Compatibility with Other Versions of Access-T
The Access-T 100-S and Access-T RDL are compatible with other versions of
Access-T. However, if you plan to use the Access-T 100-S or Access-T RDL in
combination with other Access-Ts, please be aware of the following issues:
•
The Access-T 100-S or Access-T RDL cannot act as the master on a chain
that has other versions of Access-T (Access-T 100, 200, 400, or 1500).
•
The
SYSTEM
→
CHAIN PORT
→
CONFIG COPY
command does not copy all
parameters from the master to slave units when the chain consists of
mixed Access-T 100-S/Access-T RDL and other Access-Ts.
•
In a master/slave configuration, the
COMMANDS
→
RESET SYSTEM DE-
FAULTS
command does not function properly if both the master and
slave units are Access-T 100-S.
•
Access-T 100-S and Access-T RDL do not display an on-screen Alert
if they are the master of a chain and a slave unit is removed from the
chain. The Chain Poll History screen does display the correct alarm.
•
Access-T can send Yellow Signal when it has lost sync on the received
T1 signal. The default for this parameter for Access-T 100-S and
Access-T RDL is
ON
. For other versions of Access-T (Access-T 100, 200,
400, or 1500), the default is
OFF
.
•
If using SNMP to configure Access-T 100-S or Access-T RDL, the SET
command does not function with the dsx1ConfigTable object. Con-
figuration settings must be made via the Terminal Interface.
•
A few screens and menu paths appear slightly different from other
versions of Access-T. However, these differences do not affect per-
formance.