dsx1LineStatus
This read-only object provides the status of the local Access-T DS1 line interface:
MIB Values
Description
dsx1NoAlarm (1 )
No alarm present
dsx1RcvFarEndLOF (2)
Local Access-T receiving Yellow Alarm
dsx1RcvAlS (8)
Local Access-T receiving AIS
dsx1LossOfFrame (32)
Local Access-T Loss of Frame condition
dsx1LossOfSignal (64)
Local Access-T Loss of Signal condition
dsx1LoopbackStatus(128) Local Access-T LS or DS Line Loopback or
LS or DS DTE Loopback active
other failures (4096)
The dsx1LineStatus is a bit-mapped variable (i.e., the value returned will be the
total of all current alarm conditions). For example, if there is an LOS condition,
there will also be an LOF condition and Yellow Signal (TYEL ) will be generated;
thus, the dsx1LineStatus value will be 64 + 32 + 4 = 100.
dsx1SignalMode
This read-write object indicates the signaling method used between the local
and far-end Access-Ts. This object applies only to Access-Ts configured as a
master.
MIB Value
Description
none ( 1 )
No bits reserved for signaling
dsx1TransmitClockSource
This read-write object selects or indicates Access-Ts Transmit clock source:
MIB Values
Description
loopTiming (1)
Loop timing from the DS1 line interface
localTiming (2)
Internal clock source
throughtiming (3)
External clock source
The dsx1TransmitClockSource selects the configured clock source. If automatic
clock switching is enabled, this object returns the clock source that was config-
ured, which might be different than the current clock source.
Appendix G