Figure 7-8. One-Hour Statistics Display
5. Press the
Esc
key to return to the register type prompt.
6.
Select another register type as described in step 2, or press the
Esc
key
to return to the Main Menu Line.
Clearing the Registers
The Clear Registers command (
COMMANDS—CLEAR REGISTERS
) resets to zero all
error and interval counts for the following:
•
The User, FDL User, or Aux 24-hour registers and one-hour statistics.
•
The line availability percentage (based on the User UAS register).
The Telco registers, one-hour statistics, and ESF error count are unaffected by
the Clear 24-Hour Registers command.
Note:
When FDL User is selected, Access-T sends an FDL
command and does not wait for a response. To verify that the
far-end registers have been cleared, you must display the
registers via the report menu.
To clear the 24-hour registers, follow these steps:
1.
Select
COMMANDS
from the Main Menu Line.
2.
Select
CLEAR REGISTERS
.
3.
Select the register count to be cleared:
USER, AUX PORT
, or
FDL USER
.
— TELCO ONE-HOUR STATISTICS
date and time
CURRENT INTERVAL
251 seconds
VALID INTERVALS
96
ES
UAS
BES
SES
CSS
LOFC
24-HOUR TOTAL:
51
9
20
36
0
2
CURRENT COUNt:
3
0
0
0
0
0
Interval 1
0
0
0
0
0
0
Interval 2
0
0
0
0
0
0
Interval 3
7
0
5
2
0
0
Interval 4
0
0
0
0
0
0