dsx1Fdl
This read-write object selects or indicates the mode of the facility data link (FDL).
MIB Values
Description
dsx1Ansi-T1-403 (2)
ANSI T1.403 ESF framing with T1.403 enabled
dsx1Att-54016 (4)
AT&T 54016 ESF framing with T1.403 disabled
dsx1Att-54016 (6)
AT&T 54016 ESF framing with T1.403 enabled
dsx1 Fdl-none (8)
D4 framing
If the DS1 line interface framing mode changes (dsx1LineType) from ESF to D4,
dsx1Fdl-none becomes the default automatically. If the DS1 line interface fram-
ing mode changes (dsx1 LineType) from D4 to ESF, the choice of ESF standards
will depend on the current dsx1Dfl value.
The dsx1Fdl is a bit-mapped variable (i.e., the value returned will be the total
of the MIB values). For instance, when Access-T is configured for ANSI T1.403,
it also supports AT&T 54016; thus, the dsx1Fdl value is 4 + 2 = 6.
dsx1CurrentTable
This read-only table contains various performance statistics being collected for
the current 15-minute interval. Since Access-T only has one line interface, the
table contains only one instance.
dsx1Currentlndex
This read-only object identifies the DS1-x line interface. It is equal to “ifIndex”
(3), which is equal to “dsx1LineIndex”. This object applies only to Access-Ts
configured as a master.
ACST-0351-005
Appendix G
June 1996
Access-T DS1 MIB Support
G–5