernet controller problems The method th...

Страница 96: ...ed problems If Dynamic System Analysis DSA did not diagnose the failure or if the server is inoperative use the information in this section If you suspect that a software problem is causing failures continuous or intermittent see Software problems on page 80 Corrupted data in CMOS memory or corrupted UEFI firmware can cause undetermined problems To reset the CMOS data use the CMOS clear jumper J11...

Страница 97: ... symptom Does the server fail the diagnostic tests What occurs When Where Does the failure occur on a single server or on multiple servers Is the failure repeatable Has this configuration ever worked What changes if any were made before the configuration failed Is this the original reported failure Diagnostic program type and version level Hardware configuration print screen of the system summary ...

Страница 98: ...date package Note You can obtain a server update package from one of the following sources Download the server firmware update from the World Wide Web Contact your service representative To download the server firmware update package from the World Wide Web go to http www lenovo com support The flash memory of the server consists of a primary bank and a back up bank You must maintain a bootable UE...

Страница 99: ... firmware update by following the instructions that are in the firmware update package readme file Step 10 Turn off the server and disconnect all power cords and external cables and then remove the cover see Removing the top cover on page 116 Step 11 Move the UEFI boot backup jumper J15 from pins 2 and 3 back to the primary position pins 1 and 2 Step 12 Reinstall the cover see Replacing the top co...

Страница 100: ...Step 2 Perform the firmware update by following the instructions that are in the firmware update package readme file Step 3 Restart the server Step 4 At the firmware splash screen press F3 when prompted to restore to the primary bank The server boots from the primary bank Out of band method See the IMM2 documentation Integrated Management Module II User s Guide at http publib boulder ibm com infoc...

Страница 101: ... automatic or manual the Nx boot failure feature causes the server to revert to the default UEFI configuration and start the Setup Utility so that you can make the necessary corrections to the configuration and restart the server If the server is unable to successfully complete POST with the default configuration there might be a problem with the system board To specify the number of consecutive r...

Страница 102: ...90 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 103: ...ller is your responsibility If Lenovo acquires or installs a consumable component at your request you will be charged for the service See Structural parts and consumable parts on page 97 for the list of consumable parts Tier 1 customer replaceable unit CRU Replacement of Tier 1 CRUs is your responsibility If Lenovo installs a Tier 1 CRU at your request you will be charged for the installation Tier...

Страница 104: ...A assembly Front USB assembly Operator information panel assembly Front control panel assembly Riser cage filler 000000000 000000000 000000000 000000000 000000000 000000000 000000000 0000 0000 0000 0000 00000 00000 00000 Media cage 0000 0000 0000 0000 0000 0000 0000 0000 2 5 inch advanced operation panel assembly Figure 32 Server components The following table lists the part numbers for Tier 1 and...

Страница 105: ...50 v4 2 2GHz 30MB Cache 2400MHz 105W 12 core 00YD972 Microprocessor Intel Xeon Processor E5 2630 v4 2 2GHz 25MB Cache 2133MHz 85W 10 core Addl Intel Xeon Processor E5 2630 v4 2 2GHz 25MB Cache 2133MHz 85W 10 core 00YD974 Microprocessor Intel Xeon Processor E5 2620 v4 2 1GHz 20MB Cache 2133MHz 85W 8 core Addl Intel Xeon Processor E5 2620 v4 2 1GHz 20MB Cache 2133MHz 85W 8 core 00YD975 Memory module...

Страница 106: ...ED G3HS 01GR611 Hard disk drive 3 5 inch G2 hot swap near line SAS 7 2 K 12 Gbps 512e 2 TB 00FN189 Hard disk drive 3 5 inch G2 hot swap near line SAS 7 2 K 12 Gbps 512e 4 TB 00FN209 Hard disk drive 3 5 inch G2 hot swap near line SAS 7 2 K 12 Gbps 512e 6 TB 00FN229 Hard disk drive 3 5 inch G2 hot swap near line SAS 7 2 K 12 Gbps 512e 8 TB 00WH122 SSD 3 5 inch S3610 480GB SATA G3HS 00YK238 SSD 3 5 i...

Страница 107: ...00KF719 Cable SAS HD 350 mm vertical vertical 00KF704 Cable SAS HD 250 mm 00FK817 Cable SAS HD 550 mm 00FK811 Cable SAS HD 750 mm 00FK813 Cable SAS HD 450 450 mm 00FK845 Cable SAS HD 590 580 mm 00FK843 Cable SAS HD 525 635 mm 00FK839 Cable SAS HD 770 835 mm 00FK841 Cable SAS HD 950 905 mm 00FK847 Cable SAS HD 950 905 mm R A 00FK849 Cable front HDD 80 mm 00KC582 Cable front HDD 150 mm 00FK819 Cable...

Страница 108: ... OPA 100 Series Active Optical QSFP28 00WE073 Line cord 2 8 m 10A 100 250V C13 to IEC 320 C14 rack power cable 39M5377 Line cord 2 8 m 13A 125 10A 250V C13 to IEC 320 C14 rack power cable 39M5509 Power cord 00JY023 3 0 volt battery 33F8354 NVIDIA Tesla M60 GPU PCIe active 90Y2472 MISC KIT 00KF419 Gen II Universal slides kit 00KA593 Slide Gritstone 00MV990 Cable management arm CMA 00KA594 Label cha...

Страница 109: ...arts 3 Click Obtain maintenance parts then follow the instructions to order the part from the retail store If you need help with your order call the toll free number that is listed on the retail parts page or contact your local representative for assistance Power cords For your safety a power cord with a grounded attachment plug is provided to use with this product To avoid electrical shock always...

Страница 110: ...nisia Turkey Turkmenistan Ukraine Upper Volta Uzbekistan Vanuatu Vietnam Wallis and Futuna Yugoslavia Federal Republic of Zaire 39M5130 Denmark 39M5144 Bangladesh Lesotho Macao Maldives Namibia Nepal Pakistan Samoa South Africa Sri Lanka Swaziland Uganda 39M5151 Abu Dhabi Bahrain Botswana Brunei Darussalam Channel Islands China Hong Kong S A R Cyprus Dominica Gambia Ghana Grenada Iraq Ireland Jord...

Страница 111: ...Power cord part number Used in these countries and regions 39M5199 Japan 39M5068 Argentina Paraguay Uruguay 39M5226 India 39M5240 Brazil Chapter 4 Parts listing Lenovo Converged HX Series Type 8695 99 ...

Страница 112: ...100 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 113: ...rmation about getting service and assistance see Appendix D Getting help and technical assistance on page 1207 Removing and replacing guidelines Use the guidelines to remove and replace components in the Lenovo Converged HX Series Type 8695 Attention Static electricity that is released to internal server components when the server is powered on might cause the system to halt which might result in ...

Страница 114: ...or hot plug USB devices However you must turn off the server before you perform any steps that involve removing or installing adapter cables and you must disconnect the power source from the server before you perform any steps that involve removing or installing a riser card Blue on a component indicates touch points where you can grip the component to remove it from or install it in the server op...

Страница 115: ...eplace hot swap components Follow these guidelines when you work inside a server that is turned on Avoid wearing loose fitting clothing on your forearms Button long sleeved shirts before working inside the server do not wear cuff links while you are working inside the server Do not allow your necktie or scarf to hang inside the server Remove jewelry such as bracelets necklaces rings and loose fitt...

Страница 116: ... instructions in this section for changing any of the major hardware components Except for hot swap components such as drives fans and power supplies it is necessary to remove the appliance from the cluster and cleanly shutdown the hypervisor before changing the hardware After replacing the hardware component the server and hypervisor can be restarted For hardware it might be necessary to update t...

Страница 117: ...enovo Converged HX Series appliances contain two power supplies Identify the failed power supply by checking in Prism XClarity Administrator or the indicator lights on the power supply units 2 Disconnect the power cable for the power supply to be replaced being careful not to dislodge the other power cable 3 Remove the power supply as described in Removing a hot swap ac power supply on page 179 4 ...

Страница 118: ...No error shown in Lenovo XClarity Administrator No error shown in Prism Replacing a network interface card NIC The Lenovo Converged HX Series appliances can support up to eight network ports two or four 10 GbE ports up to 2 NICs and four 1 GbE ports on the motherboard A node requires network connectivity to function as part of a cluster If one network interface is available the failure of the othe...

Страница 119: ...C as described in Replacing an adapter in a riser card assembly on page 152 6 Replace the top cover as described in Replacing the top cover on page 118 7 Push the node chassis back into the rack and reconnect the cables as necessary Power on the node 8 Start the node by following the hypervisor specific Node Start procedure described in the Nutanix Hardware Replacement Documentation 9 Verify that ...

Страница 120: ...adapter is installed on the system motherboard It is replaced using the Replacing the dedicated slotless HBA controller on page 148 procedure The Lenovo Converged HX7510 contains an additional two HBA adapters with one installed in a riser and the other installed vertically in the motherboard Use one of these two procedures to replace the HBA adapter Replacing an adapter in a riser card assembly o...

Страница 121: ...the IMM web console to browse the post event log The event log will contain information about the location of the DIMM fault 2 Shut down the node by following the hypervisor specific Node Shutdown procedure described in the Nutanix Hardware Replacement Documentation 3 Power off the node and disconnect all the cables if the cable management arm is not in place Pull the node chassis out of the rack ...

Страница 122: ...s a level 2 CRU and should be performed by a trained Lenovo field representative To replace the system board perform the following steps 1 Shut down the node by following the hypervisor specific Node Shutdown procedure described in the Nutanix Hardware Replacement Documentation 2 Power off the node disconnect all cables to the node and remove the node from the rack as necessary 3 Remove the top co...

Страница 123: ...the main IMM menu screen to configure the boot SSD for the Lenovo Converged HX Series appliances Configure boot drive virtual drives Select virtual drive for booting 9 Use the Phoenix installer to reinstall the hypervisor and CVM by following the Imaging a Node procedure in the appendix of the Nutanix Field Installation Guide Internal cable routing and connectors This section provides information ...

Страница 124: ...routed lower than the DIMM latches 8x2 5 inch drive model HX3510 G The internal routing for the 8x2 5 inch drive model cables The following illustration shows the internal routing for the 8x2 5 inch drive model cables Note There might be 3 or 4 power connectors on the system board depending on your configuration However this difference will not affect the cable routing Follow the following illustr...

Страница 125: ...AS signal cable SAS 0 SAS 1 Figure 38 Cable connection SAS signal cable Power configuration cable SAS 0 SAS 1 Figure 39 8x2 5 inch hot swap hard disk drive cabling 24x2 5 inch drive model HX7510 The internal routing for the 24x2 5 inch drive model cables Chapter 5 Removing and replacing components 113 ...

Страница 126: ...ble routing 24x2 5 inch hot swap hard disk drive model 24x2 5 inch hot swap hard disk drive with 3 identical backplanes 2 5 inch HDD hot swap backplane Power configuration cable SAS signal cable SAS 0 SAS 1 2 5 inch HDD hot swap backplane Power configuration cable SAS signal cable SAS 0 SAS 1 2 5 inch HDD hot swap backplane Power configuration cable SAS signal cable SAS 0 SAS 1 Figure 40 24x2 5 in...

Страница 127: ...are routed lower than the DIMM latches 8x3 5 inch drive model HX5510 and HX5510 C The internal routing for the 8x3 5 inch drive model cables The following illustration shows the internal routing for the 8x3 5 inch drive model cables Note There might be 3 or 4 power connectors on the system board depending on your configuration However this difference will not affect the cable routing Follow the fo...

Страница 128: ... might differ slightly from your hardware Removing the top cover Use this information to remove the top cover To remove the top cover complete the following steps Step 1 Read the safety information that begins on page Safety on page v and Removing and replacing guidelines on page 101 Step 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessa...

Страница 129: ...000000 00000000000000 00000000000000 00000000000000 00000000000000 00000000000000 Figure 43 Unscrewing the cover lock Step 5 1 Push the tab on the cover release latch 2 then fully open the cover release latch Slide the top cover to the rear 3 then lift the top cover off the server Set the top cover aside Attention For proper cooling and airflow replace the server cover before you turn on the serve...

Страница 130: ...f the top cover engage the chassis correctly Step 2 Place the cover release latch in the open up position Step 3 Position the top cover on top of the server Step 4 Insert the bottom tabs of the top cover into the matching slots in the server chassis Step 5 Pivot the cover release latch as shown and slide the top cover to the front at the same time until the top cover snaps into position 00 00 00 0...

Страница 131: ...Step 7 Slide the server into the rack Step 8 Reconnect the external cables and power cords Removing and replacing Tier 1 CRUs Replacement of Tier 1 CRUs is your responsibility If Lenovo installs a Tier 1 CRU at your request you will be charged for the installation The illustrations in this document might differ slightly from your hardware Removing the air baffle When you work with some optional de...

Страница 132: ...oling and airflow replace the air baffle before you turn on the server Operating the server with the air baffle removed might damage server components Step 6 If you are instructed to return the air baffle follow all of the packaging instructions and use any packaging materials for shipping that are supplied to you Replacing the air baffle Use this information to replace the air baffle To replace t...

Страница 133: ...y cables that you removed Step 9 Turn on the peripheral devices and the server Removing the power paddle module Use this information to remove the power paddle module To remove the power paddle module complete the following steps Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 Turn off the server and disconnect all power c...

Страница 134: ...dule To install the power paddle module complete the following steps Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessary Step 3 Remove the top cover see Removing the top cover on page 116 Step 4 Grasp the handle and a...

Страница 135: ...y Use this information to remove the front USB assembly Note The front USB assembly is available only on some models To remove the front USB assembly complete the following steps Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables...

Страница 136: ...ly complete the following steps Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessary Step 3 Remove the top cover see Removing the top cover on page 116 Step 4 Align and slide the front USB assembly into the server unti...

Страница 137: ...into the rack Step 8 Reconnect the power cords and any cables that you removed Step 9 Turn on the peripheral devices and the server Removing a hot swap hard disk drive Use this information to remove a hot swap hard disk drive Attention To avoid damage to the hard disk drive connectors make sure that the server top cover is in place and fully closed whenever you install or remove a hard disk drive ...

Страница 138: ...k drive Figure 54 2 5 inch hot swap hard disk drives removal 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 000 000 Latch Handle 3 5 inch hot swap hard disk drive Figure 55 3 5 inch hot swap hard...

Страница 139: ...s and PCI Express slots covered or occupied When you install a drive or a PCI Express adapter save the EMC shield and filler panel from the bay or PCI Express adapter slot cover in the event that you later remove the device To install a hot swap SAS or SATA hard disk drive complete the following steps Note If you have only one hard disk drive you must install it in the bay 0 upper left Step 1 Read...

Страница 140: ...isk drive activity LED is flashing the drive is being accessed Step 5 If you are installing additional hot swap hard disk drives do so now Step 6 Turn on the peripheral devices and the server Removing a memory module Use this information to remove a memory module To remove a dual inline memory module DIMM complete the following steps Step 1 Read the safety information that begins on Safety on page...

Страница 141: ...ry standard double data rate 4 DDR4 2400 MHz PC4 19200 registered or load deduction synchronous dynamic random access memory SDRAM dual inline memory modules DIMMs with error correcting code ECC See http www lenovo com serverproven for a list of supported memory modules for the server The specifications of a DDR4 DIMM are on a label on the DIMM in the following format gggggeRxff PC4v wwwwwm aa bb ...

Страница 142: ...MMs per channel the memory runs at 1866 MHz All channels in a server run at the fastest common frequency Do not install registered and load reduction DIMMs in the same server The maximum memory speed is determined by the combination of the microprocessor DIMM speed DIMM type Operating Modes in UEFI settings and the number of DIMMs installed in each channel The server supports a maximum of 24 singl...

Страница 143: ...ed when microprocessor 2 is installed The following illustration shows the location of the DIMM connectors on the system board DIMM 3 DIMM 9 DIMM 6 DIMM 12 DIMM 2 DIMM 8 DIMM 5 DIMM 11 DIMM 1 DIMM 7 DIMM 4 DIMM 10 Microprocessor 1 CPU1 DIMM 15 DIMM 21 DIMM 18 DIMM 24 DIMM 14 DIMM 20 DIMM 17 DIMM 23 DIMM 13 DIMM 19 DIMM 16 DIMM 22 Microprocessor 2 CPU2 Figure 59 DIMM connectors location DIMM instal...

Страница 144: ...usly If a failure occurs the memory controller switches from the primary pair of memory DIMMs to the backup pair of DIMMs To enable memory mirrored channel through the Setup Utility select System Settings Memory For more information see Using the Setup Utility on page 35 When you use the memory mirrored channel feature consider the following information When you use memory mirrored channel you mus...

Страница 145: ...y on page 35 When you use the memory rank sparing feature consider the following information The memory rank sparing feature is supported on server models with an Intel Xeon E5 2600 v4 series microprocessor The maximum available memory is reduced when memory rank sparing mode is enabled The following diagram lists the DIMM connectors on each memory channel DIMM 3 DIMM 9 DIMM 6 DIMM 12 DIMM 2 DIMM ...

Страница 146: ...9 22 Replacing a memory module Use this information to replace a memory module Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessary Step 3 Remove the top cover see Removing the top cover on page 116 Step 4 Remove the a...

Страница 147: ... the DIMM and the retaining clips the DIMM has not been correctly inserted open the retaining clips remove the DIMM and then reinsert it Step 10 Reconnect the power cords and any cables that you removed Step 11 Replace the air baffle see Replacing the air baffle on page 120 Note Close all the retaining clips even for slots without DIMMs installed before replacing the air baffle Step 12 Replace the...

Страница 148: ...ted to return the fan cage assembly follow all of the packaging instructions and use any packaging materials for shipping that are supplied to you Replacing the fan cage assembly Use this information to replace the fan cage assembly To install the fan cage assembly complete the following steps Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines ...

Страница 149: ...n Attention To ensure proper server operation replace a failed hot swap fan within 30 seconds To remove a hot swap fan complete the following steps Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 Remove the top cover see Removing the top cover on page 116 The LED on the system board near the connector for the failing singl...

Страница 150: ...Attention To ensure proper operation replace a failed hot swap fan within 30 seconds To replace a hot swap fan complete the following steps Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 Remove the top cover see Removing the top cover on page 116 Step 3 Touch the static protective package that contains the new fan to any ...

Страница 151: ...o called lightpath LCD operation panel assembly To remove the media cage complete the following steps Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessary Step 3 Remove the top cover see Removing the top cover on page ...

Страница 152: ...ure 67 Cable routing Step 5 Loosen the thumbscrew that is used to secure the media cage onto the server Thumbscrew Figure 68 Thumbscrew Step 6 Carefully push the media cage out of the server and set it aside 140 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 153: ...lled lightpath LCD operation panel assembly Use this information to replace the media cage also called lightpath LCD operation panel assembly To install the media cage complete the following steps Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 Turn off the server and peripheral devices and disconnect all power cords Step ...

Страница 154: ... Tighten the thumbscrew to secure the media cage onto the server Thumbscrew Figure 71 Thumbscrew Step 6 Reconnect the USB and operator information LCD panel cables to the system board first then route the cables as the following illustration Remember to insert the cables into the cable clip for proper routing 142 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 155: ...this information to remove a riser card assembly See http www lenovo com serverproven for a list of riser card assemblies that you can use with the server To remove a riser card assembly complete the following steps Step 1 Read the safety information that begins on page Safety on page v and Removing and replacing guidelines on page 101 Step 2 Turn off the server and peripheral devices and disconne...

Страница 156: ...ength and low profile adapters for HX7510 only 0 0 0 0 0 0 0 0 0 000 000 000 000 000 000 000 000 0 0 0 0 0 0 0 0 00 00 00 00 00 00 00 00 00 00 00000 00000 00000 00000 PCI riser card assembly 2 PCI riser card assembly 1 Figure 73 Riser card assembly removal half length and low profile adapters For full height full length adapters for HX3510 G only 144 HX3510 G HX5510 HX5510 C HX7510 Installation an...

Страница 157: ... the system board The following information indicates the riser card slots PCI riser slot 1 the farthest slot from the power supplies You must install a riser card assembly in slot 1 with microprocessor 1 PCI riser slot 2 the closest slot to the power supplies You must install a riser card assembly in slot 2 with microprocessor 2 PCI riser card brackets must be installed even if you do not install...

Страница 158: ...embly is seated correctly in the connector on the system board For half length and low profile adapters for HX7510 only 0 0 0 0 0 0 0 0 0 000 000 000 000 000 000 000 000 0 0 0 0 0 0 0 0 00 00 00 00 00 00 00 00 00 00 00000 00000 00000 00000 PCI riser card assembly2 PCI riser card assembly1 Figure 75 Riser card assembly installation half length and low profile adapters For full height full length ad...

Страница 159: ...A controller can be installed in the dedicated connector on the system board see System board internal connectors on page 23 for the location of the connectors To remove the dedicated slotless HBA controller complete the following steps Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 Turn off the server and peripheral devi...

Страница 160: ...ep 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessary Step 3 Remove the top cover see Removing the top cover on page 116 Step 4 If you are installing a new or replacement controller touch the static protective package tha...

Страница 161: ...an adapter Removing an adapter in a riser card assembly Use this information to remove an adapter This topic describes removing an adapter from a expansion slot in a riser card assembly These instructions apply to PCI adapters such as video graphic adapters and network adapters The following illustration shows the locations of the adapter expansion slots from the rear of the server 000000 000000 0...

Страница 162: ...power cords then remove the top cover see Removing the top cover on page 116 Step 3 Press down on the left and right side latches and slide the server out of the rack enclosure until both slide rails lock then remove the top cover see Removing the top cover on page 116 Step 4 Remove the riser card assembly that contains the adapter see Removing a riser card assembly on page 143 If you are removing...

Страница 163: ...on slot 4 or slot 5 To remove an adapter in PCI expansion slot 4 or slot 5 complete the following steps Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 Turn off the server and peripheral devices and disconnect all power cords then remove the top cover see Removing the top cover on page 116 Step 3 Press down on the left and...

Страница 164: ...llowing adapters support 10 Gbps transfer rate only Intel X710 2x10GbE SFP Adapter Intel X710 ML2 4x10GbE SFP Adapter Intel X710 DA2 ML2 2x10GbE SFP Adapter Replacing an adapter in a riser card assembly Use this section to replace an adapter in a riser card assembly The following illustration shows the locations of the adapter expansion slots from the rear of the server 000000 000000 000000 000000...

Страница 165: ...figurations Description Supported maximum total memory size NVIDIA Tesla K8 K40c and M60 Active 1 TB Do not install the following adapters in the slot 3 and the slot 8 Table 18 Non supported adapters in the slot 3 and the slot 8 Adapter description Option part number FRU part number N2215 SAS SATA HBA for System x 47C8675 47C8676 N2215 SAS SATA HBA for System x 00AE912 00AE914 Intel x520 Dual Port...

Страница 166: ... adapter firmly into the PCI connector on the riser card 1 3 2 Adapter Adapter connector Expansion slot cover Bracket PCI riser card assembly Figure 84 Adapter installation Step 8 Rotate the retention latch to the close position Note Fasten the screw on the retention latch to secure the adapter Step 9 If you are installing a full height full length adapter insert the shipping brackets 00000 00000 ...

Страница 167: ... seated correctly in the connector on the system board For half length and low profile adapters for HX7510 only 0 0 0 0 0 0 0 0 0 000 000 000 000 000 000 000 000 0 0 0 0 0 0 0 0 00 00 00 00 00 00 00 00 00 00 00000 00000 00000 00000 PCI riser card assembly2 PCI riser card assembly1 Figure 86 Riser card assembly installation half length and low profile adapters For full height full length adapters f...

Страница 168: ...Replacing an adapter in PCI expansion slot 4 or slot 5 Use this section to replace an adapter in PCI expansion slot 4 or slot 5 To replace an adapter complete the following steps Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables...

Страница 169: ... 9 Perform any configuration tasks that are required for the adapter Step 10 Reinstall the top cover see Replacing the top cover on page 118 Step 11 Slide the server into the rack Step 12 Reconnect the power cords and any cables that you removed Step 13 Turn on the peripheral devices and the server Removing an EIA assembly Use the following instructions to remove an EIA assembly for 2 5 inch and 3...

Страница 170: ...locks on cable connectors when you disconnect all cables from the system board Failing to release them before removing the cables will damage the cable sockets on the system board The cable sockets on the system board are fragile Any damage to the cable sockets may require replacing the system board Front USB operator information panel cable Figure 89 Front USB operator information panel cable rem...

Страница 171: ...mbly and pull it slightly forward to remove it from the server EIA assembly Figure 92 EIA assembly removal 9 Position the EIA assembly as shown in the following illustration then remove the assembly out of the server Chapter 5 Removing and replacing components 159 ...

Страница 172: ...l external cables 3 Remove the cover see Removing the top cover on page 116 4 Remove the fan cage assembly see Removing the fan cage assembly on page 135 5 Disconnect the front video cable from the system board Note Disengage all latches release tabs or locks on cable connectors when you disconnect all cables from the system board Failing to release them before removing the cables will damage the ...

Страница 173: ...deo cable Figure 94 Front video cable removal 6 Loosen screws and remove them Screws Figure 95 Screw removal 7 Tilt the cable cover and remove it from the server Chapter 5 Removing and replacing components 161 ...

Страница 174: ...aterials for shipping that are supplied to you 3 5 inch model There are the right EIA assembly and the left EIA assembly on the server use the following steps to remove them For the right EIA assembly 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 2 Turn off the server and peripheral devices and disconnect the power cord and all exte...

Страница 175: ...before removing the cables will damage the cable sockets on the system board The cable sockets on the system board are fragile Any damage to the cable sockets may require replacing the system board Front USB operator information panel cable Figure 98 Front USB operator information panel cable removal 6 Loosen screws and remove them Screws Figure 99 Screw removal 7 To remove the cable cover angle t...

Страница 176: ... pull it slightly forward to remove it from the server EIA assembly Figure 101 EIA assembly removal 9 Position the EIA assembly as shown in the following illustration then remove the assembly out of the server 164 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 177: ...d all external cables 3 Remove the top cover see Removing the top cover on page 116 4 Remove the fan cage assembly see Removing the fan cage assembly on page 135 5 Disconnect the front video cable form the system board Note Disengage all latches release tabs or locks on cable connectors when you disconnect all cables from the system board Failing to release them before removing the cables will dam...

Страница 178: ...Figure 103 Front video cable removal 6 Loosen screws and remove them Screws Figure 104 Screw removal 7 Tilt the cable cover and remove it from the server 166 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 179: ...ng instructions and use any packaging materials for shipping that are supplied to you Replacing an EIA assembly Use the following instructions to replace an EIA assembly for 2 5 inch and 3 5 inch models Note The EIA assembly is available only on some models 2 5 inch model There are the right EIA assembly and the left EIA assembly on the server use the following steps to replace them Chapter 5 Remo...

Страница 180: ...cord and all external cables 3 Remove the top cover see Removing the top cover on page 116 4 Remove the fan cage see Removing the fan cage assembly on page 135 5 Insert the cable connector into the cable connector holder EIA assembly Cable connector holder Figure 107 Cable connector installation 6 Align the EIA assembly with the alignment pin 168 HX3510 G HX5510 HX5510 C HX7510 Installation and Se...

Страница 181: ...mbly alignment 7 Push the EIA assembly slightly toward the rear of the server to fix the EIA assembly on the server EIA assembly Figure 109 EIA assembly installation 8 Tilt and install the cable cover Chapter 5 Removing and replacing components 169 ...

Страница 182: ...9 Fasten screws Screws Figure 111 Screw installation 10 Connect the front USB operator information panel cables to the system board and the connector mounted on the chassis side wall 170 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 183: ...peripheral devices and the server For the left EIA assembly 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 2 Turn off the server and peripheral devices and disconnect the power cord and all external cables 3 Remove the top cover see Removing the top cover on page 116 4 Remove the fan cage assembly see Removing the fan cage assembly o...

Страница 184: ... rear of the server fix the EIA assembly on the server Alignment pin EIA assembly Figure 114 EIA assembly alignment 7 Tilt and install the cable cover Cable cover Figure 115 Cable cover installation 8 Fasten screws 172 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 185: ...mbly on page 136 11 Replace the top cover see Replacing the top cover on page 118 12 Slide the server into the rack 13 Reconnect the power cords and any cables that you removed 14 Turn on the peripheral devices and the server 3 5 inch model There are the right EIA assembly and the left EIA assembly on the server use the following steps to replace them Chapter 5 Removing and replacing components 17...

Страница 186: ...r cord and all external cables 3 Remove the cover see Removing the top cover on page 116 4 Remove the fan cage see Removing the fan cage assembly on page 135 5 Insert the cable connector into the cable connector holder EIA assembly Cable connector holder Figure 118 Cable connector installation 6 Align the EIA assembly with the alignment pin 174 HX3510 G HX5510 HX5510 C HX7510 Installation and Serv...

Страница 187: ...ghtly toward the rear of the server to fix the EIA assembly on the server EIA assembly Figure 120 EIA assembly installation 8 Angle the cable cover as shown in the following illustration and slide the cable arm towards the front of the server Chapter 5 Removing and replacing components 175 ...

Страница 188: ...n 9 Fasten screws Screws Figure 122 Screw installation 10 Connect the front USB operator information panel cables to the system board and the connector mounted on the chassis side wall 176 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 189: ...peripheral devices and the server For the left EIA assembly 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 2 Turn off the server and peripheral devices and disconnect the power cord and all external cables 3 Remove the top cover see Removing the top cover on page 116 4 Remove the fan cage assembly see Removing the fan cage assembly o...

Страница 190: ...ear of the server to fix the EIA assembly on the server Alignment pin EIA assembly Figure 125 EIA assembly alignment 7 Tilt and install the cable cover Cable cover Figure 126 Cable cover installation 8 Fasten screws 178 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 191: ...e the top cover see Replacing the top cover on page 118 12 Slide the server into the rack 13 Reconnect the power cords and any cables that you removed 14 Turn on the peripheral devices and the server Removing a hot swap ac power supply Use this information to remove a hot swap ac power supply When you remove or install a hot swap power supply observe the following precautions Chapter 5 Removing an...

Страница 192: ...e no serviceable parts inside these components If you suspect a problem with one of these parts contact a service technician To remove a hot swap ac power supply complete the following steps Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 If only one power supply is installed turn off the server and peripheral devices and ...

Страница 193: ... For more information and to download the utility go to http www ibm com systems bladecenter resources powerconfig html The server comes with one hot swap 12 volt output power supply that connects to power supply bay 1 The input voltage is 100 127 V ac or 200 240 V ac auto sensing for AC power supplied and is 48V dc or 60V dc auto sensing for DC power supplies Power supplies in the server must be ...

Страница 194: ...el attached There are no serviceable parts inside these components If you suspect a problem with one of these parts contact a service technician To install a power supply complete the following steps Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 Touch the static protective package that contains the hot swap power supply ...

Страница 195: ...ower cord connector on the power supply The following illustration shows the power cord connectors on the back of the server 000000 000000 000000 000000 00 00 00 00 00 00 0 0 0 0 0 0 0 0 00 00 00 00 00 0000000 0000000 0000000 Power cord connectors 000000 000000 000000 Step 6 Route the power cord through the cable hook and loop on the rear of the server to prevent the power cord from being accident...

Страница 196: ... Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessary Step 3 Remove the top cover see Removing the top cover on page 116 Step 4 Pull the hard disk drives or fillers out of the server slightly to disengage them from the...

Страница 197: ...5 inch hot swap hard disk drive backplane To install the 2 5 inch hot swap hard disk drive backplane complete the following steps Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 Turn off the server and disconnect all power cords and external cables Step 3 Remove the top cover see Removing the top cover on page 116 Step 4 P...

Страница 198: ...e Use this information to remove the 3 5 inch hot swap hard disk drive backplane To remove the 3 5 inch hot swap hard disk drive backplane complete the following steps Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 Turn off the server and peripheral devices and disconnect all power cords Step 3 Remove the top cover see Re...

Страница 199: ...00000 00000000000000000 00000000000000000 00000000000000000 00000000000000000 00000000000000000 00000000000000000 00000000000000000 00000000000000000 00000000000000000 00000000000000000 00000000000000000 00000000000000000 00000000000000000 00000000000000000 2 4 3 1 Plunger Figure 134 3 5 inch hot swap hard disk drive backplane removal For twelve 3 5 inch hot swap hard disk drive backplane 2 3 4 1 ...

Страница 200: ...an cage assembly on page 135 Step 6 1 Insert the backplane tabs into slots on the bottom of the drive cage at an angle then 2 rotate the backplane toward the front the server Note You can connect the cables to the drive backplane before installing the backplane onto the cage or you can connect the cables after you install the backplane if that is easier for you Step 7 3 Push the b backplane to the...

Страница 201: ...vo has designed this product with your safety in mind The lithium battery must be handled correctly to avoid possible danger If you replace the battery you must adhere to the following instructions Note In the U S call 1 800 IBM 4333 for information about battery disposal If you replace the original lithium battery with a heavy metal battery or a battery with heavy metal components be aware of the...

Страница 202: ...ose of the battery as required by local ordinances or regulations To remove the coin cell battery complete the following steps Step 1 Read the safety information that begins on Safety on page v and Removing and replacing guidelines on page 101 Step 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessary Step 3 Remove the top cover see Removi...

Страница 203: ...orce Figure 139 Coin cell battery removal c Use your thumb and index finger to lift the battery from the socket Attention Do not lift the battery by using excessive force Failing to remove the battery properly may damage the socket on the system board Any damage to the socket may require replacing the system board Step 6 Dispose of the battery as required by local ordinances or regulations See the...

Страница 204: ...module containing a lithium battery replace it only with the same module type made by the same manufacturer The battery contains lithium and can explode if not properly used handled or disposed of Do not Throw or immerse into water Heat to more than 100 C 212 F Repair or disassemble Dispose of the battery as required by local ordinances or regulations To install the replacement coin cell battery c...

Страница 205: ...ver from the battery holder use your fingers to install the battery cover on top of the battery connector Step 7 Reinstall the riser card assembly 2 see Replacing a riser card assembly on page 145 if necessary Step 8 Install the top cover see Replacing the top cover on page 118 Step 9 Slide the server into the rack Step 10 Reconnect the external cables then reconnect the power cords and turn on th...

Страница 206: ...ry 3 Remove the top cover see Removing the top cover on page 116 4 Remove the fan cage assembly See Removing the fan cage assembly on page 135 5 Pull up the release latch slightly and slide the LCD panel assembly out of the server 00000000000000000 00000000000000000 00000000000000000 00000000000000000 00000000000000000 00000000000000000 00000000000000000 00000000000000000 00000000000000000 0000000...

Страница 207: ...at begins on Safety on page v and Removing and replacing guidelines on page 101 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessary 3 Remove the top cover see Removing the top cover on page 116 4 Remove the fan cage assembly Removing the fan cage assembly on page 135 5 Remove the media cage see Removing the media cage also called lightpa...

Страница 208: ...any packaging materials for shipping that are supplied to you Replacing the LCD system information display panel Use this information to replace the LCD system information display panel Note The LCD system information display panel is available on some models Replacing the LCD panel assembly on a 3 5 inch model To install the LCD panel assembly on a 3 5 inch model complete the following steps 1 Re...

Страница 209: ...ver Retention bracket 2 1 Figure 147 Retention bracket removal 6 Carefully insert the LCD system information display panel into place LCD system information display panel Figure 148 LCD system information display panel installation 7 Hinge the retention bracket into the slot on the LCD panel assembly and rotate it until it clicks into place Retention bracket Figure 149 Retention bracket installati...

Страница 210: ...onnector Operator information LCD panel connector Operator information LCD panel cable Figure 151 LCD panel assembly cable routing Note To connect the LCD panel assembly cable on the system board press evenly on the cable Pressing on one side of the cable might cause damage to the cable or connector 11 Replace the top cover see Replacing the top cover on page 118 198 HX3510 G HX5510 HX5510 C HX751...

Страница 211: ...l external cables if necessary 3 Remove the top cover see Removing the top cover on page 116 4 Remove the fan cage assembly Removing the fan cage assembly on page 135 5 Remove the media cage see Removing the media cage also called lightpath LCD operation panel assembly on page 139 6 A separate bezel is needed if your media cage has a bezel without the opening and buttons for the LCD panel To remov...

Страница 212: ... to the left to disengage the retention bracket 2 Rotate the retention bracket to remove it from the server Media cage Retention bracket 2 1 Figure 154 Retention bracket removal 8 Carefully insert the LCD system information display panel into place 200 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 213: ...to place Media cage Retention bracket Figure 156 Retention bracket installation 10 If you have removed the media cage bezel install the new media cage bezel with LCD opening and buttons Angle the media cage bezel and insert the three hooks on the rear side of the media cage bezel into slots on the media cage The following illustration shows the location of three hooks Chapter 5 Removing and replac...

Страница 214: ...g the top cover on page 118 14 Slide the server into the rack 15 Reconnect the power cords and any cables that you removed 16 Turn on the peripheral devices and the server Removing the operator information panel assembly Use this information to remove the operator information panel assembly To remove the operator information panel complete the following steps Step 1 Read the safety information tha...

Страница 215: ...removal Step 6 If you are instructed to return the operator information panel assembly follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing the operator information panel assembly Use this information to replace the operator information panel assembly To install the operator information panel complete the following steps Step 1 Read the ...

Страница 216: ...n panel 0000000000000000000 Operator information LCD panel connector Operator information LCD panel cable Operator information panel assembly Figure 161 Operator information panel cable routing Note To connect the operator information panel cable on the system board press evenly on the cable Pressing on one side of the cable might cause damage to the cable or connector Step 6 Replace the top cover...

Страница 217: ...ted to the SATADOM Step 5 Pivot the SATADOM bracket latch and then remove the SATADOM from the bracket 00 00 00 00 00 00 00 00 0000 0000 0000 0000 0000 0000 0 0 0 0 0 0 00 00 00 00 00 00 00 00 000000 000000 000000 000000 000000 0000000000000000000000 0000000000000000000000 0000000000000000000000 0000000000000000000000 0000000000000000000000 0000000000000000000000 0000000000000000000000 00000000000...

Страница 218: ...000 000000 000000 000000 000000 Figure 163 SATADOM bracket installation Step 6 Insert the SATADOM into the bracket and press the SATADOM as shown until it is secured by the bracket 0000000000000000000000 0000000000000000000000 0000000000000000000000 0000000000000000000000 0000000000000000000000 0000000000000000000000 0000000000000000000000 0000000000000000000000 0000000000000000000000 000000000000...

Страница 219: ...oving a microprocessor and heat sink Use this information to remove a microprocessor and heat sink Attention Microprocessors are to be removed only by trained technicians Important Always use the microprocessor installation tool to remove a microprocessor Failing to use the microprocessor installation tool may damage the microprocessor sockets on the system board Any damage to the microprocessor s...

Страница 220: ...e top cover see Removing the top cover on page 116 Step 4 Remove the air baffle see Removing the air baffle on page 119 Step 5 Locate the microprocessor to be removed see System board internal connectors on page 23 Step 6 If you are removing microprocessor 1 remove the memory modules from DIMM connectors 6 and 7 If you are removing microprocessor 2 remove the memory modules from DIMM connectors 18...

Страница 221: ...nk out of the server After removal place the heat sink with the thermal grease side up on a clean flat surface Heat sink release lever Lock tab Heat sink Figure 168 Heat sink removal Step 8 Open the microprocessor socket release levers and retainer Chapter 5 Removing and replacing components 209 ...

Страница 222: ...the socket Step 9 Remove the microprocessor from the socket a Select the empty installation tool and ensure that the handle is in the unlocked position If the installation tool handle is not in the unlocked position use the following instructions for your installation tool 1 lift the interlock latch and hold it up while you 2 twist the microprocessor installation tool handle counterclockwise to th...

Страница 223: ... x6xx v3 E5 x6xx v4 E5 x6xx v3 E5 x6xx v4 Lock Position Unlock Position Figure 171 Locked and unlocked positions b Align the installation tool with the screws as shown in the following graphic and lower the installation tool on the microprocessor The installation tool rests flush on the socket only when it is aligned correctly Chapter 5 Removing and replacing components 211 ...

Страница 224: ...ion tool clockwise until it locks in the H or L position depending on the size of microprocessor and then lift the microprocessor out of the socket Handle Installation tool Microprocessor Figure 173 Installation tool handle adjustment d Lift the microprocessor out of the socket 212 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 225: ... the microprocessor sockets on the system board Any damage to the microprocessor sockets may require replacing the system board The server supports up to two Intel Xeon E5 2600 v4 series multi core microprocessors which are designed for the LGA 2011 socket See http www lenovo com serverproven for a list of supported microprocessors Do not mix microprocessors with different cores in the same server...

Страница 226: ...d requires replacing the thermal grease To order an additional optional microprocessor contact your sales representative or reseller Installation tool has two settings for installing two different sizes of microprocessors The settings that are marked on the tool are L for smaller low core microprocessors and H for larger high core microprocessors H Installation tool Microprocessor Figure 175 Micro...

Страница 227: ... as the first release lever to open and open it b Open the second release lever on the microprocessor socket c Open the microprocessor retainer Attention Do not touch the connectors on the microprocessor and the microprocessor socket Step 8 Install the microprocessor on the microprocessor socket a Touch the static protective package that contains the new microprocessor to any unpainted on the chas...

Страница 228: ...tion tool Microprocessor Alignment pins Figure 178 Installation tool alignment c Install the microprocessor using the following instructions for your installation tool Twist the handle of the installation tool assembly counterclockwise to the unlocked position until you can not twist the handle any further then lift the installation tool out of the socket Figure 179 Installation tool handle adjust...

Страница 229: ...e socket Make sure that the microprocessor is oriented and aligned correctly in the socket before you try to close the microprocessor retainer Do not touch the thermal material on the bottom of the heat sink or on top of the microprocessor Touching the thermal material will contaminate it Step 9 Remove the cover from the retainer bracket if one is present Store the cover in a safe place Chapter 5 ...

Страница 230: ...t release levers and retainer 1 3 2 Microprocessor release lever Microprocessor release lever Figure 183 Microprocessor socket levers and retainer engagement a Close the microprocessor retainer on the microprocessor socket b Identify which release lever is labeled as the first release lever to close and close it c Close the second release lever on the microprocessor socket Step 11 Install the heat...

Страница 231: ...n page 221 for more information Heat sink Thermal grease Flange Figure 184 Thermal grease a Remove the plastic protective cover from the bottom of the heat sink b Grasp the heat sink firmly as the following illustration to avoid possible damage to the heat sink Figure 185 Heat sink c Position the heat sink over the microprocessor The heat sink is keyed to assist with proper alignment Chapter 5 Rem...

Страница 232: ...thermal material side down f Press firmly on the heat sink g Rotate the heat sink retention module release lever to the closed position and hook it underneath the lock tab Heat sink release lever Heat sink Figure 187 Heat sink retention module release lever Step 12 Reinstall the air baffle see Replacing the air baffle on page 120 Step 13 Install the top cover see Replacing the top cover on page 11...

Страница 233: ...101 Read Handling static sensitive devices on page 103 To replace damaged or contaminated thermal grease on the microprocessor and heat sink complete the following steps Step 1 Place the heat sink on a clean work surface Step 2 Remove the cleaning pad from its package and unfold it completely Step 3 Use the cleaning pad to wipe the thermal grease from the bottom of the heat sink Note Make sure tha...

Страница 234: ...ir baffle on page 119 Step 5 Remove the heat sink see Removing a microprocessor and heat sink on page 207 Attention When you remove a microprocessor and heat sink be sure to keep each heat sink with its microprocessor for reinstallation Step 6 Use a screwdriver and remove the four screws that secure the retention module to the system board then lift the retention module from the system board Heat ...

Страница 235: ...he air baffle see Replacing the air baffle on page 120 Step 9 Install the top cover see Replacing the top cover on page 118 Step 10 Slide the server into the rack Step 11 Reconnect the power cords and any cables that you removed Step 12 Turn on the peripheral devices and the server Removing the system board Use this information to remove the system board Notes 1 When you replace the system board y...

Страница 236: ... of each DIMM as you remove it so that you can later reinstall it in the same connector Step 13 Trained technician only Remove all heat sinks and microprocessors and set them aside on a static protective surface for reinstallation see Removing a microprocessor and heat sink on page 207 Note Do not allow the thermal grease to come in contact with anything and keep each heat sink paired with its mic...

Страница 237: ... 00 00 0 0 0 0 000 000 000 000 000 000 0 0 0 00 00 00 00 00 00 00 00 00 00 00 00 00 00000 00000 00000 00000 1 2 Figure 193 System board removal Step 18 If you are instructed to return the system board follow all packaging instructions and use any packaging materials for shipping that are supplied to you Attention Make sure to place the socket covers for the microprocessor sockets on the system boa...

Страница 238: ...d Upgrade see Using the remote presence and blue screen capture features on page 41 Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code To install the system board complete the following steps Step 1 Read the safety ...

Страница 239: ...Step 10 Install the PCI riser card assemblies and adapters if any were installed see Replacing an adapter on page 152 and Replacing a riser card assembly on page 145 Step 11 Install the air baffle see Replacing the air baffle on page 120 Step 12 Install the fan cage assembly see Replacing the fan cage assembly on page 136 Step 13 Install the top cover see Replacing the top cover on page 118 Step 1...

Страница 240: ...S riser card see the user s guide that comes with the hypervisor memory key Hypervisor enables guest operating systems to function on the server For information about configuring the integrated Gigabit Ethernet controller see Configuring the Ethernet controller on page 43 How to send DSA data You can use the Enhanced Customer Data Repository to send diagnostic data to IBM Before you send diagnosti...

Страница 241: ...The event was recorded for audit purposes usually a user action or a change of states that is normal behavior Warning The event is not as severe as an error but if possible the condition should be corrected before it becomes an error It might also be a condition that requires additional monitoring or maintenance Error The event is a failure or critical condition that impairs service or an expected...

Страница 242: ...ction see the table for a list of events that automatically notify Support Table 19 Events that automatically notify Support Event ID Message String Automatically Notify Support 40000086 00000000 Test Call Home Generated by user arg1 Yes 40000087 00000000 Manual Call Home by user arg1 arg2 Yes 400000cb 00000000 The RAID controller has problem with the battery Please contact technical support to re...

Страница 243: ...tName DIMM 4 Yes 806f010c 2005ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 5 Yes 806f010c 2006ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 6 Yes 806f010c 2007ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 7 Yes 806f010c 2008ffff Uncorrec...

Страница 244: ...ectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 21 Yes 806f010c 2016ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 22 Yes 806f010c 2017ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 23 Yes 806f010c 2018ffff Uncorrectable error detected for PhysicalMemor...

Страница 245: ... Drive 14 Yes 806f010d 040fffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 15 Yes 806f010d 0410ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 16 Yes 806f010d 0411ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 17 Yes 806f010d 0412ffff The Drive StorageVolumeElementName has been ...

Страница 246: ...iled with FRB1 BIST condition All CPUs Yes 806f020d 0400ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 0 Yes 806f020d 0401ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 1 Yes 806f020d 0402ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 2 Yes 806...

Страница 247: ... Yes 806f020d 0415ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 21 Yes 806f020d 0416ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 22 Yes 806f020d 0417ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 23 Yes 806f020d 0418ffff Failure Predicted on...

Страница 248: ...s 806f050c 2008ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 8 Yes 806f050c 2009ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 9 Yes 806f050c 200affff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 10 Yes 806f050c 200bffff Memory Logging Limit R...

Страница 249: ...oryElementName on Subsystem MemoryElementName DIMM 23 Yes 806f050c 2018ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 24 Yes 806f050c 2581ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName All DIMMS Yes 806f060d 0400ffff Array ComputerSystemElementName has failed Drive 0 Yes 806f060d 0401ffff Array Com...

Страница 250: ...ComputerSystemElementName has failed Drive 19 Yes 806f060d 0414ffff Array ComputerSystemElementName has failed Drive 20 Yes 806f060d 0415ffff Array ComputerSystemElementName has failed Drive 21 Yes 806f060d 0416ffff Array ComputerSystemElementName has failed Drive 22 Yes 806f060d 0417ffff Array ComputerSystemElementName has failed Drive 23 Yes 806f060d 0418ffff Array ComputerSystemElementName has ...

Страница 251: ...0000001 00000000 Management Controller arg1 Network Initialization Complete This message is for the use case where a Management Controller network has completed initialization May also be shown as 4000000100000000 or 0x4000000100000000 Severity Info Serviceable No Automatically notify support No Alert Category System IMM Network event SNMP Trap ID 37 CIM Information Prefix IMM ID 0001 User Respons...

Страница 252: ...t Port data rate May also be shown as 4000000300000000 or 0x4000000300000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0003 User Response Information only no action is required 40000004 00000000 Ethernet Duplex setting modified from arg1 to arg2 by user arg3 This message is for the use case where A user modifies the ...

Страница 253: ...0000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0005 User Response Information only no action is required 40000006 00000000 Ethernet locally administered MAC address modified from arg1 to arg2 by user arg3 This message is for the use case where a user modifies the Ethernet Port MAC address setting May also be shown...

Страница 254: ...Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0007 User Response Information only no action is required 40000008 00000000 Hostname set to arg1 by user arg2 This message is for the use case where user modifies the Hostname of a Management Controller May also be shown as 4000000800000000 or 0x4000000800000000 Severity Info Serviceable N...

Страница 255: ...tically notify support No Alert Category System IMM Network event SNMP Trap ID 37 CIM Information Prefix IMM ID 0009 User Response Information only no action is required 4000000a 00000000 IP subnet mask of network interface modified from arg1 to arg2 by user arg3 This message is for the use case where a user modifies the IP subnet mask of a Management Controller May also be shown as 4000000a000000...

Страница 256: ...viceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0011 User Response Information only no action is required 4000000c 00000000 OS Watchdog response arg1 by arg2 This message is for the use case where an OS Watchdog has been enabled or disabled by a user May also be shown as 4000000c00000000 or 0x4000000c00000000 Severity Warning Serviceable N...

Страница 257: ...lete the following steps until the problem is solved 1 Make sure that the IMM network cable is connected 2 Make sure that there is a DHCP server on the network that can assign an IP address to the IMM 4000000e 00000000 Remote Login Successful Login ID arg1 from arg2 at IP address arg3 This message is for the use case where a user successfully logs in to a Management Controller May also be shown as...

Страница 258: ... Category none SNMP Trap ID CIM Information Prefix IMM ID 0015 User Response Information only no action is required 40000010 00000000 Security Userid arg1 had arg2 login failures from WEB client at IP address arg3 This message is for the use case where a user has failed to log in to a Management Controller from a web browser May also be shown as 4000001000000000 or 0x4000001000000000 Severity Warn...

Страница 259: ...o Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0017 User Response Complete the following steps until the problem is solved 1 Make sure that the correct login ID and password are being used 2 Have the system administrator reset the login ID or password 40000012 00000000 Remote access attempt failed Invalid userid or password received Userid is arg1 from WEB brows...

Страница 260: ...shown as 4000001300000000 or 0x4000001300000000 Severity Info Serviceable No Automatically notify support No Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0019 User Response Make sure that the correct login ID and password are being used 40000014 00000000 The arg1 on system arg2 cleared by user arg3 This message is for the use case where a Management Controller E...

Страница 261: ...le No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0021 User Response Information only no action is required 40000016 00000000 ENET arg1 DHCP HSTN arg2 DN arg3 IP arg4 SN arg5 GW arg6 DNS1 arg7 This message is for the use case where a Management Controller IP address and configuration has been assigned by the DHCP server May also be shown as 400000...

Страница 262: ...01700000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0023 User Response Information only no action is required 40000018 00000000 LAN Ethernet arg1 interface is no longer active This message is for the use case where a Management Controller ethernet interface is no longer active May also be shown as 4000001800000000 ...

Страница 263: ...y Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0025 User Response Information only no action is required 4000001a 00000000 DHCP setting changed to arg1 by user arg2 This message is for the use case where a user changes the DHCP setting May also be shown as 4000001a00000000 or 0x4000001a00000000 Severity Info Serviceable No Autom...

Страница 264: ...ble No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0027 User Response Information only no action is required 4000001c 00000000 Watchdog arg1 Screen Capture Occurred This message is for the use case where an operating system error has occurred and the screen was captured May also be shown as 4000001c00000000 or 0x4000001c00000000 Severity Info Serv...

Страница 265: ...D 22 CIM Information Prefix IMM ID 0029 User Response Complete the following steps until the problem is solved 1 Reconfigure the watchdog timer to a higher value 2 Make sure that the IMM Ethernet over USB interface is enabled 3 Reinstall the RNDIS or cdc_ether device driver for the operating system 4 Disable the watchdog Check the integrity of the installed operating system 5 Update the IMM firmwa...

Страница 266: ...he server This message is for the use case where a Management Controller firmware version does not match the server May also be shown as 4000001f00000000 or 0x4000001f00000000 Severity Error Serviceable No Automatically notify support No Alert Category System other SNMP Trap ID 22 CIM Information Prefix IMM ID 0031 User Response Update the IMM firmware to a version that the server supports Importa...

Страница 267: ...r arg1 clock has been set from NTP server arg2 This message is for the use case where a Management Controller clock has been set from the Network Time Protocol server May also be shown as 4000002100000000 or 0x4000002100000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0033 User Response Information only no action is ...

Страница 268: ...ing is correct 2 Try to import the certificate again 40000023 00000000 Flash of arg1 from arg2 succeeded for user arg3 This message is for the use case where a user has successfully flashed the firmware component MC Main Application MC Boot ROM BIOS Diagnostics System Power Backplane Remote Expansion Enclosure Power Backplane Integrated System Management Processor or Remote Expansion Enclosure Pro...

Страница 269: ...r SNMP Trap ID 22 CIM Information Prefix IMM ID 0036 User Response Information only no action is required 40000025 00000000 The arg1 on system arg2 is 75 full This message is for the use case where a Management Controller Event Log on a system is 75 full May also be shown as 4000002500000000 or 0x4000002500000000 Severity Info Serviceable No Automatically notify support No Alert Category System Ev...

Страница 270: ...e and clear the log 40000027 00000000 Platform Watchdog Timer expired for arg1 This message is for the use case when an implementation has detected a Platform Watchdog Timer Expired May also be shown as 4000002700000000 or 0x4000002700000000 Severity Error Serviceable No Automatically notify support No Alert Category System OS Timeout SNMP Trap ID 21 CIM Information Prefix IMM ID 0039 User Respons...

Страница 271: ... No Alert Category System other SNMP Trap ID 22 CIM Information Prefix IMM ID 0040 User Response Information only no action is required 40000029 00000000 Security Userid arg1 had arg2 login failures from an SSH client at IP address arg3 This message is for the use case where a user has failed to log in to a Management Controller from SSH May also be shown as 4000002900000000 or 0x4000002900000000 ...

Страница 272: ... has been detected May also be shown as 4000002a00000000 or 0x4000002a00000000 Severity Error Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0042 User Response Reflash the IMM firmware to the latest version 4000002b 00000000 Domain name set to arg1 Domain name set by user May also be shown as 4000002b00000000 or 0x4000002b00...

Страница 273: ...No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0044 User Response Information only no action is required 4000002d 00000000 DDNS setting changed to arg1 by user arg2 DDNS setting changed by user May also be shown as 4000002d00000000 or 0x4000002d00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 004...

Страница 274: ...P Trap ID CIM Information Prefix IMM ID 0046 User Response Information only no action is required 4000002f 00000000 IPv6 enabled by user arg1 IPv6 protocol is enabled by user May also be shown as 4000002f00000000 or 0x4000002f00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0047 User Response Information only no ac...

Страница 275: ...o action is required 40000031 00000000 IPv6 static IP configuration enabled by user arg1 IPv6 static address assignment method is enabled by user May also be shown as 4000003100000000 or 0x4000003100000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0049 User Response Information only no action is required 40000032 000...

Страница 276: ...user arg1 IPv6 statless auto assignment method is enabled by user May also be shown as 4000003300000000 or 0x4000003300000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0051 User Response Information only no action is required 40000034 00000000 IPv6 static IP configuration disabled by user arg1 IPv6 static assignment ...

Страница 277: ...hown as 4000003500000000 or 0x4000003500000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0053 User Response Information only no action is required 40000036 00000000 IPv6 stateless auto configuration disabled by user arg1 IPv6 statless auto assignment method is disabled by user May also be shown as 4000003600000000 or...

Страница 278: ...also be shown as 4000003700000000 or 0x4000003700000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0055 User Response Information only no action is required 40000038 00000000 ENET arg1 IPv6 Static HstName arg2 IP arg3 Pref arg4 GW arg5 IPv6 Static address is active May also be shown as 4000003800000000 or 0x4000003800...

Страница 279: ...4000003900000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0057 User Response Information only no action is required 4000003a 00000000 IPv6 static address of network interface modified from arg1 to arg2 by user arg3 A user modifies the IPv6 static address of a Management Controller May also be shown as 4000003a000000...

Страница 280: ... notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0059 User Response Complete the following steps until the problem is solved 1 Make sure that the IMM network cable is connected 2 Make sure that there is a DHCPv6 server on the network that can assign an IP address to the IMM 4000003c 00000000 Platform Watchdog Timer expired for arg1 An implementation has detected an...

Страница 281: ...em 4000003d 00000000 Telnet port number changed from arg1 to arg2 by user arg3 A user has modified the telnet port number May also be shown as 4000003d00000000 or 0x4000003d00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0061 User Response Information only no action is required 4000003e 00000000 SSH port number ch...

Страница 282: ...May also be shown as 4000003f00000000 or 0x4000003f00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0063 User Response Information only no action is required 40000040 00000000 Web HTTPS port number changed from arg1 to arg2 by user arg3 A user has modified the Web HTTPS port number May also be shown as 400000400000...

Страница 283: ...wn as 4000004100000000 or 0x4000004100000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0065 User Response Information only no action is required 40000042 00000000 CIM XML HTTPS port number changed from arg1 to arg2 by user arg3 A user has modified the CIM HTTPS port number May also be shown as 4000004200000000 or 0x4...

Страница 284: ... or 0x4000004300000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0067 User Response Information only no action is required 40000044 00000000 SNMP Traps port number changed from arg1 to arg2 by user arg3 A user has modified the SNMP Traps port number May also be shown as 4000004400000000 or 0x4000004400000000 Severity...

Страница 285: ... Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0069 User Response Information only no action is required 40000046 00000000 Remote Presence port number changed from arg1 to arg2 by user arg3 A user has modified the Remote Presence port number May also be shown as 4000004600000000 or 0x4000004600000000 Severity Info Serviceable No ...

Страница 286: ...port No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0071 User Response Information only no action is required 40000048 00000000 Inventory data changed for device arg1 new device data hash arg2 new master data hash arg3 Something has caused the physical inventory to change May also be shown as 4000004800000000 or 0x4000004800000000 Severity Info Serviceable No Automatically notif...

Страница 287: ...tify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0073 User Response Information only no action is required 4000004a 00000000 SNMP arg1 disabled by user arg2 A user disabled SNMPv1 or SNMPv3 or Traps May also be shown as 4000004a00000000 or 0x4000004a00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information P...

Страница 288: ...rmation Prefix IMM ID 0075 User Response Information only no action is required 4000004c 00000000 LDAP Server configuration set by user arg1 SelectionMethod arg2 DomainName arg3 Server1 arg4 Server2 arg5 Server3 arg6 Server4 arg7 A user changed the LDAP server configuration May also be shown as 4000004c00000000 or 0x4000004c00000000 Severity Info Serviceable No Automatically notify support No Aler...

Страница 289: ...tify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0077 User Response Information only no action is required 4000004e 00000000 Serial Redirection set by user arg1 Mode arg2 BaudRate arg3 StopBits arg4 Parity arg5 SessionTerminateSequence arg6 A user configured the Serial Port mode May also be shown as 4000004e00000000 or 0x4000004e00000000 Severity Info Serviceable No A...

Страница 290: ... Prefix IMM ID 0079 User Response Information only no action is required 40000050 00000000 Server General Settings set by user arg1 Name arg2 Contact arg3 Location arg4 Room arg5 RackID arg6 Rack U position arg7 A user configured the Location setting May also be shown as 4000005000000000 or 0x4000005000000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Tra...

Страница 291: ...o action is required 40000052 00000000 Server arg1 scheduled for arg2 at arg3 by user arg4 A user configured a Server Power action at a specific time May also be shown as 4000005200000000 or 0x4000005200000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0082 User Response Information only no action is required 40000053...

Страница 292: ...r Power Action May also be shown as 4000005400000000 or 0x4000005400000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0084 User Response Information only no action is required 40000055 00000000 Synchronize time setting by user arg1 Mode arg2 NTPServerHost1 arg3 arg4 NTPServerHost2 arg5 arg6 NTPServerHost3 arg7 arg8 NT...

Страница 293: ...g2 arg3 A user configured the SMTP server May also be shown as 4000005600000000 or 0x4000005600000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0086 User Response Information only no action is required 40000057 00000000 Telnet arg1 by user arg2 A user enables or disables Telnet services May also be shown as 400000570...

Страница 294: ...Server1 arg7 IPv6Server2 arg8 IPv6Server3 arg9 A user configures the DNS servers May also be shown as 4000005800000000 or 0x4000005800000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0088 User Response Information only no action is required 40000059 00000000 LAN over USB arg1 by user arg2 A user configured USB LAN Ma...

Страница 295: ...t forwarding May also be shown as 4000005a00000000 or 0x4000005a00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0090 User Response Information only no action is required 4000005b 00000000 Secure Web services HTTPS arg1 by user arg2 A user enables or disables Secure web services May also be shown as 4000005b0000000...

Страница 296: ... be shown as 4000005c00000000 or 0x4000005c00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0092 User Response Information only no action is required 4000005d 00000000 Secure LDAP arg1 by user arg2 A user enables or disables Secure LDAP services May also be shown as 4000005d00000000 or 0x4000005d00000000 Severity I...

Страница 297: ...e No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0094 User Response Information only no action is required 4000005f 00000000 Server timeouts set by user arg1 EnableOSWatchdog arg2 OSWatchdogTimout arg3 EnableLoaderWatchdog arg4 LoaderTimeout arg5 A user configures Server Timeouts May also be shown as 4000005f00000000 or 0x4000005f00000000 Severity...

Страница 298: ...ity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0096 User Response Information only no action is required 40000061 00000000 License key for arg1 removed by user arg2 A user removes a License Key May also be shown as 4000006100000000 or 0x4000006100000000 Severity Info Serviceable No Automatically notify support No Alert Categor...

Страница 299: ... 0098 User Response Information only no action is required 40000063 00000000 Global Login Account Security set by user arg1 PasswordRequired arg2 PasswordExpirationPeriod arg3 MinimumPasswordReuseCycle arg4 MinimumPasswordLength arg5 MinimumPasswordChangeInterval arg6 MaxmumLoginFailures arg7 LockoutAfterMaxFailures arg8 MinimumDifferentCharacters arg9 DefaultIDExpired arg10 ChangePasswordFirstAcc...

Страница 300: ...erity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0100 User Response Information only no action is required 40000065 00000000 User arg1 removed A user account was deleted May also be shown as 4000006500000000 or 0x4000006500000000 Severity Info Serviceable No Automatically notify support No Alert Category none 288 HX3510 G HX55...

Страница 301: ...eable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0102 User Response Information only no action is required 40000067 00000000 User arg1 role set to arg2 A user account role assigned May also be shown as 4000006700000000 or 0x4000006700000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID Appendix A...

Страница 302: ...SNMP Trap ID CIM Information Prefix IMM ID 0104 User Response Information only no action is required 40000069 00000000 User arg1 for SNMPv3 set AuthenticationProtocol arg2 PrivacyProtocol arg3 AccessType arg4 HostforTraps arg5 User account SNMPv3 settings changed May also be shown as 4000006900000000 or 0x4000006900000000 Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 303: ...ID CIM Information Prefix IMM ID 0106 User Response Information only no action is required 4000006b 00000000 SSH Client key imported for user arg1 from arg2 User imported an SSH Client key May also be shown as 4000006b00000000 or 0x4000006b00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0107 User Response Informat...

Страница 304: ...ontroller arg1 Configuration saved to a file by user arg2 A user saves a Management Controller configuration to a file May also be shown as 4000006d00000000 or 0x4000006d00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0109 User Response Information only no action is required 4000006e 00000000 Alert Configuration G...

Страница 305: ...hod arg3 Address arg4 IncludeLog arg5 Enabled arg6 EnabledAlerts arg7 AllowedFilters arg8 A user adds or updates an Alert Recipient May also be shown as 4000006f00000000 or 0x4000006f00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0111 User Response Information only no action is required 40000070 00000000 SNMP Tra...

Страница 306: ...er arg3 Power Cap values changed by user May also be shown as 4000007100000000 or 0x4000007100000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0113 User Response Information only no action is required 40000072 00000000 The minimum power cap value changed from arg1 watts to arg2 watts Minimum Power Cap value changed M...

Страница 307: ...also be shown as 4000007300000000 or 0x4000007300000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0115 User Response Information only no action is required 40000074 00000000 The soft minimum power cap value changed from arg1 watts to arg2 watts Soft Minimum Power Cap value changed May also be shown as 400000740000000...

Страница 308: ...00 or 0x4000007500000000 Severity Warning Serviceable No Automatically notify support No Alert Category Warning Power SNMP Trap ID 164 CIM Information Prefix IMM ID 0117 User Response Information only no action is required 40000076 00000000 The new minimum power cap value exceeded the power cap value Minimum Power Cap exceeds Power Cap May also be shown as 4000007600000000 or 0x4000007600000000 Se...

Страница 309: ...0000 or 0x4000007700000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0119 User Response Information only no action is required 40000078 00000000 Power capping was deactivated by user arg1 Power capping deactivated by user May also be shown as 4000007800000000 or 0x4000007800000000 Severity Info Serviceable No Automat...

Страница 310: ...rity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0121 User Response Information only no action is required 4000007a 00000000 Static Power Savings mode has been turned off by user arg1 Static Power Savings mode turned off by user May also be shown as 4000007a00000000 or 0x4000007a00000000 Severity Info Serviceable No Automatical...

Страница 311: ...able No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0123 User Response Information only no action is required 4000007c 00000000 Dynamic Power Savings mode has been turned off by user arg1 Dynamic Power Savings mode turned off by user May also be shown as 4000007c00000000 or 0x4000007c00000000 Severity Info Serviceable No Automatically notify suppo...

Страница 312: ...utomatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0125 User Response Information only no action is required 4000007e 00000000 External throttling occurred External throttling occurred May also be shown as 4000007e00000000 or 0x4000007e00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Pr...

Страница 313: ...ormation Prefix IMM ID 0127 User Response Information only no action is required 40000080 00000000 Remote Control session started by user arg1 in arg2 mode Remote Control session started May also be shown as 4000008000000000 or 0x4000008000000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0128 User Response Informatio...

Страница 314: ...0082 00000000 The measured power value has returned below the power cap value Power exceeded cap recovered May also be shown as 4000008200000000 or 0x4000008200000000 Severity Info Serviceable No Automatically notify support No Alert Category Warning Power SNMP Trap ID 164 CIM Information Prefix IMM ID 0130 User Response Information only no action is required 40000083 00000000 The new minimum powe...

Страница 315: ...evel on all nodes A mismatch of IMM firmware has been detected between nodes May also be shown as 4000008400000000 or 0x4000008400000000 Severity Error Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0132 User Response Attempt to flash the IMM firmware to the same level on all nodes 40000085 00000000 FPGA firmware mismatch be...

Страница 316: ... Home Generated by user arg1 Test Call Home generated by user May also be shown as 4000008600000000 or 0x4000008600000000 Severity Info Serviceable No Automatically notify support Yes Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0134 User Response Information only no action is required 40000087 00000000 Manual Call Home by user arg1 arg2 Manual Call Home by user May also be shown...

Страница 317: ...so be shown as 4000008800000000 or 0x4000008800000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0136 User Response Information only no action is required 40000089 00000000 Management Controller arg1 Configuration restoration from a file by user arg2 failed to complete This message is for the use case where a user res...

Страница 318: ... file by user arg2 failed to start This message is for the use case where a user restores a Management Controller configuration from a file and the restoration fails to start May also be shown as 4000008a00000000 or 0x4000008a00000000 Severity Error Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0138 User Response 1 Turn off...

Страница 319: ...esponse Information only no action is required 4000008c 00000000 Security Userid arg1 had arg2 login failures from a CIM client at IP address arg3 This message is for the use case where a user has failed to log in to a Management Controller from CIM May also be shown as 4000008c00000000 or 0x4000008c00000000 Severity Info Serviceable No Automatically notify support No Alert Category System Remote ...

Страница 320: ...fy support No Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0141 User Response Information only no action is required 4000008e 00000000 Device arg1 VPD is not valid The VPD for a device is invalid May also be shown as 4000008e00000000 or 0x4000008e00000000 Severity Warning Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 ...

Страница 321: ...s required 40000090 00000000 The bare metal update application reports a status of arg1 Bare Metal Update Application Status May also be shown as 4000009000000000 or 0x4000009000000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0144 User Response Information only no action is required 40000091 00000000 User...

Страница 322: ...Port arg5 TKLMServer3 arg6 Port arg7 TKLMServer4 arg8 Port arg9 A user configured the TKLM servers May also be shown as 4000009200000000 or 0x4000009200000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0146 User Response Information only no action is required 40000093 00000000 TKLM servers device group set by user arg...

Страница 323: ...lled a self signed certificate for the TKLM client May also be shown as 4000009400000000 or 0x4000009400000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0148 User Response Information only no action is required 40000095 00000000 User arg1 has generated a new encryption key and certificate signing request for the TKLM...

Страница 324: ... client May also be shown as 4000009600000000 or 0x4000009600000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0150 User Response Information only no action is required 40000097 00000000 User arg1 has imported a server certificate for the TKLM server User imported a server certificate for the TKLM Server May also be s...

Страница 325: ...000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0152 User Response Information only no action is required 40000099 00000000 Security Userid arg1 had arg2 login failures from IPMI client at IP address arg3 This message is for the use case where a user has failed to log in to a Management Controller from IPMI May also be...

Страница 326: ...wn as 4000009a00000000 or 0x4000009a00000000 Severity Info Serviceable No Automatically notify support No Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0154 User Response Information only no action is required 4000009b 00000000 Security Userid arg1 had arg2 login failures from IPMI serial client This message is for the use case where a user has failed to log in t...

Страница 327: ...c00000000 or 0x4000009c00000000 Severity Info Serviceable No Automatically notify support No Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0156 User Response Information only no action is required 4000009d 00000000 Login ID arg1 from arg2 at IP address arg3 has logged off This message is for the use case where a user has logged off of a Management Controller May ...

Страница 328: ...x4000009e00000000 Severity Info Serviceable No Automatically notify support No Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0158 User Response Information only no action is required 4000009f 00000000 User arg1 has initiated a TKLM Server Connection Test to check connectivity to server arg2 User initiated a TKLM Server Connection test May also be shown as 4000009...

Страница 329: ...000 or 0x400000a000000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0160 User Response Information only no action is required 400000a1 00000000 UEFI Reported arg1 UEFI audit event logged May also be shown as 400000a100000000 or 0x400000a100000000 Severity Info Serviceable No Automatically notify support No Alert Cate...

Страница 330: ...atically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0162 User Response Information only no action is required 400000a3 00000000 User arg1 has set the SMTP Server reverse path to arg2 User set SMTP Server reverse path address May also be shown as 400000a300000000 or 0x400000a300000000 Severity Info Serviceable No Automatically notify support No Alert...

Страница 331: ...rt No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0164 User Response Information only no action is required 400000a5 00000000 A certificate has been revoked A certificate has been revoked May also be shown as 400000a500000000 or 0x400000a500000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information P...

Страница 332: ... 22 CIM Information Prefix IMM ID 0166 User Response Information only no action is required 400000a7 00000000 The server is restarted by chassis control command Server is restarted by chassis control command May also be shown as 400000a700000000 or 0x400000a700000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ...

Страница 333: ...y no action is required 400000a9 00000000 The server was powered up via power pushbutton Server was power up via power pushbutton May also be shown as 400000a900000000 or 0x400000a900000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0169 User Response Information only no action is required 400000aa 00000000...

Страница 334: ...ver was restarted for OEM reason May also be shown as 400000ab00000000 or 0x400000ab00000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0171 User Response Information only no action is required 400000ac 00000000 The server was automatically powered on because the power restore policy is set to always restor...

Страница 335: ...r was automatically powered on because the power restore policy is set to restore previous power state May also be shown as 400000ad00000000 or 0x400000ad00000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0173 User Response Information only no action is required 400000ae 00000000 The server was reset via P...

Страница 336: ...cled via Platform Event Filter May also be shown as 400000af00000000 or 0x400000af00000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0175 User Response Information only no action is required 400000b0 00000000 The server was soft reset Server was soft reset May also be shown as 400000b000000000 or 0x400000b...

Страница 337: ...er on May also be shown as 400000b100000000 or 0x400000b100000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0177 User Response Information only no action is required 400000b2 00000000 The server was powered off for an unknown reason Server was powered off for an unknown reason May also be shown as 400000b2...

Страница 338: ...00000b300000000 or 0x400000b300000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0179 User Response Information only no action is required 400000b4 00000000 The server was powered off via pushbutton Server was powered off via pushbutton May also be shown as 400000b400000000 or 0x400000b400000000 Severity In...

Страница 339: ...o Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0181 User Response Information only no action is required 400000b6 00000000 The server stayed powered off because the power restore policy is set to always restore Server stayed powered off because the power restore policy is set to always restore May also be shown as 400000b600000000 or 0x4...

Страница 340: ... as 400000b700000000 or 0x400000b700000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0183 User Response Information only no action is required 400000b8 00000000 The server was powered off via Platform Event Filter Server was power off via Platform Event Filter May also be shown as 400000b800000000 or 0x400...

Страница 341: ...tomatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0185 User Response Information only no action is required 400000ba 00000000 Management Controller arg1 reset was initiated due to Power On Reset Management Controller reset was initiated due to Power On Reset May also be shown as 400000ba00000000 or 0x400000ba00000000 Severity Info Serviceable N...

Страница 342: ...pport No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0187 User Response Information only no action is required 400000bc 00000000 Management Controller arg1 reset was initiated by CMM Management Controller reset was initiated by CMM May also be shown as 400000bc00000000 or 0x400000bc00000000 Severity Info Serviceable No Automatically notify support No Alert Category Sy...

Страница 343: ...Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0189 User Response Information only no action is required 400000be 00000000 The arg1 certificate is expired and has been removed Expired certificate has been removed May also be shown as 400000be00000000 or 0x400000be00000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information P...

Страница 344: ...ormation only no action is required 400000c1 00000000 System running in setup System running in setup May also be shown as 400000c100000000 or 0x400000c100000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0193 User Response Information only no action is required 400000c2 00000000 Remote Control session star...

Страница 345: ...ailed to complete arg2 Call Home failed to complete May also be shown as 400000c300000000 or 0x400000c300000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0195 User Response Information only no action is required 400000c4 00000000 IMM failed to log previous event arg1 IMM failed to log a previous event May ...

Страница 346: ...Boot May also be shown as 400000c500000000 or 0x400000c500000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0197 User Response Information only no action is required 400000c6 00000000 UEFI deployment boot mode is enabled for NextAc UEFI deployment boot mode is enabled for NextAC May also be shown as 400000c...

Страница 347: ...e shown as 400000c700000000 or 0x400000c700000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0199 User Response Information only no action is required 400000c9 00000000 User arg1 made system arg2 Encapsulation lite Mode Encapsulation lite mode status change May also be shown as 400000c900000000 or 0x400000c...

Страница 348: ...00 or 0x400000ca00000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0202 User Response Check storage documentation by LSI Event ID 400000cb 00000000 The RAID controller has problem with the battery Please contact technical support to resolve this issue arg1 arg2 arg3 arg4 arg5 The RAID controller has proble...

Страница 349: ...c00000000 Severity Info Serviceable No Automatically notify support Yes Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0204 User Response Check storage documentation by LSI Event ID 400000cd 00000000 The RAID controller detected one or more problems Please contact technical support for additional assistance arg1 arg2 arg3 arg4 arg5 The RAID controller detected one or mor...

Страница 350: ...in the subsystem May also be shown as 400000ce00000000 or 0x400000ce00000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0206 User Response Check storage documentation by LSI Event ID 400000cf 00000000 Enclosure issue detected with one or more units Please check the enclosure units to repair the problem arg1...

Страница 351: ...400000d000000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0208 User Response Lenovo Support will address the problem 400000d1 00000000 Fan problem detected with the enclosure Please check the enclosure unit fan for correct operation arg1 arg2 arg3 arg4 arg5 Fan problem detected with the enclosure May also...

Страница 352: ... Trap ID 22 CIM Information Prefix IMM ID 0210 User Response Lenovo Support will address the problem 400000d3 00000000 One or more virtual drive are in abnormal status that may cause unavailable virtual drive Please check the event logs and if events are targeted to the same disk then replace the drive If necessary contact technical support for additional assistance arg1 arg2 arg3 arg4 arg5 One or...

Страница 353: ...tected one or more possible configuration problem within the subsystem May also be shown as 400000d400000000 or 0x400000d400000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0212 User Response Check storage documentation by LSI Event ID 400000d5 00000000 One or more virtual drive have problem Please contact...

Страница 354: ...Serviceable No Automatically notify support Yes Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0214 User Response Check storage documentation by LSI Event ID 400000d7 00000000 Drive error was detected by RAID controller Please check the event logs and if events are targeted to the same disk then replace the drive If necessary contact technical support for additional assi...

Страница 355: ...shown as 800100020701ffff or 0x800100020701ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Voltage SNMP Trap ID 13 CIM Information Prefix PLAT ID 0476 User Response Replace the system battery 80010202 0701ffff Numeric sensor NumericSensorElementName going low lower critical has asserted CMOS Battery This message is for the use case when an implementatio...

Страница 356: ...Replace the system board n power supply number SysBrd 12V SysBrd 3 3V SysBrd 5V 80010204 1d01ffff Numeric sensor NumericSensorElementName going low lower critical has asserted Fan 1A Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted May also be shown as 800102041d01ffff or 0x800102041d01ffff Severity Error Serviceable Yes Autom...

Страница 357: ...80 User Response 1 Reseat the failing fan n which is indicated by a lit LED near the fan connector on the system board 2 Replace the failing fan n fan number Fan 2B Tach 80010204 1d03ffff Numeric sensor NumericSensorElementName going low lower critical has asserted Fan 3A Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted May al...

Страница 358: ...4ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0480 User Response 1 Reseat the failing fan n which is indicated by a lit LED near the fan connector on the system board 2 Replace the failing fan n fan number Fan 4B Tach 80010204 1d05ffff Numeric sensor NumericSensorElementName going low lower cr...

Страница 359: ...cal has asserted Fan 6A Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted May also be shown as 800102041d06ffff or 0x800102041d06ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0480 User Response 1 Reseat the failing fan n whi...

Страница 360: ...1 Reseat rear hdd cage riser n 2 Remove the following component and identify the problem a HDD drive b HDD cable c RAID card d cage riser n 3 Replace rear hdd cage riser n n riser number 80010204 1d08ffff Numeric sensor NumericSensorElementName going low lower critical has asserted Fan Riser1B Tach This message is for the use case when an implementation has detected a Lower Critical sensor going l...

Страница 361: ...41d09ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0480 User Response 1 Reseat rear hdd cage riser n 2 Remove the following component and identify the problem a HDD drive b HDD cable c RAID card d cage riser n 3 Replace rear hdd cage riser n n riser number 80010204 1d0affff Numeric sensor Numer...

Страница 362: ...RR Amb Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has asserted May also be shown as 800107010701ffff or 0x800107010701ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0490 User Response 1 Make sure that the fans are operating ...

Страница 363: ...490 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow front and rear of the server that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Trained ...

Страница 364: ...d MID2 RR Amb Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has asserted May also be shown as 800107010704ffff or 0x800107010704ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0490 User Response 1 Make sure that the fans are ope...

Страница 365: ...server that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Trained technician only Replace system board 80010701 0706ffff Numeric sensor NumericSensorElementName going high upper non critical h...

Страница 366: ...pper Non critical sensor going high has asserted May also be shown as 800107010707ffff or 0x800107010707ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0490 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow front and rear of the server that the a...

Страница 367: ...s in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Check fan cable on rear HDD cable is connected correctly 4 Check the fans on rear HDD cage are functional 5 Replace rear HDD drive cage 80010701 1401ffff Numeric ...

Страница 368: ...ted May also be shown as 800107011402ffff or 0x800107011402ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0490 User Response 1 Reduce the ambient temperature 2 Ensure the air baffle is installed correctly 3 Check the server airflow Make sure that nothing is blocking the air from coming into or ...

Страница 369: ...ing into or preventing the air from exiting the server 80010701 1404ffff Numeric sensor NumericSensorElementName going high upper non critical has asserted DIMM CD VR Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has asserted May also be shown as 800107011404ffff or 0x800107011404ffff Severity Warning Serviceable Yes Automatically...

Страница 370: ... Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0490 User Response 1 Reduce the ambient temperature 2 Ensure the air baffle is installed correctly 3 Check the server airflow Make sure that nothing is blocking the air from coming into or preventing the air from exiting the server 80010701 1406ffff Numeric sensor NumericSensorElement...

Страница 371: ...rElementName going high upper non critical has asserted PCH Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has asserted May also be shown as 800107012d01ffff or 0x800107012d01ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0490 U...

Страница 372: ...re are no obstructions to the airflow front and rear of the server that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician onl...

Страница 373: ...ted RS2 RR Amb Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109010702ffff or 0x800109010702ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0494 User Response 1 Make sure that the fans are operatin...

Страница 374: ...erver that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Trained technician only Replace system board 80010901 0704ffff Numeric sensor NumericSensorElementName going high upper critical has as...

Страница 375: ...n Upper Critical sensor going high has asserted May also be shown as 800109010705ffff or 0x800109010705ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0494 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow front and rear of the server that the air ...

Страница 376: ...ed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Replace power supply 80010901 0707ffff Numeric sensor NumericSensorElementName going high upper critical has asserted Rear BP1 Temp This message is for the use case when an implementation has de...

Страница 377: ...e when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109010708ffff or 0x800109010708ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0494 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow fro...

Страница 378: ...ambient temperature 2 Ensure the air baffle is installed correctly 3 Check the server airflow Make sure that nothing is blocking the air from coming into or preventing the air from exiting the server 80010901 1402ffff Numeric sensor NumericSensorElementName going high upper critical has asserted CPU2 VR Temp This message is for the use case when an implementation has detected an Upper Critical sen...

Страница 379: ...011403ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0494 User Response 1 Reduce the ambient temperature 2 Ensure the air baffle is installed correctly 3 Check the server airflow Make sure that nothing is blocking the air from coming into or preventing the air from exiting the server 80010901 140...

Страница 380: ...05ffff Numeric sensor NumericSensorElementName going high upper critical has asserted DIMM EF VR Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109011405ffff or 0x800109011405ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM In...

Страница 381: ...perating that there are no obstructions to the airflow front and rear of the server that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Train...

Страница 382: ...nsorElementName going high upper critical has asserted Ambient Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109013701ffff or 0x800109013701ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0494 User...

Страница 383: ...nsor is Planar 3 3V or Planar 5V Trained technician only replace the system board If the specified sensor is Planar 12V complete the following steps until the problem is solved 1 Check power supply n LED 2 Remove the failing power supply 3 Trained technician only Replace the system board n power supply number SysBrd 3 3V SysBrd 5V 80010b01 0701ffff Numeric sensor NumericSensorElementName going hig...

Страница 384: ...emp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has asserted May also be shown as 80010b010702ffff or 0x80010b010702ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0498 User Response 1 Make sure that the fans are operating that th...

Страница 385: ...air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace system board 80010b01 0704ffff Numeric sensor NumericSensorElement...

Страница 386: ...s message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has asserted May also be shown as 80010b010705ffff or 0x80010b010705ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0498 User Response 1 Make sure that the fans are operating that there are...

Страница 387: ... air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace system board 80010b01 0707ffff Numeric sensor NumericSensorElemen...

Страница 388: ... BP2 Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has asserted May also be shown as 80010b010708ffff or 0x80010b010708ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0498 User Response 1 Make sure that the fans are operating t...

Страница 389: ...of the server that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace system board 80010b01 1402ffff Numeric sens...

Страница 390: ...has asserted DIMM AB VR Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has asserted May also be shown as 80010b011403ffff or 0x80010b011403ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0498 User Response 1 Make sure that the f...

Страница 391: ...and rear of the server that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace system board 80010b01 1405ffff Num...

Страница 392: ...has asserted DIMM GH VR Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has asserted May also be shown as 80010b011406ffff or 0x80010b011406ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0498 User Response 1 Make sure that the f...

Страница 393: ...d rear of the server that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace system board 80010b01 3701ffff Numer...

Страница 394: ...ted Sig Verify Fail This message is for the use case when an implementation has detected a Sensor has deasserted May also be shown as 800300062101ffff or 0x800300062101ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0509 User Response No action information only 80030012 2301ffff Sensor SensorElementName has d...

Страница 395: ...e shown as 800300210782ffff or 0x800300210782ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0509 User Response No action information only 80030108 1301ffff Sensor SensorElementName has asserted PS Heavy Load This message is for the use case when an implementation has detected a Sensor has asserted May also b...

Страница 396: ...a Sensor has asserted May also be shown as 8003010c2581ffff or 0x8003010c2581ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0508 User Response 1 Replace as authorized DIMM 2 Please contact sales representative or Lenovo support 8003010f 2101ffff Sensor SensorElementName has asserted IMM FW Corrupted This mes...

Страница 397: ... case when an implementation has detected a Sensor has asserted May also be shown as 800301120601ffff or 0x800301120601ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0508 User Response 1 Replace the power supply with higher rated power 2 Reduce the total power consumption by removing newly added or unused op...

Страница 398: ...sumption by removing newly added or unused option like drives or adapters 8007000d 2582ffff Sensor SensorElementName has transitioned to normal state RAID Vol State This message is for the use case when an implementation has detected a Sensor transition to the normal state May also be shown as 8007000d2582ffff or 0x8007000d2582ffff Severity Info Serviceable No Automatically notify support No Alert...

Страница 399: ...D 0520 User Response 1 Check the microprocessor installed is Intel E5 2690 2 Reduce the ambient temperature under 27 Celsius degree 80070101 2c01ffff Sensor SensorElementName has transitioned from normal to non critical state ML2 OverTemp This message is for the use case when an implementation has detected a Sensor transitioned to non critical from normal May also be shown as 800701012c01ffff or 0...

Страница 400: ...ing Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time ...

Страница 401: ...has transitioned from normal to non critical state I O Resources This message is for the use case when an implementation has detected a Sensor transitioned to non critical from normal May also be shown as 8007010f2582ffff or 0x8007010f2582ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Respo...

Страница 402: ...Response 1 Complete the administrative tasks that require the TPM physical presence switch to be in the ON position 2 Restore the physical presence switch to the OFF position 3 Reboot the system 4 Trained technician only If the error continues replace the planar 80070125 2583ffff Sensor SensorElementName has transitioned from normal to non critical state X8 PCI 1 Config This message is for the use...

Страница 403: ...eable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID CIM Information Prefix PLAT ID 0520 User Response 1 Restart IMM If the error doesn t disappear please proceed step 2 2 Update to the latest level of iMM uEFI code please proceed step 3 3 Replace node 80070201 0301ffff Sensor SensorElementName has transitioned to critical from a less severe state CPU 1 OverTemp This...

Страница 404: ...n only Replace microprocessor n n microprocessor number 80070201 0302ffff Sensor SensorElementName has transitioned to critical from a less severe state CPU 2 OverTemp This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe May also be shown as 800702010302ffff or 0x800702010302ffff Severity Error Serviceable Yes Automatically notify ...

Страница 405: ...AT ID 0522 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow front and rear of the server that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Features and specifications for more information 3 Make s...

Страница 406: ...ian only Replace microprocessor n n microprocessor number 80070201 1103ffff Sensor SensorElementName has transitioned to critical from a less severe state PCI 3 Temp This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe May also be shown as 800702011103ffff or 0x800702011103ffff Severity Error Serviceable Yes Automatically notify su...

Страница 407: ...AT ID 0522 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow front and rear of the server that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Features and specifications for more information 3 Make s...

Страница 408: ...ian only Replace microprocessor n n microprocessor number 80070201 1106ffff Sensor SensorElementName has transitioned to critical from a less severe state PCI 6 Temp This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe May also be shown as 800702011106ffff or 0x800702011106ffff Severity Error Serviceable Yes Automatically notify su...

Страница 409: ...AT ID 0522 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow front and rear of the server that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Features and specifications for more information 3 Make s...

Страница 410: ...nk for microprocessor n is installed correctly 4 Trained technician only Replace microprocessor n n microprocessor number 80070202 0701ffff Sensor SensorElementName has transitioned to critical from a less severe state SysBrd Vol Fault This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe May also be shown as 800702020701ffff or 0x8...

Страница 411: ...800702040a01ffff or 0x800702040a01ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0522 User Response 1 Make sure that there are no obstructions such as bundled cables to the airflow from the power supply fan 2 Replace power supply n n power supply number 80070204 0a02ffff Sensor SensorElementName...

Страница 412: ...2080a01ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0522 User Response 1 Make sure that there are no obstructions such as bundled cables to the airflow from the power supply fan 2 Use the Lenovo Power Configurator utility to ensure current system power consumption is under limitation For more informa...

Страница 413: ...nt system power consumption is under limitation For more information and to download the utility go to https www ibm com support entry myportal docdisplay lndocid LNVO PWRCONF 3 Replace power supply n n power supply number 8007020c 2585ffff Sensor SensorElementName has transitioned to critical from a less severe state nvDIMM Status This message is for the use case when an implementation has detect...

Страница 414: ...t the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 8007020f 2201ffff Sensor SensorElement...

Страница 415: ...d to critical from a less severe state I O Resources This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe May also be shown as 8007020f2582ffff or 0x8007020f2582ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0522 User Response Complete...

Страница 416: ... see Recovering the server firmware 2 If the problem persists trained technician only replace the system board see Removing the system board and Installing the system board 80070219 0701ffff Sensor SensorElementName has transitioned to critical from a less severe state SysBrd Fault This message is for the use case when an implementation has detected a Sensor transitioned to critical from less seve...

Страница 417: ...etected a Sensor transitioned to critical from less severe May also be shown as 8007021b0301ffff or 0x8007021b0301ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0522 User Response 1 Check for a server firmware update 2 Make sure that the installed microprocessors are compatible 3 Make sure the micropr...

Страница 418: ...pansion board 4 Trained technician only Replace microprocessor 2 5 Trained technician only Replace microprocessor 2 expansion board 80070228 2e01ffff Sensor SensorElementName has transitioned to critical from a less severe state ME Error This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe May also be shown as 800702282e01ffff or 0...

Страница 419: ...MP Trap ID 0 CIM Information Prefix PLAT ID 0524 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow front and rear of the server that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and s...

Страница 420: ...nd specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace microprocessor n n microprocessor number 80070301 1101ffff Sensor SensorElementName has transitioned to non recoverable from a less severe state PCI 1 Temp This message is for the use case when an implementation has detected a Sensor transitioned to non recoverable from less...

Страница 421: ... Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0524 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow front and rear of the server that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambien...

Страница 422: ...nd specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace microprocessor n n microprocessor number 80070301 1104ffff Sensor SensorElementName has transitioned to non recoverable from a less severe state PCI 4 Temp This message is for the use case when an implementation has detected a Sensor transitioned to non recoverable from less...

Страница 423: ... Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0524 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow front and rear of the server that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambien...

Страница 424: ...nd specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace microprocessor n n microprocessor number 80070301 1107ffff Sensor SensorElementName has transitioned to non recoverable from a less severe state PCI 7 Temp This message is for the use case when an implementation has detected a Sensor transitioned to non recoverable from less...

Страница 425: ...Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0524 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow front and rear of the server that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient...

Страница 426: ... information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace microprocessor n n microprocessor number 8007030d 2582ffff Sensor SensorElementName has transitioned to non recoverable from a less severe state RAID Vol State This message is for the use case when an implementation has detected a Sensor transitioned to non recoverable from less severe May also be sh...

Страница 427: ...e problem is solved 1 Use the Lenovo Power Configurator utility to determine current system power consumption For more information and to download the utility go to https www ibm com support entry myportal docdisplay lndocid LNVO PWRCONF 2 Follow actions in Power Problems and Solving Power Problems If the specified sensor is PS n 12V OV Fault complete the following steps until the problem is solve...

Страница 428: ...upport entry myportal docdisplay lndocid LNVO PWRCONF 2 Follow actions in Power Problems and Solving Power Problems If the specified sensor is PS n 12V OV Fault complete the following steps until the problem is solved 1 Check power supply n LED 2 Remove the failing power supply 3 Trained technician only Replace the system board n power supply number If the specified sensor is PS n 12V UV Fault com...

Страница 429: ...are see Recovering the server firmware 2 If the problem persists trained technician only replace the system board see Removing the system board and Installing the system board 80070625 2583ffff Sensor SensorElementName has transitioned to non recoverable X8 PCI 1 Config This message is for the use case when an implementation has detected a Sensor transitioned to non recoverable May also be shown a...

Страница 430: ...stem Other SNMP Trap ID CIM Information Prefix PLAT ID 0536 User Response No action information only 80080128 2101ffff Device LogicalDeviceElementName has been added Low Security Jmp This message is for the use case when an implementation has detected a Device was inserted May also be shown as 800801282101ffff or 0x800801282101ffff Severity Info Serviceable No Automatically notify support No Alert...

Страница 431: ... ID 0561 User Response No action information only 800b0108 1301ffff Redundancy Lost for RedundancySetElementName has asserted Power Unit This message is for the use case when Redundancy Lost has asserted May also be shown as 800b01081301ffff or 0x800b01081301ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Redundant Power Supply SNMP Trap ID 9 CIM Informa...

Страница 432: ...onnectors on fan n are not damaged 2 Make sure that the fan n connectors on the system board are not damaged 3 Make sure that the fans are correctly installed 4 Reseat the fans 5 Replace the fans n fan number 800b010a 1e82ffff Redundancy Lost for RedundancySetElementName has asserted Fan Zone 2 This message is for the use case when Redundancy Lost has asserted May also be shown as 800b010a1e82ffff...

Страница 433: ...a1e83ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0802 User Response 1 Make sure that the connectors on fan n are not damaged 2 Make sure that the fan n connectors on the system board are not damaged 3 Make sure that the fans are correctly installed 4 Reseat the fans 5 Replace the fans n fan n...

Страница 434: ...81ffff Redundancy Lost for RedundancySetElementName has asserted Backup Memory This message is for the use case when Redundancy Lost has asserted May also be shown as 800b010c2581ffff or 0x800b010c2581ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0802 User Response 1 If you have added or removed DIM...

Страница 435: ...LAT ID 0806 User Response 1 Non redundant sufficient Power load will be handled by remaining power supply though the system may throttle to avoid a power supply over current condition 2 Please check and reseat the lost power cord or power supply 3 Please replace the failed power supply 800b030c 2581ffff Non redundant Sufficient Resources from Redundancy Degraded or Fully Redundant for RedundancySe...

Страница 436: ... Power Supply SNMP Trap ID 9 CIM Information Prefix PLAT ID 0810 User Response 1 Power load may be handled by remaining power supply The system will attempt to throttle to avoid a power supply over current condition But a system shutdown may happen anyway if the power load is too great 2 Reduce the total power consumption by removing newly added or unused options like drives or adaptors 3 Use the ...

Страница 437: ...at the connectors on fan n are not damaged 2 Make sure that the fan n connectors on the system board are not damaged 3 Make sure that the fans are correctly installed 4 Reseat the fans 5 Replace the fans n fan number 800b050a 1e82ffff Non redundant Insufficient Resources for RedundancySetElementName has asserted Fan Zone 2 This message is for the use case when a Redundancy Set has transitioned to ...

Страница 438: ...ned to Non redundant Insufficient Resources May also be shown as 800b050a1e83ffff or 0x800b050a1e83ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0810 User Response 1 Make sure that the connectors on fan n are not damaged 2 Make sure that the fan n connectors on the system board are not damaged ...

Страница 439: ...connectors on the system board are not damaged 3 Make sure that the fans are correctly installed 4 Reseat the fans 5 Replace the fans n fan number 800b050c 2581ffff Non redundant Insufficient Resources for RedundancySetElementName has asserted Backup Memory This message is for the use case when a Redundancy Set has transitioned to Non redundant Insufficient Resources May also be shown as 800b050c2...

Страница 440: ...ters and standard devices such as Ethernet SCSI and SAS Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 2 Update the firmware UEFI and IMM to the latest level Updating the firmware 3 Run the DSA program 4 Reseat ...

Страница 441: ... the code 2 Update the firmware UEFI and IMM to the latest level Updating the firmware 3 Run the DSA program 4 Reseat the adapter 5 Replace the adapter 6 Trained technician only Replace microprocessor n 7 Trained technician only Replace the system board n microprocessor number 806f0008 0a01ffff PowerSupplyElementName has been added to container PhysicalPackageElementName Power Supply 1 This messag...

Страница 442: ...fy support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0084 User Response No action information only 806f0009 1301ffff PowerSupplyElementName has been turned off Host Power This message is for the use case when an implementation has detected a Power Unit that has been Disabled May also be shown as 806f00091301ffff or 0x806f00091301ffff Severity Info Serviceable No Au...

Страница 443: ...Trap ID 22 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0401ffff The Drive StorageVolumeElementName has been added Drive 1 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0401ffff or 0x806f000d0401ffff Severity Info Serviceable No Automatically notify support No Alert Category System O...

Страница 444: ...se No action information only 806f000d 0403ffff The Drive StorageVolumeElementName has been added Drive 3 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0403ffff or 0x806f000d0403ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0162 U...

Страница 445: ...sage is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0405ffff or 0x806f000d0405ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0406ffff The Drive StorageVolumeElementName has been added Drive ...

Страница 446: ...ed May also be shown as 806f000d0407ffff or 0x806f000d0407ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0408ffff The Drive StorageVolumeElementName has been added Drive 8 This message is for the use case when an implementation has detected a Drive ha...

Страница 447: ...e shown as 806f000d0409ffff or 0x806f000d0409ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 040affff The Drive StorageVolumeElementName has been added Drive 10 This message is for the use case when an implementation has detected a Drive has been Added...

Страница 448: ...fff or 0x806f000d040bffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 040cffff The Drive StorageVolumeElementName has been added Drive 12 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 80...

Страница 449: ... Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 040effff The Drive StorageVolumeElementName has been added Drive 14 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d040effff or 0x806f0...

Страница 450: ...able No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0410ffff The Drive StorageVolumeElementName has been added Drive 16 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0410ffff or 0x806f000d0410ffff Severity I...

Страница 451: ...otify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0412ffff The Drive StorageVolumeElementName has been added Drive 18 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0412ffff or 0x806f000d0412ffff Severity Info Serviceable No Auto...

Страница 452: ...egory System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0414ffff The Drive StorageVolumeElementName has been added Drive 20 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0414ffff or 0x806f000d0414ffff Severity Info Serviceable No Automatically notify support N...

Страница 453: ... 22 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0416ffff The Drive StorageVolumeElementName has been added Drive 22 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0416ffff or 0x806f000d0416ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other S...

Страница 454: ...se No action information only 806f000d 0418ffff The Drive StorageVolumeElementName has been added Drive 24 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0418ffff or 0x806f000d0418ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0162 ...

Страница 455: ...sage is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d041affff or 0x806f000d041affff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 041bffff The Drive StorageVolumeElementName has been added Drive ...

Страница 456: ...ed May also be shown as 806f000d041cffff or 0x806f000d041cffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 041dffff The Drive StorageVolumeElementName has been added Drive 29 This message is for the use case when an implementation has detected a Drive h...

Страница 457: ...e shown as 806f000d041effff or 0x806f000d041effff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 041fffff The Drive StorageVolumeElementName has been added Drive 31 This message is for the use case when an implementation has detected a Drive has been Added...

Страница 458: ...0x806f000d0420ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000f 220101ff The System ComputerSystemElementName has detected no memory in the system ABR Status This message is for the use case when an implementation has detected that memory was detected in...

Страница 459: ...ware on the primary page Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 6 If the problem remains trained technician only replace the system board Firmware Error Sys Boot Status X8 PCI 1 Firm X8 PCI 2 Firm X8 PCI...

Страница 460: ...e the system board Firmware Error Sys Boot Status X8 PCI 1 Firm X8 PCI 2 Firm X8 PCI 6 Firm X8 PCI 7 Firm 806f000f 220103ff The System ComputerSystemElementName encountered firmware error unrecoverable boot device failure ABR Status This message is for the use case when an implementation has detected that System Firmware Error Unrecoverable boot device failure has occurred May also be shown as 806...

Страница 461: ...or code section of the Information Center for the appropriate user response Firmware Error Sys Boot Status X8 PCI 1 Firm X8 PCI 2 Firm X8 PCI 6 Firm X8 PCI 7 Firm 806f000f 220107ff The System ComputerSystemElementName encountered firmware error unrecoverable keyboard failure ABR Status This message is for the use case when an implementation has detected that System Firmware Error Unrecoverable Key...

Страница 462: ... Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0766 User Response This is a UEFI detected event The UEFI POST error code for this event can be found in the logged IMM message text Please refer to the UEFI POST error code in the UEFI POST error code section of the Information Center for the appropriate user response Firmware Error S...

Страница 463: ...Sys Boot Status X8 PCI 1 Firm X8 PCI 2 Firm X8 PCI 6 Firm X8 PCI 7 Firm 806f000f 22010cff CPU voltage mismatch detected on ProcessorElementName ABR Status This message is for the use case when an implementation has detected a CPU voltage mismatch with the socket voltage May also be shown as 806f000f22010cff or 0x806f000f22010cff Severity Error Serviceable Yes Automatically notify support No Alert ...

Страница 464: ...he appropriate user response Firmware Error Sys Boot Status X8 PCI 1 Firm X8 PCI 2 Firm X8 PCI 6 Firm X8 PCI 7 Firm 806f0013 1701ffff A diagnostic interrupt has occurred on system ComputerSystemElementName NMI State This message is for the use case when an implementation has detected a Front Panel NMI Diagnostic Interrupt May also be shown as 806f00131701ffff or 0x806f00131701ffff Severity Error S...

Страница 465: ...ort No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0286 User Response No action information only 806f0021 2201ffff Fault in slot PhysicalConnectorSystemElementName on system ComputerSystemElementName No Op ROM Space This message is for the use case when an implementation has detected a Fault in a slot May also be shown as 806f00212201ffff or 0x806f00212201ffff Severity ...

Страница 466: ...ase when an implementation has detected a Fault in a slot May also be shown as 806f00212582ffff or 0x806f00212582ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0330 User Response 1 Check the PCI LED 2 Reseat the affected adapters and riser card 3 Update the server firmware UEFI and IMM and adapter fi...

Страница 467: ...ortant Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 4 Replace the affected adapters 5 Replace the riser card 6 Trained service technicians only Replace the system board 806f0021 3001ffff Fault in slot PhysicalConnectorS...

Страница 468: ...PCI 1 PCI 2 PCI 3 PCI 4 PCI 5 PCI 6 PCI 7 PCI 8 806f0023 2101ffff Watchdog Timer expired for WatchdogElementName IPMI Watchdog This message is for the use case when an implementation has detected a Watchdog Timer Expired May also be shown as 806f00232101ffff or 0x806f00232101ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information P...

Страница 469: ...ned technician only replace the system board 806f0107 0301ffff An Over Temperature Condition has been detected on ProcessorElementName CPU 1 This message is for the use case when an implementation has detected an Over Temperature Condition Detected for Processor May also be shown as 806f01070301ffff or 0x806f01070301ffff Severity Error Serviceable Yes Automatically notify support No Alert Category...

Страница 470: ...verity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0036 User Response 1 Make sure that the fans are operating There are no obstructions to the airflow front and rear of the server the air baffles are in place and correctly installed and the server cover is installed and completely closed 2 Make sure that th...

Страница 471: ... has failed May also be shown as 806f01080a02ffff or 0x806f01080a02ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0086 User Response 1 Reseat power supply n 2 If the power on LED is not lit and the power supply error LED is lit replace power supply n 3 If both the power on LED and the power supply err...

Страница 472: ...806f010c2001ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support we...

Страница 473: ...correctable error May also be shown as 806f010c2002ffff or 0x806f010c2002ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP...

Страница 474: ...Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 4 If the problem follows the DIMM replace the failing DIMM 5 Trained technician only If the prob...

Страница 475: ...blem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system boar...

Страница 476: ...ins any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the se...

Страница 477: ...technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the ...

Страница 478: ...ed microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the server to the power source and restart the server 9 Trained Service technician only Replace the affected microprocessor 806f010c 2008ffff Uncorrectable error detected for PhysicalMemoryElementName on Sub...

Страница 479: ...etected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 9 This message is for the use case when an implementation has detected a Memory uncorrectable error May also be shown as 806f010c2009ffff or 0x806f010c2009ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response Note ...

Страница 480: ... remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory ch...

Страница 481: ...ogs to a different memory channel or microprocessor 4 If the problem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins f...

Страница 482: ... check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server fir...

Страница 483: ...ed replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 ...

Страница 484: ...aged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the server to the power source and restart the server 9 Trained Service technician only Replace the affecte...

Страница 485: ... reconnect the server to the power source and restart the server 9 Trained Service technician only Replace the affected microprocessor 806f010c 2010ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 16 This message is for the use case when an implementation has detected a Memory uncorrectable error May also be shown as 806f010c2010ffff or 0x806f010c...

Страница 486: ...x806f010c2011ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support w...

Страница 487: ...um code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 4 If the problem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the same DIMM co...

Страница 488: ...blem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system boar...

Страница 489: ...ns any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the ser...

Страница 490: ...technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the ...

Страница 491: ...d microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the server to the power source and restart the server 9 Trained Service technician only Replace the affected microprocessor 806f010c 2017ffff Uncorrectable error detected for PhysicalMemoryElementName on Subs...

Страница 492: ...tected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 24 This message is for the use case when an implementation has detected a Memory uncorrectable error May also be shown as 806f010c2018ffff or 0x806f010c2018ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response Note ...

Страница 493: ...r remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory c...

Страница 494: ...ive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 0401ffff The Dri...

Страница 495: ...ive 2 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0402ffff or 0x806f010d0402ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat ...

Страница 496: ... or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 0404ffff The Drive StorageVolumeElementName has been disabled due to a detected fault D...

Страница 497: ...405ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the follo...

Страница 498: ... a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 0407ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 7 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0407ffff or 0x806f010d0407ffff Severity Error ...

Страница 499: ... Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the ser...

Страница 500: ...etected fault Drive 10 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d040affff or 0x806f010d040affff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on ...

Страница 501: ... or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 040cffff The Drive StorageVolumeElementName has been disabled due to a detected fault D...

Страница 502: ...40dffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the follo...

Страница 503: ... a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 040fffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 15 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d040fffff or 0x806f010d040fffff Severity Error...

Страница 504: ... Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the ser...

Страница 505: ...etected fault Drive 18 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0412ffff or 0x806f010d0412ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on ...

Страница 506: ... or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 0414ffff The Drive StorageVolumeElementName has been disabled due to a detected fault D...

Страница 507: ...415ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the follo...

Страница 508: ... a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 0417ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 23 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0417ffff or 0x806f010d0417ffff Severity Error...

Страница 509: ... Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the ser...

Страница 510: ...etected fault Drive 26 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d041affff or 0x806f010d041affff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on ...

Страница 511: ... or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 041cffff The Drive StorageVolumeElementName has been disabled due to a detected fault D...

Страница 512: ...41dffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the follo...

Страница 513: ... a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 041fffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 31 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d041fffff or 0x806f010d041fffff Severity Error...

Страница 514: ...y support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restartin...

Страница 515: ... board 806f0113 0301ffff A bus timeout has occurred on system ComputerSystemElementName CPU 1 PECI This message is for the use case when an implementation has detected a Bus Timeout May also be shown as 806f01130301ffff or 0x806f01130301ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0224 User Response...

Страница 516: ...0701ffff The connector PhysicalConnectorElementName has encountered a configuration error Front USB This message is for the use case when an implementation has detected an Interconnect Configuration Error May also be shown as 806f011b0701ffff or 0x806f011b0701ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PL...

Страница 517: ...User Response 1 Check system event log is showing LCD cable sensor has deasserted 2 Reseat LCD cable on the system board 3 Reset LCD cable on LCD panel 4 Replace LCD cable 806f0123 2101ffff Reboot of system ComputerSystemElementName initiated by WatchdogElementName IPMI Watchdog This message is for the use case when an implementation has detected a Reboot by a Watchdog occurred May also be shown a...

Страница 518: ...tray installed in the system then the log event is a normal condition If there is a GPU storage tray installed in the system then check the following two portions 1 PDB Power Distribution Board cable is correctly connected from riser card to PDB 2 Replace another PDB cable 806f0125 1001ffff ManagedElementName detected as absent PCI Riser 1 This message is for the use case when an implementation ha...

Страница 519: ...o Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0392 User Response If there is no GPU storage tray installed in the system then the log event is a normal condition If there is a GPU storage tray installed in the system then check the following two portions 1 PDB Power Distribution Board cable is correctly connected from riser...

Страница 520: ...e case when an implementation has detected a Managed Element is Absent May also be shown as 806f01252c01ffff or 0x806f01252c01ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0392 User Response Ensure PCI riser 1 and ML2 card are installed correctly 806f0207 0301ffff ProcessorElementName has Failed with FRB1 B...

Страница 521: ...he adapter 5 Replace the adapter 6 Trained technician only Replace microprocessor n 7 Trained technician only Replace the system board n microprocessor number 806f0207 0302ffff ProcessorElementName has Failed with FRB1 BIST condition CPU 2 This message is for the use case when an implementation has detected a Processor Failed FRB1 BIST condition May also be shown as 806f02070302ffff or 0x806f02070...

Страница 522: ...2072584ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0044 User Response 1 Make sure that the latest levels of firmware and device drivers are installed for all adapters and standard devices such as Ethernet SCSI and SAS Important Some cluster solutions require specific code levels or coordinated code ...

Страница 523: ... or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 0401ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemEl...

Страница 524: ...02ffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the fol...

Страница 525: ...Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 0404ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 4 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0404ffff or 0x806f020d0404ffff Severity Wa...

Страница 526: ... Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the se...

Страница 527: ...terSystemElementName Drive 7 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0407ffff or 0x806f020d0407ffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic tes...

Страница 528: ... or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 0409ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemEl...

Страница 529: ...0affff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the fol...

Страница 530: ...ard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 040cffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 12 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d040cffff or 0x806f020d040cffff Severity Wa...

Страница 531: ... Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the se...

Страница 532: ...erSystemElementName Drive 15 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d040fffff or 0x806f020d040fffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic tes...

Страница 533: ... or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 0411ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemEl...

Страница 534: ...12ffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the fol...

Страница 535: ...ard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 0414ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 20 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0414ffff or 0x806f020d0414ffff Severity Wa...

Страница 536: ... Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the se...

Страница 537: ...erSystemElementName Drive 23 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0417ffff or 0x806f020d0417ffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic tes...

Страница 538: ... or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 0419ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemEl...

Страница 539: ...1affff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the fol...

Страница 540: ...ard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 041cffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 28 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d041cffff or 0x806f020d041cffff Severity Wa...

Страница 541: ... Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the se...

Страница 542: ...erSystemElementName Drive 31 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d041fffff or 0x806f020d041fffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic tes...

Страница 543: ...t 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f0223 2101ffff Powering off system ComputerSystemElementName initiated by WatchdogE...

Страница 544: ...Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0100 User Response 1 Reconnect the power cords 2 Check power supply n LED 3 See Power supply LEDs for more information n power supply number 806f0308 0a02ffff PowerSupplyElementName has lost input Power Supply 2 This message is for the use case when an implementation has detected a Power Supply that has input that has been los...

Страница 545: ...0136 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Make sure that the DIMMs are firmly seated and no foreign material is...

Страница 546: ...remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Make sure that the DIMMs are firmly seated and no foreign material is found in the DIMM connector Then retry with the ...

Страница 547: ...re that the DIMMs are firmly seated and no foreign material is found in the DIMM connector Then retry with the same DIMM 4 If the problem is related to a DIMM replace the failing DIMM indicated by the error LEDs 5 If the problem occurs on the same DIMM connector swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microproces...

Страница 548: ...cated by the error LEDs 5 If the problem occurs on the same DIMM connector swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system boar...

Страница 549: ...ted by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 7 Trained service technician only Remove the affected microprocessor and check the microprocessor socket p...

Страница 550: ...ferent memory channel or microprocessor 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 7 Trained service technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system boa...

Страница 551: ...lace the system board 7 Trained service technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 8 Trained service technician only If the problem is related to microprocessor socket pins replace the system board 806f030c 2008ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryEleme...

Страница 552: ...entName on Subsystem MemoryElementName DIMM 9 This message is for the use case when an implementation has detected a Memory Scrub failure May also be shown as 806f030c2009ffff or 0x806f030c2009ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response Note Each time you install or remove a DIM...

Страница 553: ...remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Make sure that the DIMMs are firmly seated and no foreign material is found in the DIMM connector Then retry with the ...

Страница 554: ...re that the DIMMs are firmly seated and no foreign material is found in the DIMM connector Then retry with the same DIMM 4 If the problem is related to a DIMM replace the failing DIMM indicated by the error LEDs 5 If the problem occurs on the same DIMM connector swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microproces...

Страница 555: ...ated by the error LEDs 5 If the problem occurs on the same DIMM connector swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board...

Страница 556: ...ted by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 7 Trained service technician only Remove the affected microprocessor and check the microprocessor socket p...

Страница 557: ...erent memory channel or microprocessor 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 7 Trained service technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system boar...

Страница 558: ...lace the system board 7 Trained service technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 8 Trained service technician only If the problem is related to microprocessor socket pins replace the system board 806f030c 2010ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryEleme...

Страница 559: ...ntName on Subsystem MemoryElementName DIMM 17 This message is for the use case when an implementation has detected a Memory Scrub failure May also be shown as 806f030c2011ffff or 0x806f030c2011ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response Note Each time you install or remove a DIM...

Страница 560: ...remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Make sure that the DIMMs are firmly seated and no foreign material is found in the DIMM connector Then retry with the ...

Страница 561: ...re that the DIMMs are firmly seated and no foreign material is found in the DIMM connector Then retry with the same DIMM 4 If the problem is related to a DIMM replace the failing DIMM indicated by the error LEDs 5 If the problem occurs on the same DIMM connector swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microproces...

Страница 562: ...ated by the error LEDs 5 If the problem occurs on the same DIMM connector swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board...

Страница 563: ...ted by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 7 Trained service technician only Remove the affected microprocessor and check the microprocessor socket p...

Страница 564: ...erent memory channel or microprocessor 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 7 Trained service technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system boar...

Страница 565: ...lace the system board 7 Trained service technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 8 Trained service technician only If the problem is related to microprocessor socket pins replace the system board 806f030c 2018ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryEleme...

Страница 566: ...tName on Subsystem MemoryElementName All DIMMS This message is for the use case when an implementation has detected a Memory Scrub failure May also be shown as 806f030c2581ffff or 0x806f030c2581ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response Note Each time you install or remove a DI...

Страница 567: ...temElementName Drive 0 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d0400ffff or 0x806f030d0400ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 0401ffff Hot Spare enabled for ...

Страница 568: ... Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 0403ffff Hot Spare enabled for ComputerSystemElementName Drive 3 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d0403ffff or 0x806f030d0403ffff Severity Info Ser...

Страница 569: ...pport No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 0405ffff Hot Spare enabled for ComputerSystemElementName Drive 5 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d0405ffff or 0x806f030d0405ffff Severity Info Serviceable No Automaticall...

Страница 570: ...MP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 0407ffff Hot Spare enabled for ComputerSystemElementName Drive 7 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d0407ffff or 0x806f030d0407ffff Severity Info Serviceable No Automatically notify support No Alert Category Syst...

Страница 571: ...nse No action information only 806f030d 0409ffff Hot Spare enabled for ComputerSystemElementName Drive 9 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d0409ffff or 0x806f030d0409ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170...

Страница 572: ...e is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d040bffff or 0x806f030d040bffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 040cffff Hot Spare enabled for ComputerSystemElementName Drive 12...

Страница 573: ...ed May also be shown as 806f030d040dffff or 0x806f030d040dffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 040effff Hot Spare enabled for ComputerSystemElementName Drive 14 This message is for the use case when an implementation has detected a Hot Spare ha...

Страница 574: ...e shown as 806f030d040fffff or 0x806f030d040fffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 0410ffff Hot Spare enabled for ComputerSystemElementName Drive 16 This message is for the use case when an implementation has detected a Hot Spare has been Enable...

Страница 575: ...fff or 0x806f030d0411ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 0412ffff Hot Spare enabled for ComputerSystemElementName Drive 18 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 8...

Страница 576: ... Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 0414ffff Hot Spare enabled for ComputerSystemElementName Drive 20 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d0414ffff or 0x806f...

Страница 577: ...able No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 0416ffff Hot Spare enabled for ComputerSystemElementName Drive 22 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d0416ffff or 0x806f030d0416ffff Severity ...

Страница 578: ... notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 0418ffff Hot Spare enabled for ComputerSystemElementName Drive 24 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d0418ffff or 0x806f030d0418ffff Severity Info Serviceable No A...

Страница 579: ...Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 041affff Hot Spare enabled for ComputerSystemElementName Drive 26 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d041affff or 0x806f030d041affff Severity Info Serviceable No Automatically notify suppo...

Страница 580: ... ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 041cffff Hot Spare enabled for ComputerSystemElementName Drive 28 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d041cffff or 0x806f030d041cffff Severity Info Serviceable No Automatically notify support No Alert Category System Oth...

Страница 581: ...nse No action information only 806f030d 041effff Hot Spare enabled for ComputerSystemElementName Drive 30 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d041effff or 0x806f030d041effff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 017...

Страница 582: ...entName Ext Drive This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d0420ffff or 0x806f030d0420ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f0313 1701ffff A software NMI has occurred...

Страница 583: ... UEFI and IMM 806f0323 2101ffff Power cycle of system ComputerSystemElementName initiated by watchdog WatchdogElementName IPMI Watchdog This message is for the use case when an implementation has detected a Power Cycle by Watchdog occurred May also be shown as 806f03232101ffff or 0x806f03232101ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap I...

Страница 584: ... the suggested actions for that error event and restart the server 3 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the ToolsCenter Suite CLI 806f040c 2002ffff PhysicalMemoryElementName Disabled...

Страница 585: ...806f040c2003ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the server 3 ...

Страница 586: ...emory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the ToolsCenter Suite CLI 806f040c 2005ffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 5 This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2005f...

Страница 587: ...tify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the server 3 Check the Lenovo support website for an applicable retain tip ...

Страница 588: ...ElementName DIMM 8 This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2008ffff or 0x806f040c2008ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled...

Страница 589: ... the suggested actions for that error event and restart the server 3 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the ToolsCenter Suite CLI 806f040c 200affff PhysicalMemoryElementName Disabled...

Страница 590: ...806f040c200bffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the server 3 ...

Страница 591: ...mory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the ToolsCenter Suite CLI 806f040c 200dffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 13 This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c200df...

Страница 592: ...tify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the server 3 Check the Lenovo support website for an applicable retain tip ...

Страница 593: ...ElementName DIMM 16 This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2010ffff or 0x806f040c2010ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disable...

Страница 594: ... the suggested actions for that error event and restart the server 3 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the ToolsCenter Suite CLI 806f040c 2012ffff PhysicalMemoryElementName Disabled...

Страница 595: ...806f040c2013ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the server 3 ...

Страница 596: ...mory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the ToolsCenter Suite CLI 806f040c 2015ffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 21 This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2015f...

Страница 597: ...tify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the server 3 Check the Lenovo support website for an applicable retain tip ...

Страница 598: ...ElementName DIMM 24 This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2018ffff or 0x806f040c2018ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disable...

Страница 599: ...low the suggested actions for that error event and restart the server 3 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the ToolsCenter Suite CLI One of the DIMMs 806f0413 2582ffff A PCI PERR has...

Страница 600: ...smatch has occurred May also be shown as 806f05070301ffff or 0x806f05070301ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0062 User Response 1 Check the CPU LED See more information about the CPU LED in Light path diagnostics 2 Check for a server firmware update Important Some cluster solutions require ...

Страница 601: ...coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 3 Make sure that the installed microprocessors are compatible with each other 4 Trained technician only Reseat microprocessor n 5 Trained technician only Replace microprocessor n n microprocessor number 806f0507 2584ffff Processo...

Страница 602: ...e DIMM 1 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2001ffff or 0x806f050c2001ffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response Note Each time you install or remove a DIMM you must ...

Страница 603: ...l or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memor...

Страница 604: ...ent logs to a different memory channel or microprocessor 4 If the error still occurs on the same DIMM replace the affected DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microproces...

Страница 605: ...occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 806f050c 2005ffff Memory...

Страница 606: ...chnician only Replace the affected microprocessor 806f050c 2006ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 6 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2006ffff or 0x806f050c2006ffff Severity Warning Serviceable Yes Automatically notify suppo...

Страница 607: ...l or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memor...

Страница 608: ...ent logs to a different memory channel or microprocessor 4 If the error still occurs on the same DIMM replace the affected DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microproces...

Страница 609: ...occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 806f050c 200affff Memory...

Страница 610: ...hnician only Replace the affected microprocessor 806f050c 200bffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 11 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c200bffff or 0x806f050c200bffff Severity Warning Serviceable Yes Automatically notify suppo...

Страница 611: ...l or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memor...

Страница 612: ...ent logs to a different memory channel or microprocessor 4 If the error still occurs on the same DIMM replace the affected DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microproces...

Страница 613: ...occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 806f050c 200fffff Memory...

Страница 614: ...hnician only Replace the affected microprocessor 806f050c 2010ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 16 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2010ffff or 0x806f050c2010ffff Severity Warning Serviceable Yes Automatically notify suppo...

Страница 615: ...l or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memor...

Страница 616: ...ent logs to a different memory channel or microprocessor 4 If the error still occurs on the same DIMM replace the affected DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microproces...

Страница 617: ...occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 806f050c 2014ffff Memory...

Страница 618: ...hnician only Replace the affected microprocessor 806f050c 2015ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 21 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2015ffff or 0x806f050c2015ffff Severity Warning Serviceable Yes Automatically notify suppo...

Страница 619: ...l or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memor...

Страница 620: ...ent logs to a different memory channel or microprocessor 4 If the error still occurs on the same DIMM replace the affected DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microproces...

Страница 621: ...ccurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 806f050c 2581ffff Memory ...

Страница 622: ...ssor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor One of the DIMMs 806f050d 0400ffff Array ComputerSystemElementName is in critical condition Drive 0 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0...

Страница 623: ...ware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d 0402ffff Array ComputerSystemElementName is in critical condition Drive 2 This message is for the use case when an implementation has detected that an Arr...

Страница 624: ... Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID ada...

Страница 625: ...cated by a lit status LED 806f050d 0405ffff Array ComputerSystemElementName is in critical condition Drive 5 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0405ffff or 0x806f050d0405ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Pr...

Страница 626: ... Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d 0407ffff Array ComputerSystemElementName...

Страница 627: ...8 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0408ffff or 0x806f050d0408ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are...

Страница 628: ...ive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d 040affff Array ComputerSystemElementName is in critical condition Drive 10 This message is for the use case when an implementation has detected th...

Страница 629: ...040bffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the ...

Страница 630: ...rd disk drive that is indicated by a lit status LED 806f050d 040dffff Array ComputerSystemElementName is in critical condition Drive 13 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d040dffff or 0x806f050d040dffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP T...

Страница 631: ...itical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d...

Страница 632: ...ndition Drive 16 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0410ffff or 0x806f050d0410ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk dri...

Страница 633: ...ive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d 0412ffff Array ComputerSystemElementName is in critical condition Drive 18 This message is for the use case when an implementation has detected th...

Страница 634: ...0413ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the ...

Страница 635: ...rd disk drive that is indicated by a lit status LED 806f050d 0415ffff Array ComputerSystemElementName is in critical condition Drive 21 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0415ffff or 0x806f050d0415ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP T...

Страница 636: ...itical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d...

Страница 637: ...ndition Drive 24 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0418ffff or 0x806f050d0418ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk dri...

Страница 638: ...ive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d 041affff Array ComputerSystemElementName is in critical condition Drive 26 This message is for the use case when an implementation has detected th...

Страница 639: ...041bffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the ...

Страница 640: ...rd disk drive that is indicated by a lit status LED 806f050d 041dffff Array ComputerSystemElementName is in critical condition Drive 29 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d041dffff or 0x806f050d041dffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP T...

Страница 641: ...itical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d...

Страница 642: ...dition Ext Drive This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0420ffff or 0x806f050d0420ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk dri...

Страница 643: ... or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 4 Make sure that the adapter is supported For a list of supported optional devices see http www lenovo com serverproven 5 Remove both adapters 6 Replace the PCIe adapters 7 Replace the riser card 806f052b 2101ffff Invalid or ...

Страница 644: ...em goes away 5 If the problem remains trained service technician replace the system board 806f0607 0301ffff An SM BIOS Uncorrectable CPU complex error for ProcessorElementName has asserted CPU 1 This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted May also be shown as 806f06070301ffff or 0x806f06070301ffff Severity Error Serviceable Yes Automatically notify...

Страница 645: ...her see Installing a microprocessor and heat sink for information about microprocessor requirements 2 Update the server firmware to the latest level see Updating the firmware 3 Trained technician only Replace the incompatible microprocessor 806f0607 2584ffff An SM BIOS Uncorrectable CPU complex error for ProcessorElementName has asserted All CPUs This message is for the use case when an SM BIOS Un...

Страница 646: ... with a Configuration Error May also be shown as 806f06081301ffff or 0x806f06081301ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0104 User Response 1 Make sure that the power supplies installed are with the same rating or wattage 2 Reinstall the power supplies with the same rating or wattage 806f060d ...

Страница 647: ... an implementation has detected that an Array Failed May also be shown as 806f060d0401ffff or 0x806f060d0401ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the S...

Страница 648: ...e sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 0403ffff Array ComputerSystemElementName has failed Drive 3 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0403ffff or 0x806f060d0403ffff Severity Erro...

Страница 649: ...utomatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit statu...

Страница 650: ...led Drive 6 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0406ffff or 0x806f060d0406ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmwa...

Страница 651: ...ive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 0408ffff Array ComputerSystemElementName has failed Drive 8 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d04...

Страница 652: ...le Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a l...

Страница 653: ...iled Drive 11 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d040bffff or 0x806f060d040bffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firm...

Страница 654: ...rd disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 040dffff Array ComputerSystemElementName has failed Drive 13 This message is for the use case when an implementation has detected that an Array Failed May also be shown as...

Страница 655: ...y Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is...

Страница 656: ...has failed Drive 16 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0410ffff or 0x806f060d0410ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk driv...

Страница 657: ...rd disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 0412ffff Array ComputerSystemElementName has failed Drive 18 This message is for the use case when an implementation has detected that an Array Failed May also be shown as...

Страница 658: ...y Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is...

Страница 659: ...has failed Drive 21 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0415ffff or 0x806f060d0415ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk driv...

Страница 660: ...rd disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 0417ffff Array ComputerSystemElementName has failed Drive 23 This message is for the use case when an implementation has detected that an Array Failed May also be shown as...

Страница 661: ...y Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is...

Страница 662: ...has failed Drive 26 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d041affff or 0x806f060d041affff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk driv...

Страница 663: ...rd disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 041cffff Array ComputerSystemElementName has failed Drive 28 This message is for the use case when an implementation has detected that an Array Failed May also be shown as...

Страница 664: ...y Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is...

Страница 665: ...has failed Drive 31 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d041fffff or 0x806f060d041fffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk driv...

Страница 666: ...e are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f070c 2001ffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 1 This message is for the use case when an implementation has detected a Memory DIMM configuratio...

Страница 667: ...omatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2003ffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 3 This message is for the use case when an implementation has ...

Страница 668: ...ror Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2005ffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 5 This message is for the use case when...

Страница 669: ...r 0x806f070c2006ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2007ffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 7 This ...

Страница 670: ...wn as 806f070c2008ffff or 0x806f070c2008ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2009ffff Configuration Error for PhysicalMemoryElementName on Subsystem Memory...

Страница 671: ...May also be shown as 806f070c200affff or 0x806f070c200affff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 200bffff Configuration Error for PhysicalMemoryElementName on S...

Страница 672: ...onfiguration error has been corrected May also be shown as 806f070c200cffff or 0x806f070c200cffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 200dffff Configuration Er...

Страница 673: ...IMM 14 This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected May also be shown as 806f070c200effff or 0x806f070c200effff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct s...

Страница 674: ...nd technology 806f070c 2010ffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 16 This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected May also be shown as 806f070c2010ffff or 0x806f070c2010ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNM...

Страница 675: ...User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2012ffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 18 This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected May also be shown as 806f070c2012ffff or 0x806f07...

Страница 676: ...t Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2014ffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 20 This message is for the use case when an implementation has detected a Memory DIMM configura...

Страница 677: ...omatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2016ffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 22 This message is for the use case when an implementation has...

Страница 678: ...ror Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2018ffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 24 This message is for the use case whe...

Страница 679: ...581ffff or 0x806f070c2581ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology One of the DIMMs 806f070d 0400ffff Rebuild in progress for Array in system ComputerSystemElementName D...

Страница 680: ... 806f070d0401ffff or 0x806f070d0401ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0402ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 2 This message is for the use case when an implementation has detected that an Array Rebuil...

Страница 681: ...shown as 806f070d0403ffff or 0x806f070d0403ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0404ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 4 This message is for the use case when an implementation has detected that an Arra...

Страница 682: ...also be shown as 806f070d0405ffff or 0x806f070d0405ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0406ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 6 This message is for the use case when an implementation has detected that...

Страница 683: ...ss May also be shown as 806f070d0407ffff or 0x806f070d0407ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0408ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 8 This message is for the use case when an implementation has detect...

Страница 684: ...ogress May also be shown as 806f070d0409ffff or 0x806f070d0409ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 040affff Rebuild in progress for Array in system ComputerSystemElementName Drive 10 This message is for the use case when an implementation has d...

Страница 685: ...rogress May also be shown as 806f070d040bffff or 0x806f070d040bffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 040cffff Rebuild in progress for Array in system ComputerSystemElementName Drive 12 This message is for the use case when an implementation has ...

Страница 686: ...rogress May also be shown as 806f070d040dffff or 0x806f070d040dffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 040effff Rebuild in progress for Array in system ComputerSystemElementName Drive 14 This message is for the use case when an implementation has ...

Страница 687: ...rogress May also be shown as 806f070d040fffff or 0x806f070d040fffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0410ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 16 This message is for the use case when an implementation has ...

Страница 688: ...rogress May also be shown as 806f070d0411ffff or 0x806f070d0411ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0412ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 18 This message is for the use case when an implementation has ...

Страница 689: ...rogress May also be shown as 806f070d0413ffff or 0x806f070d0413ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0414ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 20 This message is for the use case when an implementation has ...

Страница 690: ...rogress May also be shown as 806f070d0415ffff or 0x806f070d0415ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0416ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 22 This message is for the use case when an implementation has ...

Страница 691: ...rogress May also be shown as 806f070d0417ffff or 0x806f070d0417ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0418ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 24 This message is for the use case when an implementation has ...

Страница 692: ...rogress May also be shown as 806f070d0419ffff or 0x806f070d0419ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 041affff Rebuild in progress for Array in system ComputerSystemElementName Drive 26 This message is for the use case when an implementation has ...

Страница 693: ...rogress May also be shown as 806f070d041bffff or 0x806f070d041bffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 041cffff Rebuild in progress for Array in system ComputerSystemElementName Drive 28 This message is for the use case when an implementation has ...

Страница 694: ...rogress May also be shown as 806f070d041dffff or 0x806f070d041dffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 041effff Rebuild in progress for Array in system ComputerSystemElementName Drive 30 This message is for the use case when an implementation has ...

Страница 695: ...ogress May also be shown as 806f070d041fffff or 0x806f070d041fffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0420ffff Rebuild in progress for Array in system ComputerSystemElementName Ext Drive This message is for the use case when an implementation has ...

Страница 696: ...May also be shown as 806f072b2101ffff or 0x806f072b2101ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0450 User Response No action information only IMM Recovery 806f072b 2201ffff A successful software or firmware change was detected on system ComputerSystemElementName Bkup Auto Update This message is for the...

Страница 697: ...sabled May also be shown as 806f08070301ffff or 0x806f08070301ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0061 User Response No action information only 806f0807 0302ffff ProcessorElementName has been Disabled CPU 2 This message is for the use case when an implementation has detected a Processor has been D...

Страница 698: ...84ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0061 User Response No action information only One of the CPUs 806f080c 2001ffff Memory sparing initiated for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 1 This message is for the use case when an implementation has detected that Memory double...

Страница 699: ...shown as 806f080c2002ffff or 0x806f080c2002ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0140 User Response No action information only 806f080c 2003ffff Memory sparing initiated for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 3 This message is for the use case when an implementation has de...

Страница 700: ...also be shown as 806f080c2004ffff or 0x806f080c2004ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0140 User Response No action information only 806f080c 2005ffff Memory sparing initiated for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 5 This message is for the use case when an implementatio...

Страница 701: ...ed May also be shown as 806f080c2006ffff or 0x806f080c2006ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0140 User Response No action information only 806f080c 2007ffff Memory sparing initiated for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 7 This message is for the use case when an implem...

Страница 702: ...itiated May also be shown as 806f080c2008ffff or 0x806f080c2008ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0140 User Response No action information only 806f080c 2009ffff Memory sparing initiated for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 9 This message is for the use case when an i...

Страница 703: ...itiated May also be shown as 806f080c200affff or 0x806f080c200affff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0140 User Response No action information only 806f080c 200bffff Memory sparing initiated for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 11 This message is for the use case when an ...

Страница 704: ...itiated May also be shown as 806f080c200cffff or 0x806f080c200cffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0140 User Response No action information only 806f080c 200dffff Memory sparing initiated for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 13 This message is for the use case when an ...

Страница 705: ...itiated May also be shown as 806f080c200effff or 0x806f080c200effff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0140 User Response No action information only 806f080c 200fffff Memory sparing initiated for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 15 This message is for the use case when an ...

Страница 706: ...itiated May also be shown as 806f080c2010ffff or 0x806f080c2010ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0140 User Response No action information only 806f080c 2011ffff Memory sparing initiated for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 17 This message is for the use case when an ...

Страница 707: ...itiated May also be shown as 806f080c2012ffff or 0x806f080c2012ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0140 User Response No action information only 806f080c 2013ffff Memory sparing initiated for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 19 This message is for the use case when an ...

Страница 708: ...itiated May also be shown as 806f080c2014ffff or 0x806f080c2014ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0140 User Response No action information only 806f080c 2015ffff Memory sparing initiated for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 21 This message is for the use case when an ...

Страница 709: ...itiated May also be shown as 806f080c2016ffff or 0x806f080c2016ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0140 User Response No action information only 806f080c 2017ffff Memory sparing initiated for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 23 This message is for the use case when an ...

Страница 710: ...tiated May also be shown as 806f080c2018ffff or 0x806f080c2018ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0140 User Response No action information only 806f080c 2581ffff Memory sparing initiated for PhysicalMemoryElementName on Subsystem MemoryElementName All DIMMS This message is for the use case when an...

Страница 711: ...cally notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0240 User Response 1 Check the system event log 2 Check the DIMM error LEDs 3 Remove the failing DIMM from the system board 4 Check for a server firmware update Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution ver...

Страница 712: ...a server firmware update Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 5 Trained technician only Replace the system board 806f0813 2584ffff An Uncorrectable Bus Error has occurred on system ComputerSystemElemen...

Страница 713: ...y Replace the system board 806f0823 2101ffff Watchdog Timer interrupt occurred for WatchdogElementName IPMI Watchdog This message is for the use case when an implementation has detected a Watchdog Timer interrupt occurred May also be shown as 806f08232101ffff or 0x806f08232101ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information ...

Страница 714: ...ge is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c2002ffff or 0x806f090c2002ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2003ffff P...

Страница 715: ... DIMM n n DIMM number 806f090c 2004ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 4 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c2004ffff or 0x806f090c2004ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix...

Страница 716: ...ix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2006ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 6 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c2006ffff or 0x806f090c2006ffff Severity Warning Serviceable Yes Automatically...

Страница 717: ...Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2008ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 8 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c2008ffff or 0...

Страница 718: ...Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 200affff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 10 This message is for the use case when an implementation has detected Memory has been Thr...

Страница 719: ...c200bffff or 0x806f090c200bffff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 200cffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 12 This message is for the use case when a...

Страница 720: ...tected Memory has been Throttled May also be shown as 806f090c200dffff or 0x806f090c200dffff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 200effff PhysicalMemoryElementName on Subsystem MemoryElementN...

Страница 721: ...MemoryElementName on Subsystem MemoryElementName Throttled DIMM 15 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c200fffff or 0x806f090c200fffff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM a...

Страница 722: ...ix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2011ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 17 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c2011ffff or 0x806f090c2011ffff Severity Warning Serviceable Yes Automaticall...

Страница 723: ...Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2013ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 19 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c2013ffff or ...

Страница 724: ... Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2015ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 21 This message is for the use case when an implementation has detected Memory has been Th...

Страница 725: ...c2016ffff or 0x806f090c2016ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2017ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 23 This message is for the use case when a...

Страница 726: ...cted Memory has been Throttled May also be shown as 806f090c2018ffff or 0x806f090c2018ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f0a07 0301ffff ProcessorElementName is operating in a Degraded State C...

Страница 727: ...ature You must be operating within the specifications 3 Make sure that the heat sink for microprocessor n is installed correctly 4 Trained technician only Replace microprocessor n n microprocessor number 806f0a07 0302ffff ProcessorElementName is operating in a Degraded State CPU 2 This message is for the use case when an implementation has detected a Processor is running in the Degraded state May ...

Страница 728: ...6f0a0c2001ffff or 0x806f0a0c2001ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow that the air baffles are in place and correctly installed and that the server cover is installed and completely c...

Страница 729: ...fan has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2003ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 3 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2003ffff or 0x806...

Страница 730: ...iceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Make sure that ambient temperature is within the...

Страница 731: ...er Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 6 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2006ffff or 0x806f0a0c2006ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temper...

Страница 732: ...Prefix PLAT ID 0146 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Make sure that ambient temperature is within the specifications 3 If a fan has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f...

Страница 733: ...ame on Subsystem MemoryElementName DIMM 9 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2009ffff or 0x806f0a0c2009ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1...

Страница 734: ...ere are no obstructions to the airflow that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Make sure that ambient temperature is within the specifications 3 If a fan has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 200bffff An Over Temperature Condition has been detected on the PhysicalMemo...

Страница 735: ... DIMM 12 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c200cffff or 0x806f0a0c200cffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure that the fans are oper...

Страница 736: ...rflow that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Make sure that ambient temperature is within the specifications 3 If a fan has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 200effff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem Memory...

Страница 737: ...emperature Condition for Memory that has been Detected May also be shown as 806f0a0c200fffff or 0x806f0a0c200fffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow that the air baffles are in place a...

Страница 738: ...server cover is installed and completely closed 2 Make sure that ambient temperature is within the specifications 3 If a fan has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2011ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 17 This message is for the use case when an implementation h...

Страница 739: ...s 806f0a0c2012ffff or 0x806f0a0c2012ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow that the air baffles are in place and correctly installed and that the server cover is installed and complete...

Страница 740: ...is within the specifications 3 If a fan has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2014ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 20 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also ...

Страница 741: ...y Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Make sure that ambient temperature i...

Страница 742: ...an has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2017ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 23 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2017ffff or 0x806...

Страница 743: ...or 0x806f0a0c2018ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Make su...

Страница 744: ...or May also be shown as 806f0a130302ffff or 0x806f0a130302ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0244 User Response 1 Reseat the microprocessor and then restart the server 2 Replace microprocessor n n microprocessor number 81010002 0701ffff Numeric sensor NumericSensorElementName going low low...

Страница 745: ...ssage is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted May also be shown as 810102020701ffff or 0x810102020701ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Voltage SNMP Trap ID 1 CIM Information Prefix PLAT ID 0481 User Response No action information only SysBrd 12V SysBrd 3 3V SysBrd 5V 81010204 1d...

Страница 746: ... Fan 1B Tach 81010204 1d02ffff Numeric sensor NumericSensorElementName going low lower critical has deasserted Fan 2A Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted May also be shown as 810102041d02ffff or 0x810102041d02ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Fan Failure SN...

Страница 747: ...x PLAT ID 0481 User Response No action information only Fan 3B Tach 81010204 1d04ffff Numeric sensor NumericSensorElementName going low lower critical has deasserted Fan 4A Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted May also be shown as 810102041d04ffff or 0x810102041d04ffff Severity Info Serviceable No Automatically n...

Страница 748: ...x PLAT ID 0481 User Response No action information only Fan 5B Tach 81010204 1d06ffff Numeric sensor NumericSensorElementName going low lower critical has deasserted Fan 6A Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted May also be shown as 810102041d06ffff or 0x810102041d06ffff Severity Info Serviceable No Automatically n...

Страница 749: ...mation Prefix PLAT ID 0481 User Response No action information only 81010204 1d08ffff Numeric sensor NumericSensorElementName going low lower critical has deasserted Fan Riser1B Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted May also be shown as 810102041d08ffff or 0x810102041d08ffff Severity Info Serviceable No Automatica...

Страница 750: ...mation Prefix PLAT ID 0481 User Response No action information only 81010204 1d0affff Numeric sensor NumericSensorElementName going low lower critical has deasserted Fan Riser2B Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted May also be shown as 810102041d0affff or 0x810102041d0affff Severity Info Serviceable No Automatica...

Страница 751: ...mation Prefix PLAT ID 0491 User Response No action information only 81010701 0702ffff Numeric sensor NumericSensorElementName going high upper non critical has deasserted RS2 RR Amb Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has deasserted May also be shown as 810107010702ffff or 0x810107010702ffff Severity Info Serviceable No ...

Страница 752: ...mation Prefix PLAT ID 0491 User Response No action information only 81010701 0704ffff Numeric sensor NumericSensorElementName going high upper non critical has deasserted MID2 RR Amb Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has deasserted May also be shown as 810107010704ffff or 0x810107010704ffff Severity Info Serviceable No...

Страница 753: ...rmation Prefix PLAT ID 0491 User Response No action information only 81010701 0706ffff Numeric sensor NumericSensorElementName going high upper non critical has deasserted PSU FR Amb Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has deasserted May also be shown as 810107010706ffff or 0x810107010706ffff Severity Info Serviceable No...

Страница 754: ...mation Prefix PLAT ID 0491 User Response No action information only 81010701 0708ffff Numeric sensor NumericSensorElementName going high upper non critical has deasserted Rear BP2 Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has deasserted May also be shown as 810107010708ffff or 0x810107010708ffff Severity Info Serviceable No Au...

Страница 755: ...mation Prefix PLAT ID 0491 User Response No action information only 81010701 1402ffff Numeric sensor NumericSensorElementName going high upper non critical has deasserted CPU2 VR Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has deasserted May also be shown as 810107011402ffff or 0x810107011402ffff Severity Info Serviceable No Aut...

Страница 756: ...mation Prefix PLAT ID 0491 User Response No action information only 81010701 1404ffff Numeric sensor NumericSensorElementName going high upper non critical has deasserted DIMM CD VR Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has deasserted May also be shown as 810107011404ffff or 0x810107011404ffff Severity Info Serviceable No ...

Страница 757: ...mation Prefix PLAT ID 0491 User Response No action information only 81010701 1406ffff Numeric sensor NumericSensorElementName going high upper non critical has deasserted DIMM GH VR Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has deasserted May also be shown as 810107011406ffff or 0x810107011406ffff Severity Info Serviceable No ...

Страница 758: ...tion Prefix PLAT ID 0491 User Response No action information only 81010701 3701ffff Numeric sensor NumericSensorElementName going high upper non critical has deasserted Ambient Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has deasserted May also be shown as 810107013701ffff or 0x810107013701ffff Severity Info Serviceable No Autom...

Страница 759: ...mation Prefix PLAT ID 0495 User Response No action information only 81010901 0702ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted RS2 RR Amb Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted May also be shown as 810109010702ffff or 0x810109010702ffff Severity Info Serviceable No Automati...

Страница 760: ...mation Prefix PLAT ID 0495 User Response No action information only 81010901 0704ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted MID2 RR Amb Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted May also be shown as 810109010704ffff or 0x810109010704ffff Severity Info Serviceable No Automat...

Страница 761: ...rmation Prefix PLAT ID 0495 User Response No action information only 81010901 0706ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted PSU FR Amb Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted May also be shown as 810109010706ffff or 0x810109010706ffff Severity Info Serviceable No Automat...

Страница 762: ...mation Prefix PLAT ID 0495 User Response No action information only 81010901 0708ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted Rear BP2 Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted May also be shown as 810109010708ffff or 0x810109010708ffff Severity Info Serviceable No Automatica...

Страница 763: ...mation Prefix PLAT ID 0495 User Response No action information only 81010901 1402ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted CPU2 VR Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted May also be shown as 810109011402ffff or 0x810109011402ffff Severity Info Serviceable No Automatical...

Страница 764: ...mation Prefix PLAT ID 0495 User Response No action information only 81010901 1404ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted DIMM CD VR Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted May also be shown as 810109011404ffff or 0x810109011404ffff Severity Info Serviceable No Automati...

Страница 765: ...mation Prefix PLAT ID 0495 User Response No action information only 81010901 1406ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted DIMM GH VR Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted May also be shown as 810109011406ffff or 0x810109011406ffff Severity Info Serviceable No Automati...

Страница 766: ...tion Prefix PLAT ID 0495 User Response No action information only 81010901 3701ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted Ambient Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted May also be shown as 810109013701ffff or 0x810109013701ffff Severity Info Serviceable No Automatically...

Страница 767: ...0495 User Response No action information only SysBrd 3 3V SysBrd 5V 81010b01 0701ffff Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted RS1 RR Amb Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b010701ffff or 0x81010b010701ffff Severity Info Serviceab...

Страница 768: ...mation Prefix PLAT ID 0499 User Response No action information only 81010b01 0703ffff Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted MID1 RR Amb Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b010703ffff or 0x81010b010703ffff Severity Info Servicea...

Страница 769: ...mation Prefix PLAT ID 0499 User Response No action information only 81010b01 0705ffff Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted RAID RR Amb Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b010705ffff or 0x81010b010705ffff Severity Info Servicea...

Страница 770: ...rmation Prefix PLAT ID 0499 User Response No action information only 81010b01 0707ffff Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted Rear BP1 Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b010707ffff or 0x81010b010707ffff Severity Info Serviceabl...

Страница 771: ...rmation Prefix PLAT ID 0499 User Response No action information only 81010b01 1401ffff Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted CPU1 VR Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b011401ffff or 0x81010b011401ffff Severity Info Serviceable...

Страница 772: ...ation Prefix PLAT ID 0499 User Response No action information only 81010b01 1403ffff Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted DIMM AB VR Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b011403ffff or 0x81010b011403ffff Severity Info Serviceabl...

Страница 773: ...mation Prefix PLAT ID 0499 User Response No action information only 81010b01 1405ffff Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted DIMM EF VR Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b011405ffff or 0x81010b011405ffff Severity Info Serviceab...

Страница 774: ...nformation Prefix PLAT ID 0499 User Response No action information only 81010b01 2d01ffff Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted PCH Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b012d01ffff or 0x81010b012d01ffff Severity Info Serviceable ...

Страница 775: ...y Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0499 User Response No action information only 81030006 2101ffff Sensor SensorElementName has asserted Sig Verify Fail This message is for the use case when an implementation has detected a Sensor has asserted May also be shown as 810300062101ffff or 0x810300062101ffff Severity Info Serviceable No Automatically notify support No A...

Страница 776: ...ff Sensor SensorElementName has asserted PCIe Dev LK Down This message is for the use case when an implementation has detected a Sensor has asserted May also be shown as 810300210782ffff or 0x810300210782ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0508 User Response No action information only 81030108 130...

Страница 777: ...ion has detected a Sensor has deasserted May also be shown as 8103010c2581ffff or 0x8103010c2581ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0509 User Response No action information only 81030112 0601ffff Sensor SensorElementName has deasserted SMM Mode This message is for the use case when an implementati...

Страница 778: ... or 0x810301210782ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0509 User Response No action information only 81070101 0c01ffff Sensor SensorElementName has deasserted the transition from normal to non critical state Ambient Status This message is for the use case when an implementation has detected that a ...

Страница 779: ...l May also be shown as 810701012c01ffff or 0x810701012c01ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0521 User Response No action information only 8107010d 2582ffff Sensor SensorElementName has deasserted the transition from normal to non critical state RAID Vol State This message is for the use...

Страница 780: ...ormal May also be shown as 8107010f2201ffff or 0x8107010f2201ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0521 User Response No action information only 8107010f 2582ffff Sensor SensorElementName has deasserted the transition from normal to non critical state I O Resources This message is for the use ca...

Страница 781: ...own as 810701252583ffff or 0x810701252583ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0521 User Response No action information only X8 PCI 2 Config X8 PCI 6 Config X8 PCI 7 Config 81070128 2e01ffff Sensor SensorElementName has deasserted the transition from normal to non critical state ME Recovery This...

Страница 782: ...ical May also be shown as 810702010301ffff or 0x810702010301ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0523 User Response No action information only 81070201 0302ffff Sensor SensorElementName has transitioned to a less severe state from critical CPU 2 OverTemp This message is for the use case w...

Страница 783: ...ritical May also be shown as 810702011101ffff or 0x810702011101ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0523 User Response No action information only 81070201 1102ffff Sensor SensorElementName has transitioned to a less severe state from critical PCI 2 Temp This message is for the use case wh...

Страница 784: ...ritical May also be shown as 810702011103ffff or 0x810702011103ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0523 User Response No action information only 81070201 1104ffff Sensor SensorElementName has transitioned to a less severe state from critical PCI 4 Temp This message is for the use case wh...

Страница 785: ...ritical May also be shown as 810702011105ffff or 0x810702011105ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0523 User Response No action information only 81070201 1106ffff Sensor SensorElementName has transitioned to a less severe state from critical PCI 6 Temp This message is for the use case wh...

Страница 786: ...ritical May also be shown as 810702011107ffff or 0x810702011107ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0523 User Response No action information only 81070201 1108ffff Sensor SensorElementName has transitioned to a less severe state from critical PCI 8 Temp This message is for the use case wh...

Страница 787: ...m critical May also be shown as 810702020701ffff or 0x810702020701ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Voltage SNMP Trap ID 1 CIM Information Prefix PLAT ID 0523 User Response No action information only 81070204 0a01ffff Sensor SensorElementName has transitioned to a less severe state from critical PS 1 Fan Fault This message is for the use case...

Страница 788: ...itical May also be shown as 810702040a02ffff or 0x810702040a02ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0523 User Response No action information only 81070208 0a01ffff Sensor SensorElementName has transitioned to a less severe state from critical PS 1 Therm Fault This message is for the use c...

Страница 789: ...critical May also be shown as 810702080a02ffff or 0x810702080a02ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0523 User Response No action information only 8107020c 2585ffff Sensor SensorElementName has transitioned to a less severe state from critical nvDIMM Status This message is for the use case when...

Страница 790: ...ritical May also be shown as 8107020d2582ffff or 0x8107020d2582ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0523 User Response No action information only 8107020f 2201ffff Sensor SensorElementName has transitioned to a less severe state from critical TXT ACM Module This message is for the use case whe...

Страница 791: ...re from critical May also be shown as 8107020f2582ffff or 0x8107020f2582ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0523 User Response No action information only 81070214 2201ffff Sensor SensorElementName has transitioned to a less severe state from critical TPM Lock This message is for the use case ...

Страница 792: ...tical May also be shown as 810702190701ffff or 0x810702190701ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0523 User Response No action information only 8107021b 0301ffff Sensor SensorElementName has transitioned to a less severe state from critical CPU 1 QPILinkErr This message is for the use case whe...

Страница 793: ...om critical May also be shown as 8107021b0302ffff or 0x8107021b0302ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0523 User Response No action information only 81070228 2e01ffff Sensor SensorElementName has transitioned to a less severe state from critical ME Error This message is for the use case when ...

Страница 794: ...s deasserted May also be shown as 810703010301ffff or 0x810703010301ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0525 User Response No action information only 81070301 0302ffff Sensor SensorElementName has deasserted the transition to non recoverable from a less severe state CPU 2 OverTemp This m...

Страница 795: ...sserted May also be shown as 810703011101ffff or 0x810703011101ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0525 User Response No action information only 81070301 1102ffff Sensor SensorElementName has deasserted the transition to non recoverable from a less severe state PCI 2 Temp This message is...

Страница 796: ...sserted May also be shown as 810703011103ffff or 0x810703011103ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0525 User Response No action information only 81070301 1104ffff Sensor SensorElementName has deasserted the transition to non recoverable from a less severe state PCI 4 Temp This message is...

Страница 797: ...sserted May also be shown as 810703011105ffff or 0x810703011105ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0525 User Response No action information only 81070301 1106ffff Sensor SensorElementName has deasserted the transition to non recoverable from a less severe state PCI 6 Temp This message is...

Страница 798: ...sserted May also be shown as 810703011107ffff or 0x810703011107ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0525 User Response No action information only 81070301 1108ffff Sensor SensorElementName has deasserted the transition to non recoverable from a less severe state PCI 8 Temp This message is...

Страница 799: ...serted May also be shown as 810703012c01ffff or 0x810703012c01ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0525 User Response No action information only 8107030d 2582ffff Sensor SensorElementName has deasserted the transition to non recoverable from a less severe state RAID Vol State This message...

Страница 800: ... as 810706080a01ffff or 0x810706080a01ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0531 User Response No action information only PS1 12V OV Fault PS1 12V UV Fault PS1 12Vaux Fault 81070608 0a02ffff Sensor SensorElementName has deasserted the transition to non recoverable PS2 12V OC Fault This message i...

Страница 801: ...sor transition to non recoverable has deasserted May also be shown as 810706252583ffff or 0x810706252583ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0531 User Response No action information only X8 PCI 2 Config X8 PCI 6 Config X8 PCI 7 Config 810b010a 1e81ffff Redundancy Lost for RedundancySetElementN...

Страница 802: ...ed May also be shown as 810b010a1e82ffff or 0x810b010a1e82ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0803 User Response No action information only 810b010a 1e83ffff Redundancy Lost for RedundancySetElementName has deasserted Fan Zone 3 This message is for the use case when Redundacy Lost has d...

Страница 803: ...lso be shown as 810b010a1e84ffff or 0x810b010a1e84ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0803 User Response No action information only 810b010c 2581ffff Redundancy Lost for RedundancySetElementName has deasserted Backup Memory This message is for the use case when Redundacy Lost has deasse...

Страница 804: ... shown as 810b03091301ffff or 0x810b03091301ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Redundant Power Supply SNMP Trap ID 10 CIM Information Prefix PLAT ID 0807 User Response No action information only 810b030c 2581ffff Non redundant Sufficient Resources from Redundancy Degraded or Fully Redundant for RedundancySetElementName has deasserted Backup Mem...

Страница 805: ... also be shown as 810b05091301ffff or 0x810b05091301ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Redundant Power Supply SNMP Trap ID 9 CIM Information Prefix PLAT ID 0811 User Response No action information only 810b050a 1e81ffff Non redundant Insufficient Resources for RedundancySetElementName has deasserted Fan Zone 1 This message is for the use case ...

Страница 806: ...sources May also be shown as 810b050a1e82ffff or 0x810b050a1e82ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0811 User Response No action information only 810b050a 1e83ffff Non redundant Insufficient Resources for RedundancySetElementName has deasserted Fan Zone 3 This message is for the use case...

Страница 807: ...urces May also be shown as 810b050a1e84ffff or 0x810b050a1e84ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0811 User Response No action information only 810b050c 2581ffff Non redundant Insufficient Resources for RedundancySetElementName has deasserted Backup Memory This message is for the use cas...

Страница 808: ...tion May also be shown as 816f00070301ffff or 0x816f00070301ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0043 User Response No action information only 816f0007 0302ffff ProcessorElementName has Recovered from IERR CPU 2 This message is for the use case when an implementation has detected a Processor Rec...

Страница 809: ...oved May also be shown as 816f00080a01ffff or 0x816f00080a01ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0085 User Response No action information only 816f0008 0a02ffff PowerSupplyElementName has been removed from container PhysicalPackageElementName Power Supply 2 This message is for the use case when an ...

Страница 810: ... as 816f00091301ffff or 0x816f00091301ffff Severity Info Serviceable No Automatically notify support No Alert Category System Power On SNMP Trap ID 24 CIM Information Prefix PLAT ID 0107 User Response No action information only 816f000d 0400ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 0 This message is for the use case when an implementation h...

Страница 811: ... removed from unit PhysicalPackageElementName Drive 1 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0401ffff or 0x816f000d0401ffff Severity Info Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard di...

Страница 812: ...ard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Replace backplane 816f000d 0403ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 3 This message is for the use case when an implementati...

Страница 813: ... or 0x816f000d0404ffff Severity Info Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level...

Страница 814: ...e 816f000d 0406ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 6 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0406ffff or 0x816f000d0406ffff Severity Info Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix ...

Страница 815: ...P Trap ID 22 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Replace backplane 816f000d 0408ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackage...

Страница 816: ...implementation has detected a Drive has been Removed May also be shown as 816f000d0409ffff or 0x816f000d0409ffff Severity Info Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk dri...

Страница 817: ...ce the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Replace backplane 816f000d 040bffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 11 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d040bffff or 0x816f000d040bffff...

Страница 818: ...le Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Replace backplane 816f000d 040dffff The Dri...

Страница 819: ...PhysicalPackageElementName Drive 14 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d040effff or 0x816f000d040effff Severity Info Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wa...

Страница 820: ... hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Replace backplane 816f000d 0410ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 16 This message is for the use case when an implementation has detected a...

Страница 821: ...6f000d0411ffff Severity Info Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Repla...

Страница 822: ...ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 19 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0413ffff or 0x816f000d0413ffff Severity Info Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0163 U...

Страница 823: ...ation Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Replace backplane 816f000d 0415ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 21 Th...

Страница 824: ...ay also be shown as 816f000d0416ffff or 0x816f000d0416ffff Severity Info Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID control...

Страница 825: ...k firmware and RAID controller firmware are at the latest level 4 Replace backplane 816f000d 0418ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 24 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0418ffff or 0x816f000d0418ffff Severity Info Serviceable Yes Automatically no...

Страница 826: ... Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Replace backplane 816f000d 041affff The Drive...

Страница 827: ...ysicalPackageElementName Drive 27 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d041bffff or 0x816f000d041bffff Severity Info Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait...

Страница 828: ...sk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Replace backplane 816f000d 041dffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 29 This message is for the use case when an implementation has detected a Drive h...

Страница 829: ...f Severity Info Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Replace backplane ...

Страница 830: ...removed from unit PhysicalPackageElementName Ext Drive This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0420ffff or 0x816f000d0420ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard di...

Страница 831: ...85 User Response No action information only Firmware Error Sys Boot Status X8 PCI 1 Firm X8 PCI 2 Firm X8 PCI 6 Firm X8 PCI 7 Firm 816f0013 1701ffff System ComputerSystemElementName has recovered from a diagnostic interrupt NMI State This message is for the use case when an implementation has detected a recovery from a Front Panel NMI Diagnostic Interrupt May also be shown as 816f00131701ffff or 0...

Страница 832: ...rt Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0331 User Response No action information only 816f0021 2582ffff Fault condition removed on slot PhysicalConnectorElementName on system ComputerSystemElementName All PCI Error This message is for the use case when an implementation has detected a Fault condition in a slot has been removed May also be shown as 816f00212582ffff...

Страница 833: ...ally notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0331 User Response No action information only 816f0021 3001ffff Fault condition removed on slot PhysicalConnectorElementName on system ComputerSystemElementName Internal RAID This message is for the use case when an implementation has detected a Fault condition in a slot has been removed May also be...

Страница 834: ...erity Info Serviceable No Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0399 User Response No action information only 816f0107 0301ffff An Over Temperature Condition has been removed on ProcessorElementName CPU 1 This message is for the use case when an implementation has detected a Over Temperature Condition has been Removed for Proces...

Страница 835: ... Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0037 User Response No action information only 816f0108 0a01ffff PowerSupplyElementName has returned to OK status Power Supply 1 This message is for the use case when an implementation has detected a Power Supply return to normal operational status May also be shown as 816f01080a01ffff...

Страница 836: ...upport No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0087 User Response No action information only 816f010c 2001ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 1 This message is for the use case when an implementation has detected a Memory uncorrectable error recovery May also be shown as 816f010c2001ffff...

Страница 837: ...tomatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2003ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 3 This message is for the use case when an implementation has detected a Memory uncorrectable error recovery May also be sho...

Страница 838: ...rviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2005ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 5 This message is for the use case when an implementation has detected a Memory uncorrectable error recovery ...

Страница 839: ...everity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2007ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 7 This message is for the use case when an implementation has detected a Memory uncorrectable ...

Страница 840: ...008ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2009ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 9 This message is for the use case when an implementation has detected a Memory uncor...

Страница 841: ...f or 0x816f010c200affff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 200bffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 11 This message is for the use case when an implementation has detect...

Страница 842: ... 816f010c200cffff or 0x816f010c200cffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 200dffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 13 This message is for the use case when an implement...

Страница 843: ...shown as 816f010c200effff or 0x816f010c200effff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 200fffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 15 This message is for the use case when an i...

Страница 844: ...also be shown as 816f010c2010ffff or 0x816f010c2010ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2011ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 17 This message is for the use case w...

Страница 845: ...ry May also be shown as 816f010c2012ffff or 0x816f010c2012ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2013ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 19 This message is for the use...

Страница 846: ...ecovery May also be shown as 816f010c2014ffff or 0x816f010c2014ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2015ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 21 This message is for th...

Страница 847: ...ecovery May also be shown as 816f010c2016ffff or 0x816f010c2016ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2017ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 23 This message is for th...

Страница 848: ...covery May also be shown as 816f010c2018ffff or 0x816f010c2018ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2581ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName All DIMMS This message is for t...

Страница 849: ...bled May also be shown as 816f010d0400ffff or 0x816f010d0400ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0401ffff The Drive StorageVolumeElementName has been enabled Drive 1 This message is for the use case when an implementation has dete...

Страница 850: ...own as 816f010d0402ffff or 0x816f010d0402ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0403ffff The Drive StorageVolumeElementName has been enabled Drive 3 This message is for the use case when an implementation has detected a Drive was En...

Страница 851: ... or 0x816f010d0404ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0405ffff The Drive StorageVolumeElementName has been enabled Drive 5 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown...

Страница 852: ... Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0407ffff The Drive StorageVolumeElementName has been enabled Drive 7 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d0407ffff or 0x816f010d04...

Страница 853: ...y notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0409ffff The Drive StorageVolumeElementName has been enabled Drive 9 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d0409ffff or 0x816f010d0409ffff Severity Info Service...

Страница 854: ... Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 040bffff The Drive StorageVolumeElementName has been enabled Drive 11 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d040bffff or 0x816f010d040bffff Severity Info Serviceable No Automatically no...

Страница 855: ... Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 040dffff The Drive StorageVolumeElementName has been enabled Drive 13 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d040dffff or 0x816f010d040dffff Severity Info Serviceable No Automatically notify support No Alert Category Critical...

Страница 856: ...e No action information only 816f010d 040fffff The Drive StorageVolumeElementName has been enabled Drive 15 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d040fffff or 0x816f010d040fffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT...

Страница 857: ...ssage is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d0411ffff or 0x816f010d0411ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0412ffff The Drive StorageVolumeElementName has been ena...

Страница 858: ...ed May also be shown as 816f010d0413ffff or 0x816f010d0413ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0414ffff The Drive StorageVolumeElementName has been enabled Drive 20 This message is for the use case when an implementation has detec...

Страница 859: ...e shown as 816f010d0415ffff or 0x816f010d0415ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0416ffff The Drive StorageVolumeElementName has been enabled Drive 22 This message is for the use case when an implementation has detected a Drive w...

Страница 860: ...fff or 0x816f010d0417ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0418ffff The Drive StorageVolumeElementName has been enabled Drive 24 This message is for the use case when an implementation has detected a Drive was Enabled May also be s...

Страница 861: ... Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 041affff The Drive StorageVolumeElementName has been enabled Drive 26 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d041affff ...

Страница 862: ...o Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 041cffff The Drive StorageVolumeElementName has been enabled Drive 28 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d041cffff or 0x816f010d041cffff Severi...

Страница 863: ...rt No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 041effff The Drive StorageVolumeElementName has been enabled Drive 30 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d041effff or 0x816f010d041effff Severity Info Serviceable No Autom...

Страница 864: ...al Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0420ffff The Drive StorageVolumeElementName has been enabled Ext Drive This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d0420ffff or 0x816f010d0420ffff Severity Info Serviceable No Automatically notify support No...

Страница 865: ...MP Trap ID 50 CIM Information Prefix PLAT ID 0187 User Response No action information only 816f0113 0301ffff System ComputerSystemElementName has recovered from a bus timeout CPU 1 PECI This message is for the use case when an implemenation has detected that a system has recovered from a Bus Timeout May also be shown as 816f01130301ffff or 0x816f01130301ffff Severity Info Serviceable No Automatica...

Страница 866: ...rviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0225 User Response 1 Trained technician only Replace microprocessor n see Removing a microprocessor and heat sink and Replacing a microprocessor and heat sink 2 If the problem persists and there is no other CPU with the same error indication replace the system board 3 Trained t...

Страница 867: ... was Repaired May also be shown as 816f011b0c01ffff or 0x816f011b0c01ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0267 User Response No action information only 816f011b 2586ffff The connector PhysicalConnectorElementName configuration error has been repaired nvDIMM Cable This message is for the use ca...

Страница 868: ...esent May also be shown as 816f01250c01ffff or 0x816f01250c01ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0390 User Response No action information only 816f0125 1001ffff ManagedElementName detected as present PCI Riser 1 This message is for the use case when an implementation has detected a Managed Element...

Страница 869: ...y also be shown as 816f01251002ffff or 0x816f01251002ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0390 User Response No action information only 816f0125 100bffff ManagedElementName detected as present PDB Card This message is for the use case when an implementation has detected a Managed Element is now Pre...

Страница 870: ...1252c01ffff or 0x816f01252c01ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0390 User Response No action information only 816f0207 0301ffff ProcessorElementName has Recovered from FRB1 BIST condition CPU 1 This message is for the use case when an implementation has detected a Processor Recovered FRB1 BIST co...

Страница 871: ...816f02070302ffff or 0x816f02070302ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0045 User Response No action information only 816f0207 2584ffff ProcessorElementName has Recovered from FRB1 BIST condition All CPUs This message is for the use case when an implementation has detected a Processor Recovered F...

Страница 872: ...as 816f020d0400ffff or 0x816f020d0400ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0401ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 1 This message is for the use case when an...

Страница 873: ...shown as 816f020d0402ffff or 0x816f020d0402ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0403ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 3 This message is for the use case w...

Страница 874: ...also be shown as 816f020d0404ffff or 0x816f020d0404ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0405ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 5 This message is for the us...

Страница 875: ...ed May also be shown as 816f020d0406ffff or 0x816f020d0406ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0407ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 7 This message is for...

Страница 876: ...edicted May also be shown as 816f020d0408ffff or 0x816f020d0408ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0409ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 9 This message i...

Страница 877: ...edicted May also be shown as 816f020d040affff or 0x816f020d040affff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 040bffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 11 This message ...

Страница 878: ...edicted May also be shown as 816f020d040cffff or 0x816f020d040cffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 040dffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 13 This message ...

Страница 879: ...edicted May also be shown as 816f020d040effff or 0x816f020d040effff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 040fffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 15 This message ...

Страница 880: ...edicted May also be shown as 816f020d0410ffff or 0x816f020d0410ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0411ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 17 This message ...

Страница 881: ...edicted May also be shown as 816f020d0412ffff or 0x816f020d0412ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0413ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 19 This message ...

Страница 882: ...edicted May also be shown as 816f020d0414ffff or 0x816f020d0414ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0415ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 21 This message ...

Страница 883: ...edicted May also be shown as 816f020d0416ffff or 0x816f020d0416ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0417ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 23 This message ...

Страница 884: ...edicted May also be shown as 816f020d0418ffff or 0x816f020d0418ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0419ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 25 This message ...

Страница 885: ...edicted May also be shown as 816f020d041affff or 0x816f020d041affff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 041bffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 27 This message ...

Страница 886: ...edicted May also be shown as 816f020d041cffff or 0x816f020d041cffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 041dffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 29 This message ...

Страница 887: ...edicted May also be shown as 816f020d041effff or 0x816f020d041effff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 041fffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 31 This message ...

Страница 888: ...nger Predicted May also be shown as 816f020d0420ffff or 0x816f020d0420ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f0308 0a01ffff PowerSupplyElementName has returned to a Normal Input State Power Supply 1 This message is for the use case when ...

Страница 889: ...to normal May also be shown as 816f03080a02ffff or 0x816f03080a02ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0099 User Response No action information only 816f030c 2001ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 1 This message is for the use case when...

Страница 890: ...ry May also be shown as 816f030c2002ffff or 0x816f030c2002ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2003ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 3 This message is for the use case when ...

Страница 891: ...also be shown as 816f030c2004ffff or 0x816f030c2004ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2005ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 5 This message is for the use case when an impl...

Страница 892: ...shown as 816f030c2006ffff or 0x816f030c2006ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2007ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 7 This message is for the use case when an implementati...

Страница 893: ... 816f030c2008ffff or 0x816f030c2008ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2009ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 9 This message is for the use case when an implementation has d...

Страница 894: ...f or 0x816f030c200affff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 200bffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 11 This message is for the use case when an implementation has detected a Memor...

Страница 895: ...00cffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 200dffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 13 This message is for the use case when an implementation has detected a Memory Scrub failure ...

Страница 896: ...everity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 200fffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 15 This message is for the use case when an implementation has detected a Memory Scrub failure recovery ...

Страница 897: ...rviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2011ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 17 This message is for the use case when an implementation has detected a Memory Scrub failure recovery May also be sho...

Страница 898: ...tomatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2013ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 19 This message is for the use case when an implementation has detected a Memory Scrub failure recovery May also be shown as 816f030c2...

Страница 899: ...lly notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2015ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 21 This message is for the use case when an implementation has detected a Memory Scrub failure recovery May also be shown as 816f030c2015ffff ...

Страница 900: ...y support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2017ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 23 This message is for the use case when an implementation has detected a Memory Scrub failure recovery May also be shown as 816f030c2017ffff or 0x816f...

Страница 901: ...Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2581ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered All DIMMS This message is for the use case when an implementation has detected a Memory Scrub failure recovery May also be shown as 816f030c2581ffff or 0x816f030c2581ffff Seve...

Страница 902: ... Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 0401ffff Hot spare disabled for ComputerSystemElementName Drive 1 This message is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d0401ffff or 0x816f030d0401ffff Severity Info Serviceable No Automatically notify support No Alert Ca...

Страница 903: ...nse No action information only 816f030d 0403ffff Hot spare disabled for ComputerSystemElementName Drive 3 This message is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d0403ffff or 0x816f030d0403ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 01...

Страница 904: ... is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d0405ffff or 0x816f030d0405ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 0406ffff Hot spare disabled for ComputerSystemElementName Drive 6...

Страница 905: ...ed May also be shown as 816f030d0407ffff or 0x816f030d0407ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 0408ffff Hot spare disabled for ComputerSystemElementName Drive 8 This message is for the use case when an implementation has detected a Hot Spare ha...

Страница 906: ...e shown as 816f030d0409ffff or 0x816f030d0409ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 040affff Hot spare disabled for ComputerSystemElementName Drive 10 This message is for the use case when an implementation has detected a Hot Spare has been Disab...

Страница 907: ...fff or 0x816f030d040bffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 040cffff Hot spare disabled for ComputerSystemElementName Drive 12 This message is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as...

Страница 908: ... Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 040effff Hot spare disabled for ComputerSystemElementName Drive 14 This message is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d040effff or 0x81...

Страница 909: ...able No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 0410ffff Hot spare disabled for ComputerSystemElementName Drive 16 This message is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d0410ffff or 0x816f030d0410ffff Severit...

Страница 910: ... notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 0412ffff Hot spare disabled for ComputerSystemElementName Drive 18 This message is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d0412ffff or 0x816f030d0412ffff Severity Info Serviceable No...

Страница 911: ...Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 0414ffff Hot spare disabled for ComputerSystemElementName Drive 20 This message is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d0414ffff or 0x816f030d0414ffff Severity Info Serviceable No Automatically notify sup...

Страница 912: ... ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 0416ffff Hot spare disabled for ComputerSystemElementName Drive 22 This message is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d0416ffff or 0x816f030d0416ffff Severity Info Serviceable No Automatically notify support No Alert Category System O...

Страница 913: ...se No action information only 816f030d 0418ffff Hot spare disabled for ComputerSystemElementName Drive 24 This message is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d0418ffff or 0x816f030d0418ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 01...

Страница 914: ... is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d041affff or 0x816f030d041affff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 041bffff Hot spare disabled for ComputerSystemElementName Drive 2...

Страница 915: ...ed May also be shown as 816f030d041cffff or 0x816f030d041cffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 041dffff Hot spare disabled for ComputerSystemElementName Drive 29 This message is for the use case when an implementation has detected a Hot Spare h...

Страница 916: ...e shown as 816f030d041effff or 0x816f030d041effff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 041fffff Hot spare disabled for ComputerSystemElementName Drive 31 This message is for the use case when an implementation has detected a Hot Spare has been Disab...

Страница 917: ...0420ffff or 0x816f030d0420ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f0313 1701ffff System ComputerSystemElementName has recovered from an NMI NMI State This message is for the use case when an implementation has detected a Software NMI has been Recovered ...

Страница 918: ...ffff or 0x816f040c2001ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2002ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 2 This message is for the use case when an implementation has detected that Memory has been Enabled May al...

Страница 919: ...003ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2004ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 4 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f...

Страница 920: ...everity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2006ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 6 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2006f...

Страница 921: ...erviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2008ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 8 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2008ffff or 0x816f0...

Страница 922: ... Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 200affff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 10 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c200affff or 0x816f040c200affff ...

Страница 923: ...atically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 200cffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 12 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c200cffff or 0x816f040c200cffff Severi...

Страница 924: ... notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 200effff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 14 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c200effff or 0x816f040c200effff Severity Info ...

Страница 925: ... Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2010ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 16 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2010ffff or 0x816f040c2010ffff Severity Info Serviceable No Aut...

Страница 926: ...ystem Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2012ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 18 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2012ffff or 0x816f040c2012ffff Severity Info Serviceable No Automatically notify...

Страница 927: ... ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2014ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 20 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2014ffff or 0x816f040c2014ffff Severity Info Serviceable No Automatically notify support No Alert Cat...

Страница 928: ...mation Prefix PLAT ID 0130 User Response No action information only 816f040c 2016ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 22 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2016ffff or 0x816f040c2016ffff Severity Info Serviceable No Automatically notify support No Alert Category System ...

Страница 929: ...mation Prefix PLAT ID 0130 User Response No action information only 816f040c 2018ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 24 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2018ffff or 0x816f040c2018ffff Severity Info Serviceable No Automatically notify support No Alert Category System ...

Страница 930: ... Prefix PLAT ID 0130 User Response No action information only One of the DIMMs 816f0413 2582ffff A PCI PERR recovery has occurred on system ComputerSystemElementName PCIs This message is for the use case when an implementation has detected a PCI PERR recovered May also be shown as 816f04132582ffff or 0x816f04132582ffff Severity Info Serviceable No Automatically notify support No Alert Category Cri...

Страница 931: ...mation Prefix PLAT ID 0063 User Response No action information only 816f0507 0302ffff ProcessorElementName has Recovered from a Configuration Mismatch CPU 2 This message is for the use case when an implementation has Recovered from a Processor Configuration Mismatch May also be shown as 816f05070302ffff or 0x816f05070302ffff Severity Info Serviceable No Automatically notify support No Alert Catego...

Страница 932: ...063 User Response No action information only One of the CPUs 816f050c 2001ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 1 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2001ffff or 0x816f050c2001ffff Severity Info Serviceable No Automatically notif...

Страница 933: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 2003ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 3 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2003ffff or 0x816f050c2003ffff Severity Info Serviceable No Automaticall...

Страница 934: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 2005ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 5 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2005ffff or 0x816f050c2005ffff Severity Info Serviceable No Automaticall...

Страница 935: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 2007ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 7 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2007ffff or 0x816f050c2007ffff Severity Info Serviceable No Automaticall...

Страница 936: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 2009ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 9 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2009ffff or 0x816f050c2009ffff Severity Info Serviceable No Automaticall...

Страница 937: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 200bffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 11 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c200bffff or 0x816f050c200bffff Severity Info Serviceable No Automatical...

Страница 938: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 200dffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 13 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c200dffff or 0x816f050c200dffff Severity Info Serviceable No Automatical...

Страница 939: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 200fffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 15 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c200fffff or 0x816f050c200fffff Severity Info Serviceable No Automatical...

Страница 940: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 2011ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 17 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2011ffff or 0x816f050c2011ffff Severity Info Serviceable No Automatical...

Страница 941: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 2013ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 19 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2013ffff or 0x816f050c2013ffff Severity Info Serviceable No Automatical...

Страница 942: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 2015ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 21 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2015ffff or 0x816f050c2015ffff Severity Info Serviceable No Automatical...

Страница 943: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 2017ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 23 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2017ffff or 0x816f050c2017ffff Severity Info Serviceable No Automatical...

Страница 944: ...efix PLAT ID 0145 User Response No action information only 816f050c 2581ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName All DIMMS This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2581ffff or 0x816f050c2581ffff Severity Info Serviceable No Automatically noti...

Страница 945: ...mation Prefix PLAT ID 0175 User Response No action information only 816f050d 0401ffff Critical Array ComputerSystemElementName has deasserted Drive 1 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0401ffff or 0x816f050d0401ffff Severity Info Serviceable No Automatically notify support No Alert Category Critic...

Страница 946: ...No action information only 816f050d 0403ffff Critical Array ComputerSystemElementName has deasserted Drive 3 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0403ffff or 0x816f050d0403ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Inf...

Страница 947: ...fff Critical Array ComputerSystemElementName has deasserted Drive 5 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0405ffff or 0x816f050d0405ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 948: ...fff Critical Array ComputerSystemElementName has deasserted Drive 7 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0407ffff or 0x816f050d0407ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 949: ...ff Critical Array ComputerSystemElementName has deasserted Drive 9 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0409ffff or 0x816f050d0409ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response...

Страница 950: ...ff Critical Array ComputerSystemElementName has deasserted Drive 11 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d040bffff or 0x816f050d040bffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 951: ...ff Critical Array ComputerSystemElementName has deasserted Drive 13 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d040dffff or 0x816f050d040dffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 952: ...ff Critical Array ComputerSystemElementName has deasserted Drive 15 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d040fffff or 0x816f050d040fffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 953: ...ff Critical Array ComputerSystemElementName has deasserted Drive 17 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0411ffff or 0x816f050d0411ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 954: ...ff Critical Array ComputerSystemElementName has deasserted Drive 19 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0413ffff or 0x816f050d0413ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 955: ...ff Critical Array ComputerSystemElementName has deasserted Drive 21 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0415ffff or 0x816f050d0415ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 956: ...ff Critical Array ComputerSystemElementName has deasserted Drive 23 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0417ffff or 0x816f050d0417ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 957: ...ff Critical Array ComputerSystemElementName has deasserted Drive 25 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0419ffff or 0x816f050d0419ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 958: ...ff Critical Array ComputerSystemElementName has deasserted Drive 27 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d041bffff or 0x816f050d041bffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 959: ...ff Critical Array ComputerSystemElementName has deasserted Drive 29 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d041dffff or 0x816f050d041dffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 960: ...f Critical Array ComputerSystemElementName has deasserted Drive 31 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d041fffff or 0x816f050d041fffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response...

Страница 961: ... has deasserted PCIs This message is for the use case when an implementation has detected a PCI SERR deassertion May also be shown as 816f05132582ffff or 0x816f05132582ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0235 User Response No action information only 816f0607 0301ffff An SM BIOS Uncorrectable ...

Страница 962: ...le CPU complex error has deasserted May also be shown as 816f06070302ffff or 0x816f06070302ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0817 User Response No action information only 816f0607 2584ffff An SM BIOS Uncorrectable CPU complex error for ProcessorElementName has deasserted All CPUs This message...

Страница 963: ...is OK May also be shown as 816f06081301ffff or 0x816f06081301ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0105 User Response No action information only 816f060d 0400ffff Array in system ComputerSystemElementName has been restored Drive 0 This message is for the use case when an implementation has detec...

Страница 964: ...ed May also be shown as 816f060d0401ffff or 0x816f060d0401ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0402ffff Array in system ComputerSystemElementName has been restored Drive 2 This message is for the use case when an implementation ha...

Страница 965: ...also be shown as 816f060d0403ffff or 0x816f060d0403ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0404ffff Array in system ComputerSystemElementName has been restored Drive 4 This message is for the use case when an implementation has detec...

Страница 966: ...shown as 816f060d0405ffff or 0x816f060d0405ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0406ffff Array in system ComputerSystemElementName has been restored Drive 6 This message is for the use case when an implementation has detected that...

Страница 967: ... 816f060d0407ffff or 0x816f060d0407ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0408ffff Array in system ComputerSystemElementName has been restored Drive 8 This message is for the use case when an implementation has detected that a Faile...

Страница 968: ...f or 0x816f060d0409ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 040affff Array in system ComputerSystemElementName has been restored Drive 10 This message is for the use case when an implementation has detected that a Failed Array has bee...

Страница 969: ...40bffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 040cffff Array in system ComputerSystemElementName has been restored Drive 12 This message is for the use case when an implementation has detected that a Failed Array has been Restored May a...

Страница 970: ...everity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 040effff Array in system ComputerSystemElementName has been restored Drive 14 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be sh...

Страница 971: ...able No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0410ffff Array in system ComputerSystemElementName has been restored Drive 16 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0410f...

Страница 972: ...ly notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0412ffff Array in system ComputerSystemElementName has been restored Drive 18 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0412ffff or 0x816f060d04...

Страница 973: ...fy support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0414ffff Array in system ComputerSystemElementName has been restored Drive 20 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0414ffff or 0x816f060d0414ffff ...

Страница 974: ...t No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0416ffff Array in system ComputerSystemElementName has been restored Drive 22 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0416ffff or 0x816f060d0416ffff Severity ...

Страница 975: ...y Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0418ffff Array in system ComputerSystemElementName has been restored Drive 24 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0418ffff or 0x816f060d0418ffff Severity Info Serviceable N...

Страница 976: ...isk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 041affff Array in system ComputerSystemElementName has been restored Drive 26 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d041affff or 0x816f060d041affff Severity Info Serviceable No Automatically n...

Страница 977: ...D 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 041cffff Array in system ComputerSystemElementName has been restored Drive 28 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d041cffff or 0x816f060d041cffff Severity Info Serviceable No Automatically notify support No Aler...

Страница 978: ...mation Prefix PLAT ID 0177 User Response No action information only 816f060d 041effff Array in system ComputerSystemElementName has been restored Drive 30 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d041effff or 0x816f060d041effff Severity Info Serviceable No Automatically notify support No Alert Category Cr...

Страница 979: ...mation Prefix PLAT ID 0177 User Response No action information only 816f060d 0420ffff Array in system ComputerSystemElementName has been restored Ext Drive This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0420ffff or 0x816f060d0420ffff Severity Info Serviceable No Automatically notify support No Alert Category C...

Страница 980: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2002ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 2 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2002ffff or 0x816f070c2002ffff Severity Info Serviceable No Auto...

Страница 981: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2004ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 4 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2004ffff or 0x816f070c2004ffff Severity Info Serviceable No Auto...

Страница 982: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2006ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 6 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2006ffff or 0x816f070c2006ffff Severity Info Serviceable No Auto...

Страница 983: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2008ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 8 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2008ffff or 0x816f070c2008ffff Severity Info Serviceable No Auto...

Страница 984: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 200affff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 10 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c200affff or 0x816f070c200affff Severity Info Serviceable No Aut...

Страница 985: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 200cffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 12 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c200cffff or 0x816f070c200cffff Severity Info Serviceable No Aut...

Страница 986: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 200effff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 14 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c200effff or 0x816f070c200effff Severity Info Serviceable No Aut...

Страница 987: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2010ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 16 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2010ffff or 0x816f070c2010ffff Severity Info Serviceable No Aut...

Страница 988: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2012ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 18 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2012ffff or 0x816f070c2012ffff Severity Info Serviceable No Aut...

Страница 989: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2014ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 20 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2014ffff or 0x816f070c2014ffff Severity Info Serviceable No Aut...

Страница 990: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2016ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 22 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2016ffff or 0x816f070c2016ffff Severity Info Serviceable No Aut...

Страница 991: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2018ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 24 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2018ffff or 0x816f070c2018ffff Severity Info Serviceable No Aut...

Страница 992: ...ap ID 41 CIM Information Prefix PLAT ID 0127 User Response No action information only One of the DIMMs 816f070d 0400ffff Rebuild completed for Array in system ComputerSystemElementName Drive 0 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0400ffff or 0x816f070d0400ffff Severity Info Serviceable No Automatically...

Страница 993: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0402ffff Rebuild completed for Array in system ComputerSystemElementName Drive 2 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0402ffff or 0x816f070d0402ffff Severity Info Serviceable No Automatically notify support No Alert Category S...

Страница 994: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0404ffff Rebuild completed for Array in system ComputerSystemElementName Drive 4 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0404ffff or 0x816f070d0404ffff Severity Info Serviceable No Automatically notify support No Alert Category S...

Страница 995: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0406ffff Rebuild completed for Array in system ComputerSystemElementName Drive 6 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0406ffff or 0x816f070d0406ffff Severity Info Serviceable No Automatically notify support No Alert Category S...

Страница 996: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0408ffff Rebuild completed for Array in system ComputerSystemElementName Drive 8 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0408ffff or 0x816f070d0408ffff Severity Info Serviceable No Automatically notify support No Alert Category S...

Страница 997: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 040affff Rebuild completed for Array in system ComputerSystemElementName Drive 10 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d040affff or 0x816f070d040affff Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 998: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 040cffff Rebuild completed for Array in system ComputerSystemElementName Drive 12 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d040cffff or 0x816f070d040cffff Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 999: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 040effff Rebuild completed for Array in system ComputerSystemElementName Drive 14 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d040effff or 0x816f070d040effff Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 1000: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0410ffff Rebuild completed for Array in system ComputerSystemElementName Drive 16 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0410ffff or 0x816f070d0410ffff Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 1001: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0412ffff Rebuild completed for Array in system ComputerSystemElementName Drive 18 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0412ffff or 0x816f070d0412ffff Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 1002: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0414ffff Rebuild completed for Array in system ComputerSystemElementName Drive 20 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0414ffff or 0x816f070d0414ffff Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 1003: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0416ffff Rebuild completed for Array in system ComputerSystemElementName Drive 22 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0416ffff or 0x816f070d0416ffff Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 1004: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0418ffff Rebuild completed for Array in system ComputerSystemElementName Drive 24 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0418ffff or 0x816f070d0418ffff Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 1005: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 041affff Rebuild completed for Array in system ComputerSystemElementName Drive 26 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d041affff or 0x816f070d041affff Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 1006: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 041cffff Rebuild completed for Array in system ComputerSystemElementName Drive 28 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d041cffff or 0x816f070d041cffff Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 1007: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 041effff Rebuild completed for Array in system ComputerSystemElementName Drive 30 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d041effff or 0x816f070d041effff Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 1008: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0420ffff Rebuild completed for Array in system ComputerSystemElementName Ext Drive This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0420ffff or 0x816f070d0420ffff Severity Info Serviceable No Automatically notify support No Alert Category...

Страница 1009: ...Response No action information only 816f0807 0302ffff ProcessorElementName has been Enabled CPU 2 This message is for the use case when an implementation has detected a Processor has been Enabled May also be shown as 816f08070302ffff or 0x816f08070302ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0060 User R...

Страница 1010: ...tName has recovered from an Uncorrectable Bus Error DIMMs This message is for the use case when an implementation has detected a that a system has recovered from a Bus Uncorrectable Error May also be shown as 816f08132581ffff or 0x816f08132581ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0241 User Resp...

Страница 1011: ...information only 816f0813 2584ffff System ComputerSystemElementName has recovered from an Uncorrectable Bus Error CPUs This message is for the use case when an implementation has detected a that a system has recovered from a Bus Uncorrectable Error May also be shown as 816f08132584ffff or 0x816f08132584ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other ...

Страница 1012: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2002ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 2 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2002ffff or 0x816f090c2002ffff Severity Info Serviceable No Automatically notify support No Alert C...

Страница 1013: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2004ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 4 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2004ffff or 0x816f090c2004ffff Severity Info Serviceable No Automatically notify support No Alert C...

Страница 1014: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2006ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 6 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2006ffff or 0x816f090c2006ffff Severity Info Serviceable No Automatically notify support No Alert C...

Страница 1015: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2008ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 8 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2008ffff or 0x816f090c2008ffff Severity Info Serviceable No Automatically notify support No Alert C...

Страница 1016: ...ation Prefix PLAT ID 0143 User Response No action information only 816f090c 200affff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 10 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c200affff or 0x816f090c200affff Severity Info Serviceable No Automatically notify support No Alert C...

Страница 1017: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 200cffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 12 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c200cffff or 0x816f090c200cffff Severity Info Serviceable No Automatically notify support No Alert ...

Страница 1018: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 200effff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 14 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c200effff or 0x816f090c200effff Severity Info Serviceable No Automatically notify support No Alert ...

Страница 1019: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2010ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 16 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2010ffff or 0x816f090c2010ffff Severity Info Serviceable No Automatically notify support No Alert ...

Страница 1020: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2012ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 18 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2012ffff or 0x816f090c2012ffff Severity Info Serviceable No Automatically notify support No Alert ...

Страница 1021: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2014ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 20 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2014ffff or 0x816f090c2014ffff Severity Info Serviceable No Automatically notify support No Alert ...

Страница 1022: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2016ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 22 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2016ffff or 0x816f090c2016ffff Severity Info Serviceable No Automatically notify support No Alert ...

Страница 1023: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2018ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 24 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2018ffff or 0x816f090c2018ffff Severity Info Serviceable No Automatically notify support No Alert ...

Страница 1024: ...mation Prefix PLAT ID 0039 User Response No action information only 816f0a07 0302ffff The Processor ProcessorElementName is no longer operating in a Degraded State CPU 2 This message is for the use case when an implementation has detected a Processor is no longer running in the Degraded state May also be shown as 816f0a070302ffff or 0x816f0a070302ffff Severity Info Serviceable No Automatically not...

Страница 1025: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2002ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 2 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2002ffff or 0x816f0a0c2002ffff Seve...

Страница 1026: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2004ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 4 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2004ffff or 0x816f0a0c2004ffff Seve...

Страница 1027: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2006ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 6 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2006ffff or 0x816f0a0c2006ffff Seve...

Страница 1028: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2008ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 8 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2008ffff or 0x816f0a0c2008ffff Seve...

Страница 1029: ...ation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 200affff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 10 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c200affff or 0x816f0a0c200affff Seve...

Страница 1030: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 200cffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 12 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c200cffff or 0x816f0a0c200cffff Sev...

Страница 1031: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 200effff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 14 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c200effff or 0x816f0a0c200effff Sev...

Страница 1032: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2010ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 16 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2010ffff or 0x816f0a0c2010ffff Sev...

Страница 1033: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2012ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 18 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2012ffff or 0x816f0a0c2012ffff Sev...

Страница 1034: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2014ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 20 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2014ffff or 0x816f0a0c2014ffff Sev...

Страница 1035: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2016ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 22 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2016ffff or 0x816f0a0c2016ffff Sev...

Страница 1036: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2018ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 24 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2018ffff or 0x816f0a0c2018ffff Sev...

Страница 1037: ...ink and Replacing a microprocessor and heat sink 2 If the problem persists and there is no other CPU with the same error indication replace the system board 3 Trained technician only Replace the system board see Removing the system board and Replacing the system board n microprocessor number 816f0a13 0302ffff System ComputerSystemElementName has recovered from a Fatal Bus Error CPU 2 PECI This mes...

Страница 1038: ...nk and Replacing a microprocessor and heat sink 2 If the problem persists and there is no other CPU with the same error indication replace the system board 3 Trained technician only Replace the system board see Removing the system board and Replacing the system board n microprocessor number 1026 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 1039: ...A warning is not as severe as an error but if possible the condition should be corrected before it becomes an error It might also be a condition that requires additional monitoring or maintenance Error An error typically indicates a failure or critical condition that impairs service or an expected function User response The actions that you should take to resolve the event Perform the steps in the...

Страница 1040: ...sists ensure that matching processors are installed i e matching option part numbers etc 3 Verify that the Processor s are installed in the correct sockets according to the service information for this product If not correct that problem 4 Check IBM support site for an applicable service bulletin or UEFI firmware update that applies to this processor error 5 Trained Service technician only Replace...

Страница 1041: ...ors have one or more cache levels with mismatched associativity Explanation Severity Error User Response Complete the following steps 1 Verify that matching processors are installed in the correct processor sockets Correct any mismatch found 2 Check the IBM support site for an applicable service bulletin or firmware update that applies to this processor error 3 Trained technician only Replace the ...

Страница 1042: ...an applicable service bulletin or firmware update that applies to this processor error 3 Trained technician only Replace the system board I 2018002 The device found at Bus arg1 Device arg2 Function arg3 could not be configured due to resource constraints The Vendor ID for the device is arg4 and the Device ID is arg5 OUT_OF_RESOURCES PCI Option ROM Explanation Severity Info User Response Complete t...

Страница 1043: ...TE It may be necessary to configure slot to Gen1 or to use special utility software so that adapter firmware can be upgraded Gen1 Gen2 settings can be configured via F1 Setup System Settings Devices and I O Ports PCIe Gen1 Gen2 Gen3 Speed Selection or the ToolsCenter Suite CLI Utility 4 Replace the adapter I 3808004 The IMM System Event log SEL is full IPMI System Event Log is Full Explanation Sev...

Страница 1044: ...e following steps 1 If system failed to boot successfully DC cycle the system 2 If system boots to F1 setup update the UEFI image and reset bank to primary if required If the system boots without error recovery is complete and no additional action is required 3 If system fails to boot or if the firmware update attempt fails trained service technician only replace the system board I 3818009 The TPM...

Страница 1045: ...ied DIMM Serial Number Detected Explanation Severity Info User Response Complete the following steps 1 If this information event is logged in the IMM event log the server does not have qualified memory installed 2 The memory installed may not be covered under warranty 3 Without qualified memory speeds supported above industry standards will not be enabled 4 Please contact your Local Sales Represen...

Страница 1046: ... Detected Explanation Severity Info User Response Complete the following steps 1 Check the system event log for uncorrected DIMM failures and replace those DIMMs I 580A6 Memory spare copy has completed successfully Spare Copy Complete Explanation Severity Info User Response Complete the following steps 1 If you have added or removed DIMMs to the system and no additional errors were detected then p...

Страница 1047: ...vice technician only Inspect Processor socket on each Processor removal and replace system board first if damaged or mis aligned pins are found Replace the system board S 2011001 An Uncorrected PCIe Error has Occurred at Bus arg1 Device arg2 Function arg3 The Vendor ID for the device is arg4 and the Device ID is arg5 PCI SERR Detected Explanation Severity Error User Response Complete the following...

Страница 1048: ... Gen1 Gen2 Gen3 Speed Selection or the ToolsCenter Suite CLI Utility 3 If problem persists then remove Adapter Card If system reboots successfully without the adapter replace that card 4 Trained Service technician only Replace the system board 5 Trained Service technician only Replace the processor S 3020007 A firmware fault has been detected in the UEFI image Internal UEFI Firmware Fault Detected...

Страница 1049: ... steps 1 Check IBM support site for an applicable service bulletin or firmware update that applies to this error 2 Update the UEFI image 3 Replace the system board S 3050007 A firmware fault has been detected in the UEFI image Internal UEFI Firmware Fault Detected System halted Explanation Severity Error User Response Complete the following steps 1 Check IBM support site for an applicable service ...

Страница 1050: ...EFI firmware 6 Remove and re install CMOS battery for 30 seconds to clear CMOS contents 7 Trained service technician only Replace the system board S 3060007 A firmware fault has been detected in the UEFI image Internal UEFI Firmware Fault Detected System halted Explanation Severity Error User Response Complete the following steps 1 Check IBM support site for an applicable service bulletin or firmw...

Страница 1051: ...chnician only Replace the system board S 3818007 The firmware image capsules for both flash banks could not be verified CRTM image capsule could not be verified Explanation Severity Error User Response Complete the following steps 1 If system failed to boot successfully DC cycle system 2 If system boots to F1 setup update the UEFI image and reset bank to primary if required If the system boots wit...

Страница 1052: ...inspect Processor socket pins for damaged or mis aligned pins If damage is found or this is an upgrade Processor replace the system board If there are multiple Processor s swap Processor s to move affected Processor to another Processor socket and retry If problem follows the affected Processor or there is only one Processor replace the affected Processor 6 Trained technician only If problem stays...

Страница 1053: ...k to ensure that DIMMs are firmly seated and that no foreign material can be seen in the DIMM connector If either condition is observed correct and retry with the same DIMM Note The event Log might contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 If problem persists replace the DIMM identified by LightPath and or event log entry 4 I...

Страница 1054: ...r Response Complete the following steps 1 Check the IBM support site for an applicable service bulletin or firmware update that applies to this error 2 Inspect the processor socket for foreign debris or damage If debris is found remove the debris 3 Trained technician only If error recurs or socket damage is found replace the system board 4 Trained Service Technician Only Replace the processor S 68...

Страница 1055: ...ent Automated Boot Recovery Booting Backup UEFI Image Explanation Severity Warning User Response Complete the following steps 1 Check the IBM support site for an applicable service bulletin or firmware update that applies to this error 2 Update the primary UEFI image 3 Replace the system board W 305000A An invalid date and time have been detected RTC Date and Time Incorrect Explanation Severity Wa...

Страница 1056: ...m persists switch to backup UEFI or update the current UEFI image 3 Replace the system board W 305800B DRIVER HEALTH PROTOCOL Reports Reboot Required Controller DRIVER HEALTH PROTOCOL Reports Reboot Required Controller Explanation Severity Warning User Response Complete the following steps 1 No action required The system will reboot at the end of POST 2 If the problem persists switch to the backup...

Страница 1057: ...tatus Driver DRIVER HEALTH PROTOCOL Reports Invalid Health Status Driver Explanation Severity Warning User Response Complete the following steps 1 No action required The system will reboot at the end of POST 2 If the problem persists switch to the backup UEFI image or update the current UEFI image 3 Replace the system board W 3808000 An IMM communication failure has occurred IMM Communication Fail...

Страница 1058: ... Retrieving System Configuration from IMM Explanation Severity Warning User Response Complete the following steps 1 Use the Setup Utility to verify and save the settings which will recover the settings 2 Reset the IMM from the CMM 3 Use CMM to remove auxiliary power from the compute node This will reboot the compute node 4 Check the IBM support site for an applicable service bulletin or firmware u...

Страница 1059: ...support W 3868002 IFM Error communicating with the IMM IFM may not be deployed correctly IFM Error communicating with the IMM IFM may not be deployed correctly Explanation Severity Error User Response Complete the following steps 1 Update all firmware including adapter firmware to the latest levels 2 If problem persists escalate to the next level of support W 3938002 A boot configuration error has...

Страница 1060: ...st the known problems the update addresses 3 If the previous steps do not resolve the problem at the next maintenance opportunity swap the DIMMs on the same memory channel one at a time to a different memory channel or Processor check service information for this product Install guide for population requirements for sparing paring modes If PFA follows a moved DIMM to any DIMM connector on the diff...

Страница 1061: ...e Explanation Severity Error User Response Complete the following steps 1 If a DIMM connector error LED is lit resolve the failure 2 Make sure that the DIMM connectors are correctly populated for mirroring mode W 580A2 Invalid memory configuration for Sparing Mode Please correct memory configuration Unsupported DIMM Population for Spare Mode Explanation Severity Error User Response Complete the fo...

Страница 1062: ...ry is properly seated 2 Check the IBM support site for an applicable service bulletin or firmware update that applies to this error 3 Replace the CMOS battery 4 Trained technician only Replace the system board 1050 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 1063: ...result when you run the DSA Broadcom network test 405 000 000 BRCM TestControlRegisters Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 001 000 BRCM TestMIIRegisters Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify s...

Страница 1064: ...003 000 BRCM TestInternalMemory Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 004 000 BRCM TestInterrupt Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No 1052 HX3510 G HX5510 HX5510 C HX7510 Installation...

Страница 1065: ...No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 006 000 BRCM TestLoopbackPhysical Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 007 000 BRCM TestLEDs Test Passed The test passed Recoverable No Appendix C DSA diagnostic tes...

Страница 1066: ...Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 801 000 BRCM TestMIIRegisters Test Aborted The MII register test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 1054 HX3510 G HX551...

Страница 1067: ...3 000 BRCM TestInternalMemory Test Aborted The internal memory test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 804 000 BRCM TestInterrupt Test Aborted The interrupt test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Appendi...

Страница 1068: ...t website Latest level of DSA Latest level of BMC IMM 405 806 000 BRCM TestLoopbackPhysical Test Aborted Loopback testing at the physical layer was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 807 000 BRCM TestLEDs Test Aborted Verification of status LEDs was canceled Recove...

Страница 1069: ...t firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 9...

Страница 1070: ...ile testing non volatile RAM Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting by s...

Страница 1071: ...TestInterrupt Test Failed A failure was detected while testing interrupts Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If ...

Страница 1072: ...MC IMM 405 906 000 BRCM TestLoopbackPhysical Test Failed A failure was detected during the loopback test at the physical layer Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware ...

Страница 1073: ...mponent 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA Brocade test results The following messages can result when you run the Brocade test Test results for the DSA Brocade test The following messages can result whe...

Страница 1074: ...links IBM Support website Latest level of DSA Latest level of BMC IMM 218 002 000 Brocade SerdesLoopbackTest Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 003 000 Brocade PCILoopbackTest Passed The test passed Recoverable No 1062 HX3510 G HX5510 HX5510 C HX7510 In...

Страница 1075: ...erable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 005 000 Brocade SerdesEthLoopbackTest Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM Appendix C DSA diagnostic test...

Страница 1076: ... 000 Brocade MemoryTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 801 000 Brocade ExternalLoopbackTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No 1064 HX3510 G HX5510 HX5510 C HX7510 In...

Страница 1077: ...ated links IBM Support website Latest level of DSA Latest level of BMC IMM 218 803 000 Brocade PCILoopbackTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 804 000 Brocade ExternalEthLoopbackTest Aborted The test was canceled Recoverable No Appendix C DS...

Страница 1078: ...erity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 806 000 Brocade InternalLoopbackTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 1066 HX3510 G HX5510 HX5510 C HX7...

Страница 1079: ...port representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 901 000 Brocade ExternalLoopbackTest Failed A failure was detected during the Loopback test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check cable connections 2 Rerun the test 3 Verify whether the firmware is at proper...

Страница 1080: ...lem remains contact your IBM technical support representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 903 000 Brocade PCILoopbackTest Failed A failure was detected during the Loopback test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Rerun the test 2 Verify whether the firmware i...

Страница 1081: ... cable 2 Rerun the test 3 Verify whether the firmware is at proper level 4 Rerun the test 5 If the problem remains contact your IBM technical support representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 905 000 Brocade SerdesEthLoopbackTest Failed A failure was detected during the Loopback test Recoverable No Severity Error Serviceable Yes Automatically ...

Страница 1082: ...following steps 1 Rerun the test 2 Verify whether the firmware is at proper level 3 Rerun the test 4 If the problem remains contact your IBM technical support representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA checkpoint panel test results The following messages can result when you run the checkpoint panel test Test results for the DSA checkpoint panel...

Страница 1083: ... No User Response Complete the following steps 1 Inspect and reseat operator information panel cable at both ends 2 Verify that the Baseboard Management Controller BMC is working 3 Run the test again 4 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level ...

Страница 1084: ...m in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA CPU stress test results The following messages can result when you run the CPU stress test Test results for the DSA CPU stress test The following messages can result when you run the DSA CPU stress test 089 000 000 CPU Stress Test Passed CP...

Страница 1085: ...tion for this component The latest level firmware for this component can be found in reference to this system type at the IBM Support website 5 Run the test again 6 If the system has stopped responding turn off and restart the system and then run the test again 7 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Relat...

Страница 1086: ...hooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 089 803 000 CPU Stress Test Aborted CPU Stress Test Aborted Memory size is insufficient to run the test At least 1GB is required Recoverable No Severity Warning Serviceable Yes Automatically notify support No Related links IBM ...

Страница 1087: ...found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 5 Run the test again 6 If the system has stopped responding turn off and restart the system and then run the test again 7 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Late...

Страница 1088: ...st Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 516 002 000 ELXUCNA ELXUCNA NIC LED Beacon Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links 1076 HX3510 G HX5510 HX5510 C HX7510 Installation and Ser...

Страница 1089: ... Latest level of DSA Latest level of BMC IMM 516 801 000 ELXUCNA NIC PHY LoopBackTest Aborted Loopback testing at the physical layer was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 516 802 000 ELXUCNA ELXUCNA NIC LED Beacon Test Aborted Verification of status LEDs was canceled ...

Страница 1090: ... The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 516 901 000 ELXUCNA NIC PHY LoopBackTest Faile...

Страница 1091: ...ble No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and...

Страница 1092: ...support No User Response Complete the following steps 1 Remove power cables wait for 45 seconds reconnect and rerun the test 2 Make sure that the scalability cable connections are as per specification 3 Make sure that DSA and BIOS uEFI are at the latest level 4 If the problem remains contact your technical service representative Related links IBM Support website Latest level of DSA Latest level of...

Страница 1093: ...st level of BMC IMM 401 901 001 EXA Port Ping Test Failed EXA Port Ping Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Remove power cables wait for 45 seconds reconnect and rerun the test 2 Make sure that the scalability cable connections are as per specification 3 Check scalability cables for loose connections...

Страница 1094: ...No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 217 800 000 HDD Test Aborted HDD Test Aborted The test was canceled Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check cable connections 2 Rerun the test 3 Verify that Hard drive supports self test and self test logging 4 If the problem re...

Страница 1095: ...e is at the latest level 4 Rerun the test 5 If the problem remains contact your technical support representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA Intel network test results The following messages can result when you run the Intel network test Test results for the DSA Intel network test The following messages can result when you run the DSA Intel net...

Страница 1096: ...Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 406 002 000 IANet FIFO Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 406 003 000 IANet Interrupts Test Passed 1084 HX3510 G HX5510 HX5510 C HX7510 Instal...

Страница 1097: ...pback Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 406 800 000 IANet Registers Test Aborted Registers test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Appendix C DSA diagnostic test results 1085 ...

Страница 1098: ...ebsite Latest level of DSA Latest level of BMC IMM 406 802 000 IANet FIFO Test Aborted FIFO test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 406 803 000 IANet Interrupts Test Aborted Interrupt test was canceled Recoverable No Severity Warning 1086 HX3510 G HX5510 HX5510 C H...

Страница 1099: ...Registers Test Failed A failure was detected during the Registers test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If fai...

Страница 1100: ...n the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 406 902 000 IANet FIFO Test Failed A failure was detected during the FIFO test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complet...

Страница 1101: ...und in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 Check interrupt assignments in the PCI Hardware section of the DSA Diagnostic Log If the ethernet device is sharing interrupts if possible modify the interrupt assignments using F1 Setup to assign a unique interrupt to the device 4 Rerun the test 5 If failure remains refer to Troubleshooting b...

Страница 1102: ...e next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA LSI hard drive test results The following messages can result when you run the LSI hard drive test Test results for the DSA LSI hard drive test The following messages can result when you run the DSA LSI hard drive test 407 000 000 LSIESG DiskDefaultDiagnostic Test Passed The test passed Recov...

Страница 1103: ...Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check cable connections 2 Rerun the test 3 Verify whether the firmware is at the latest level 4 Rerun the test 5 If the problem remains contact your IBM technical support representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA Mellanox adapter test results The follo...

Страница 1104: ...nks IBM Support website Latest level of DSA Latest level of BMC IMM 408 001 000 MLNX MLNX_DiagnosticTestIBPort Test Passed Port Test Passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 408 800 000 MLNX MLNX_DiagnosticTestEthernetPort Test Aborted Port Test was canceled Recoverable No Sever...

Страница 1105: ...SA Latest level of BMC IMM 408 900 000 MLNX MLNX_DiagnosticTestEthernetPort Test Failed Port Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Make sure that the physical link of the port under test in the active state 2 If these condition was met but the test keeps failing the port s adapter might be faulty 3 Try...

Страница 1106: ...t but the test keeps failing the port s adapter might be faulty 3 Try replacing the adapter and repeating the test Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA memory isolation test results The following messages can result when you run the memory isolation test Test results for the DSA memory isolation test The following messages can result when you run the DS...

Страница 1107: ...otify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 000 002 Standalone Memory Test Passed Quick Full Memory Test CPU 2 Passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 000 003 Standalone Memory Test Passed Quick Full Memory Test CPU 3 P...

Страница 1108: ...viceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 811 000 Standalone Memory Test Aborted Unable to Locate SMBIOS key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action...

Страница 1109: ... notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Su...

Страница 1110: ...S key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make s...

Страница 1111: ...e Memory Test Aborted Memory test is not supported for this system Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for...

Страница 1112: ...atest level of BMC IMM 201 812 003 Standalone Memory Test Aborted Memory test is not supported for this system Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the ...

Страница 1113: ...BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 813 001 Standalone Memory Test Aborted Chipset Error Can not turn OFF ECC error reporting in CPU Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test af...

Страница 1114: ...and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 813 003 Standalone Memory Test Aborted Chipset Error Can not turn OFF ECC error reporting in CPU Recoverable No Severity Warning Serviceable No Automatically notify support N...

Страница 1115: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Lat...

Страница 1116: ...ure for CPU Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make ...

Страница 1117: ... Aborted Program Error with Quick Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1118: ...t level of BMC IMM 201 815 002 Standalone Memory Test Aborted Program Error with Quick Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off...

Страница 1119: ...BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 816 000 Standalone Memory Test Aborted Program Error with Full Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after e...

Страница 1120: ...and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 816 002 Standalone Memory Test Aborted Program Error with Full Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify support No Use...

Страница 1121: ...ponse Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level ...

Страница 1122: ...OS key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make ...

Страница 1123: ... Test Aborted Unable to Locate SMBIOS key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat D...

Страница 1124: ...l of BMC IMM 201 819 001 Standalone Memory Test Aborted The start end address ranges in the restricted area of the memory Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Tu...

Страница 1125: ...BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 819 003 Standalone Memory Test Aborted The start end address ranges in the restricted area of the memory Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the...

Страница 1126: ...and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 820 001 Standalone Memory Test Aborted Memory Upper limit is less than 16 Mbytes Recoverable No Severity Warning Serviceable No Automatically notify support No User Response ...

Страница 1127: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Lat...

Страница 1128: ...R registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make ...

Страница 1129: ...ange MTRR registers are larger than fixed range MTRR registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1130: ...of DSA Latest level of BMC IMM 201 822 000 Standalone Memory Test Aborted Invalid MTRR service request Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system a...

Страница 1131: ...BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 822 002 Standalone Memory Test Aborted Invalid MTRR service request Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the prob...

Страница 1132: ... seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 824 000 Standalone Memory Test Aborted Node Interleave feature must be OFF Go to Setup and disable Node Interleave option and then re run the test Recoverable No Severity Warning Serviceable No Automatically notify...

Страница 1133: ...plete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA La...

Страница 1134: ...ve option and then re run the test Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconn...

Страница 1135: ...Standalone Memory Test Aborted BIOS Memory Controller has been disabled Go to Setup and Enable Memory Controller Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off th...

Страница 1136: ...pport website Latest level of DSA Latest level of BMC IMM 201 826 003 Standalone Memory Test Aborted BIOS Memory Controller has been disabled Go to Setup and Enable Memory Controller Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the probl...

Страница 1137: ... sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 827 001 Standalone Memory Test Aborted BIOS ECC function has been disabled by BIOS Go to Setup and enable ECC generation Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions ...

Страница 1138: ...ystem and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 827 003 Standalone Memory Test Aborted BIOS ECC function has been disabled by BIOS Go to Setup and enable ECC generation Recoverable No Severity Warning Serviceable No ...

Страница 1139: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Lat...

Страница 1140: ...K registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make ...

Страница 1141: ...set Error Problem clearing MSR machine check control registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1142: ... of BMC IMM 201 845 002 Standalone Memory Test Aborted Chipset Error Problem clearing MSR machine check control registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Tu...

Страница 1143: ...ake sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 859 000 Standalone Memory Test Aborted INVALID XSECSRAT type Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each actio...

Страница 1144: ...and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 859 002 Standalone Memory Test Aborted INVALID XSECSRAT type Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the followi...

Страница 1145: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Lat...

Страница 1146: ...ype 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make ...

Страница 1147: ...01 860 003 Standalone Memory Test Aborted No OEM0 type 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1148: ...vel of DSA Latest level of BMC IMM 201 861 001 Standalone Memory Test Aborted No SRAT type 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and d...

Страница 1149: ...BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 861 003 Standalone Memory Test Aborted No SRAT type 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem rema...

Страница 1150: ...and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 862 001 Standalone Memory Test Aborted No OEM1 structure found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the follo...

Страница 1151: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Lat...

Страница 1152: ...1 structure Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make ...

Страница 1153: ...andalone Memory Test Aborted No IBMERROR key in OEM1 structure Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1154: ...el of DSA Latest level of BMC IMM 201 864 000 Standalone Memory Test Aborted No GAS located in OEM1 Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and ...

Страница 1155: ...BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 864 002 Standalone Memory Test Aborted No GAS located in OEM1 Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem re...

Страница 1156: ...sconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 865 000 Standalone Memory Test Aborted No XSECSRAT key in OEM0 structure Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the f...

Страница 1157: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Lat...

Страница 1158: ...e Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that ...

Страница 1159: ...t Aborted EFI SAL Invalid parameter from GetMemoryMap function Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1160: ...t level of BMC IMM 201 866 003 Standalone Memory Test Aborted EFI SAL Invalid parameter from GetMemoryMap function Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off ...

Страница 1161: ...BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 867 001 Standalone Memory Test Aborted EFI SAL Buffer not allocated Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the prob...

Страница 1162: ...and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 867 003 Standalone Memory Test Aborted EFI SAL Buffer not allocated Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the ...

Страница 1163: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Lat...

Страница 1164: ...p too small Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make ...

Страница 1165: ...t Aborted EFI SAL Invalid parameter from GetMemoryMap function Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1166: ...t level of BMC IMM 201 869 002 Standalone Memory Test Aborted EFI SAL Invalid parameter from GetMemoryMap function Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off ...

Страница 1167: ...hat DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 870 000 Standalone Memory Test Aborted CPU Doamin in ACPI not valid Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2...

Страница 1168: ...and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 870 002 Standalone Memory Test Aborted CPU Doamin in ACPI not valid Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the ...

Страница 1169: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Lat...

Страница 1170: ...encountered Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make ...

Страница 1171: ...t Aborted Data Mis compare encountered Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Re...

Страница 1172: ...MC IMM 201 877 001 Standalone Memory Test Aborted BIOS Sparing in Extended PCI reg must be OFF Go to setup and disable sparing Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative...

Страница 1173: ...BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 877 003 Standalone Memory Test Aborted BIOS Sparing in Extended PCI reg must be OFF Go to setup and disable sparing Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time ...

Страница 1174: ...and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 878 001 Standalone Memory Test Aborted Sparing feature must be turned OFF Go to setup and turn the sparing feature OFF Recoverable No Severity Warning Serviceable No Automati...

Страница 1175: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Lat...

Страница 1176: ...thout cache Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make ...

Страница 1177: ...RR register manipulation Can not write to memory without cache Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1178: ... Latest level of BMC IMM 201 886 000 Standalone Memory Test Aborted Memory Upper limit is less than 16 Mbytes Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the s...

Страница 1179: ...BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 886 002 Standalone Memory Test Aborted Memory Upper limit is less than 16 Mbytes Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action ...

Страница 1180: ...our technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 899 000 Standalone Memory Test Aborted Memory Diagnostics Test Aborted by user Recoverable No Severity Warning Serv...

Страница 1181: ...01 899 002 Standalone Memory Test Aborted Memory Diagnostics Test Aborted by user Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 899 003 Standalone Memory Test Aborted Memory Diagnostics Test Aborted by user Recoverable No Severity Warning Serviceable No Automatically notify support No...

Страница 1182: ...ait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level 5 Replace any DIMMS s mentioned in error one by one 6 Make sure that all DIMMs are enabled in the Configuration Setup Utility program 7 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM S...

Страница 1183: ...IMM 201 901 002 Standalone Memory Test Failed Memory Diagnostics Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power...

Страница 1184: ...evel 5 Replace any DIMMS s mentioned in error one by one 6 Make sure that all DIMMs are enabled in the Configuration Setup Utility program 7 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA memory stress test results The following messa...

Страница 1185: ...un the test again 4 If the system has stopped responding turn off and restart the system 5 Check the system firmware level and upgrade if necessary 6 Run the memory diagnostic to identify the specific failing DIMM 7 If the failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of...

Страница 1186: ...evel of BMC IMM 202 901 000 MemStr Test Failed Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Execute the standard DSA memory diagnostics to validate all memory 2 Make sure that the DSA Diagnostic code is at the latest level 3 Turn off the system and disconnect it from power 4 Reseat the memory cards and DIMMs ...

Страница 1187: ...ed by checking the Available System Memory in the Resource Utilization section of the DSA Diagnostic Event log 2 If necessary access the Configuration Setup Utility program by pressing F1 during system boot and enable all memory 3 Make sure that the DSA Diagnostic code is at the latest level 4 Run the test again 5 Execute the standard DSA memory diagnostics to validate all memory 6 If the failure ...

Страница 1188: ...te Latest level of DSA Latest level of BMC IMM 409 003 000 Nvidia DiagnosticServiceProvider Bandwidth Test Passed Nvidia GPU Bandwidth test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 004 000 Nvidia DiagnosticServiceProvider Query Test Passed Nvidia GPU Query test passed Recove...

Страница 1189: ...support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 006 000 Nvidia DiagnosticServiceProvider Binomial Test Passed Nvidia GPU Binomial test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 800 000 NVIDIA User Diagnostic Test Aborted NVIDIA Use...

Страница 1190: ...led Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 804 000 Nvidia DiagnosticServiceProvider Query Test Aborted Nvidia GPU Query test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA 1178 HX...

Страница 1191: ...A Latest level of BMC IMM 409 806 000 Nvidia DiagnosticServiceProvider Binomial Test Aborted Nvidia GPU Binomial test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 900 000 NVIDIA User Diagnostic Test Failed NVIDIA User Diagnostic Test Failed Recoverable No Severity Event ...

Страница 1192: ...rovider Bandwidth Test Failed Nvidia GPU Bandwidth Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU Then power cycle the system 2 Verify that the power connectors to the GPU are connected firmly Then power cycle the system 3 Run nvidia ...

Страница 1193: ...ntative Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 905 000 Nvidia DiagnosticServiceProvider Matrix Test Failed Nvidia GPU Matrix Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU Then power cycle th...

Страница 1194: ... q In some cases this will report a poorly connected power cable 4 Rerun the diagnostics using the same GPU on system that is known to be working A variety of system issues can cause diagnostic failure 5 If the problem remains contact your IBM technical support representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA optical drive test results The following ...

Страница 1195: ...atest level 2 Run the test again 3 Check the drive cabling for loose or broken connections at both ends or damage to the cable Replace the cable if damage is present 4 Run the test again 5 Check system firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 6 Run the test again Related link...

Страница 1196: ... system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 215 803 000 Optical Drive Test Failed Optical Drive Test Failed Disk may be in use by the operating system Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Wait for the system ac...

Страница 1197: ... Run the test again 5 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 215 901 000 Optical Drive Test Aborted Optical Drive Test Aborted Drive media is not detected Recoverable No Severity Warning Serviceable Yes Automatically notify suppor...

Страница 1198: ...r 15 seconds for the media to be recognized Rerun the test 2 Check the drive cabling for loose or broken connections at both ends or damage to the cable Replace the cable if damage is present 3 Run the test again 4 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA ...

Страница 1199: ...re remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA system management test results The following messages can result when you run the system management test Test results for the DSA system management test The following messages can result when you...

Страница 1200: ...test level of BMC IMM 166 802 001 IMM I2C Test Aborted Test cannot be completed for unknown reason Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM ar...

Страница 1201: ...evel of BMC IMM 166 804 001 IMM I2C Test Aborted Invalid Command Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related link...

Страница 1202: ...IMM I2C Test Aborted Timeout while processing command Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Suppo...

Страница 1203: ...ted Reservation Canceled or Invalid Reservation ID Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Support ...

Страница 1204: ...overable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 16...

Страница 1205: ...lly notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 813 001 IMM I2C Test Aborted Cannot return number of ...

Страница 1206: ... Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 815 001 IMM I2C Test Aborted Invalid data field in Request Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the acti...

Страница 1207: ...Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 817 001 IMM I2C Test Aborted Command response could not be provided Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each actio...

Страница 1208: ...he latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 819 001 IMM I2C Test Aborted Command response could not be provided SDR Repository in update mode Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disco...

Страница 1209: ... latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 821 001 IMM I2C Test Aborted Command response could not be provided BMC initialization in progress Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and discon...

Страница 1210: ...level of DSA Latest level of BMC IMM 166 823 001 IMM I2C Test Aborted Cannot execute command Insufficient privilege level Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure ...

Страница 1211: ... IMM Indicates failure in PCA9557 I2C I O Expander bus BUS 3 Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level 3 Run the test aga...

Страница 1212: ...rrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 908 001 IMM I2C Test Failed IMM Indicates failure in PCA9545 failure in 4 Channel I2C Switch bus BUS 7 Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and di...

Страница 1213: ...e Test Passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 264 901 000 Tape Test Failed An error was found in the tape alert log Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Clean the tape drive using the appropr...

Страница 1214: ...ble Yes Automatically notify support No User Response Complete the following steps 1 Clean the tape drive using the appropriate cleaning media and install new media 2 Run the test again 3 Make sure that the drive firmware is at the latest level 4 Rerun the test after upgrading to the latest firmware level 5 If the failure remains refer to Troubleshooting by symptom in the system Installation and S...

Страница 1215: ...e Test Failed Drive hardware error Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check the tape drive cabling for loose or broken connections or damage to the cable Replace the cable if damage is present 2 Clean the tape drive using the appropriate cleaning media and install new media 3 Run the test again 4 Make sure that...

Страница 1216: ...restart the system 5 Make sure that the drive firmware is at the latest level 6 Run the test again 7 If the failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 264 906 000 Tape Test Failed Tape Test Failed Unrecognized error Recoverable No Severi...

Страница 1217: ... Latest level of DSA Latest level of BMC IMM 264 907 000 Tape Test Failed An error was found in the block address somewhere Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Clean the tape drive using the appropriate cleaning media and install new media Related links IBM Support website Latest level of DSA Latest level of BMC...

Страница 1218: ...re that medium is present 2 Clean the tape drive using the appropriate cleaning media and install new media Related links IBM Support website Latest level of DSA Latest level of BMC IMM 1206 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 1219: ...have installed new hardware or software in your environment check http www lenovo com serverproven to make sure that the hardware and software is supported by your product Go to http www lenovo com support to check for information to help you solve the problem Gather the following information to provide to the service technician This data will help the service technician quickly provide a solution...

Страница 1220: ...tp www lenovo com support The most current version of the product documentation is available in the following product specific Information Centers Flex System products http pic dhe ibm com infocenter flexsys information index jsp System x products http shop lenovo com us en systems NeXtScale System products http pic dhe ibm com infocenter nxtscale documentation index jsp How to send DSA data You c...

Страница 1221: ...anada call 1 800 IBM SERV 1 800 426 7378 Hardware service and support IBM is Lenovo s preferred service provider for the System x Flex System and NeXtScale System products You can receive hardware service through your Lenovo reseller or from IBM To locate a reseller authorized by Lenovo to provide warranty service go to http www ibm com partnerworld and click Business Partner Locator For IBM suppo...

Страница 1222: ...1210 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 1223: ...ublication Lenovo may make improvements and or changes in the product s and or the program s described in this publication at any time without notice The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo...

Страница 1224: ...d disk drive bays with the largest currently supported drives that are available from Lenovo Maximum memory might require replacement of the standard memory with an optional memory module Each solid state memory cell has an intrinsic finite number of write cycles that the cell can incur Therefore a solid state device has a maximum number of write cycles that it can be subjected to expressed as tot...

Страница 1225: ...tered to 99 97 efficiency or greater using high efficiency particulate air HEPA filters that meet MIL STD 282 The deliquescent relative humidity of the particulate contamination must be more than 60 2 The room must be free of conductive contamination such as zinc whiskers Gaseous Copper Class G1 as per ANSI ISA 71 04 19853 Silver Corrosion rate of less than 300 Å in 30 days 1 ASHRAE 52 2 2008 Meth...

Страница 1226: ...quired to take adequate measures European Union EMC Directive conformance statement This product is in conformity with the protection requirements of EU Council Directive 2014 30 EU on the approximation of the laws of the Member States relating to electromagnetic compatibility Lenovo cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non recommende...

Страница 1227: ...n EMVG das EG Konformitätszeichen CE zu führen Verantwortlich für die Konformitätserklärung nach Paragraf 5 des EMVG ist die Lenovo Deutschland GmbH Meitnerstr 9 D 70563 Stuttgart Informationen in Hinsicht EMVG Paragraf 4 Abs 1 4 Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse A Nach der EN 55022 Dies ist eine Einrichtung der Klasse A Diese Einrichtung kann im Wohnberei...

Страница 1228: ...guideline Japanese Statement of Compliance for Products More than 20A Korea Communications Commission KCC statement This is electromagnetic wave compatibility equipment for business Type A Sellers and users need to pay attention to it This is for any areas other than home Russia Electromagnetic Interference EMI Class A statement 1216 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 1229: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1217 ...

Страница 1230: ...Taiwan BSMI RoHS declaration 1218 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 1231: ...ackplane 115 8x3 5 inch drive backplane 115 the 24x2 5 inch hot swap drive backplane 114 the 8x2 5 inch hot swap drive backplane 112 VGA 111 call home feature Electronic Service Agent 64 call home tools 64 Canada Class A electronic emission statement 1214 caution statements 5 checkout procedure 54 performing 54 China Class A electronic emission statement 1217 Class A electronic emission notice 121...

Страница 1232: ...emoving 157 replacing 167 electronic emission Class A notice 1214 Electronic Service Agent 64 Enterprise X Architecture technology 10 error codes and messages IMM2 229 error messages 64 error symptoms general 64 hard disk drive 65 intermittent 66 keyboard 67 memory 68 microprocessor 69 monitor 69 mouse 67 network connection 71 power 72 serial port 79 ServerGuide 80 software 80 USB connector 80 USB...

Страница 1233: ... LED 58 IMM2 Web interface 42 important notices 5 1212 in band automated boot recovery method 88 manual recovery method 86 information center 1208 installing DIMM 129 lightpath LCD operation panel assembly 141 media cage 141 memory module 129 SATADOM 205 integrated management module overview 10 using 40 integrated management module II error messages 229 event log 59 60 programs 34 intermittent pro...

Страница 1234: ...ailure 89 O obtaining 41 42 OneCLI log 60 online documentation 1 online publications 4 operating system event log 59 60 operator information panel controls and LEDs 15 removing 202 replacing 203 operator information panel release latch 14 optional devices connectors system board 26 out of band 88 P particulate contamination 1213 parts listing 91 parts consumable 97 parts structural 97 PCI riser sl...

Страница 1235: ...swap fan 137 hot swap hard disk drive 125 LCD system information display panel 194 lightpath LCD operation panel assembly 139 media cage 139 memory module 128 microprocessor 207 operator information panel 202 power paddle module 121 SATADOM 205 system board 223 top cover 116 Replaceable server components 91 replacing adapter 152 156 air baffle 120 battery system 192 components 101 dedicated slotle...

Страница 1236: ...page custom 1209 switches system board 26 symmetric multiprocessing 10 system error LED front 15 locator LED front 15 System information LED 15 system board buttons 26 external connectors 25 internal connectors 24 jumpers 26 LEDs 29 removing 223 replacing 226 switches 26 system board optional devices connectors 26 system event log 60 system pulse LEDs 58 system reliability guidelines 102 system ev...

Страница 1237: ...5 the remote presence feature 41 utility Setup 34 starting 35 using 35 V video connector front 14 viewing event log 60 W Wake on LAN feature 31 weight 5 what the server offers 10 working inside the server power on 103 X X Architecture technology 10 Copyright Lenovo 2016 2017 1225 ...

Страница 1238: ...1226 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...

Страница 1239: ......

Страница 1240: ......

Отзывы: