Line (T1 or FT1 Network)
Access-T Series 100, 200, and 400 Units
The
LINE
connector is a standard DA15 male connector. Figure 3-10 shows the
required wiring to the
LINE
connector.
Larscom offers cables using DA15 or RJ48 connectors, plus a DA15-to-RJ48
adapter. See Table 9-A for the part numbers of all Larscom cables and adapters.
See Appendix A for the illustrations of all Larscom cable connections.
NOTICE: Before connecting to a public T1 or FT1 serv-
ice, read the
Notice to Users (page xiv). Do not make any
connection to the T1 line until the telephone company
has been given the required notice. Notification must be
in the form of a notarized affidavit and is generally
required at least ten days prior to connection to the net-
work. Details of the notification requirements are avail-
able from your telephone company.
CAUTION: Be careful whenever installing or modifying
telephone lines. Specifically:
•
Never install telephone wiring during a lightning
storm.
•
Never install a telephone jack in a wet location
unless the jack is specifically designed for wet
locations.
•
Never touch uninsulated telephone wire or termi-
nals unless the telephone line has been discon-
nected at the network interface.
To connect Access-T to the T1 or FT1 network, follow these steps:
1. Determine the cable to be used to connect the
LINE
connector and the
Network Interface (NI).
2.
Install the appropriate cable between the
LINE
connector,
J8
, and the
Network Interface (NI), making sure that each connector is oriented
properly and mated securely.
ACST-0351-005
Chapter 3
June 1996
Installation
3-17