One-Hour Statistics
The One-Hour Statistics command (
REPORTS—ONE-HOUR STATISTICS
) displays in
a single report the 24-hour error count and a 1-hour error breakdown for six
performance parameters:
•
Errored Seconds (ES)—maximum value of 65,535.
•
Unavailable Seconds (UAS)—maximum value of 65,535.
•
Bursty Errored Seconds (BES)—maximum value of 65,535.
•
Severely Errored Seconds (SES)—maximum value of 65,535.
•
Controlled Slip Seconds (CSS)—maximum value of 255 (only avail-
able via the FDL when supported by the far-end equipment).
•
Loss of Frame Count (LOFC)—maximum value of 255.
Like the 24-Hour Register report, the One-Hour Statistics report can display
Telco, User, or Aux register contents from the local Access-T, or Telco and User
register contents from the far-end Access-T or other device via the FDL.
Display Format
The one-hour statistics report is shown in Figure 7-8. The one-hour period is
divided into 15-minute intervals. The top line of the report gives the register
type (User,Telco, Aux Port, FDL Telco, or FDL User), parameter type, name of
the unit, and time. Line 2 of the report gives the number of seconds (maximum
900) in the current (incomplete) interval. Line 3 identifies the number of valid
complete intervals (reset at power-up or register clearing). The balance of the
report gives error counts for the current interval, the last hour (i.e., the valid
intervals), and intervals 1 (most recent) through 4.
Errors continue to be counted while a diagnostic is in progress (i.e., the Access-T
is in loopback or is transmitting a test signal). Statistics are cleared on power-up
or when the framing mode is changed. User statistics are also cleared by the
Clear Registers command (
COMMANDS—CLEAR REGISTERS
). Telco statistics can be
cleared by a command from the network (i.e., by the telco).
To display a one-hour report, perform the following steps:
1.
Select
REPORTS
from the Main Menu Line.
2.
Select
ONE-HOUR STATISTICS
.
3.
Select the desired register type (
User
,
Telco
,
Aux
,
FDL Telco
, or
FDL User
).
4.
The report will be displayed on the terminal screen.
ACST-0351-005
Chapter 7
June 1996
Alarms, Reports, and Tests