Line Availability
The Line Availability command (
REPORTS—LINE AVAILABILITY
) displays the per-
centage of seconds which were not Unavailable Seconds. The percentage is
based on the current interval and the valid intervals in the User 24-Hour
Unavailable Seconds register.
Line availability is displayed as illustrated in Figure 7-10. The display gives the
availability percentage and the number of seconds on which the calculation is
based. Line availability continues to be calculated while a diagnostic is in
progress (i.e., the Access-T is in loopback or is transmitting a test signal).
Line availability is cleared when the User 24-hour registers are cleared.
To display the Line Availability, perform the following steps:
1.
Select
REPORTS
from the Main Menu Line.
2.
Select
LINE AVAILABILITY
.
3.
The Line Availability percentage is displayed on the terminal screen.
4.
Press the
Esc
key to return to the Main Menu Line.
Note:
If the UAS count exceeds 65,534, the message
Availability not calculable —Excessive errors / Press EXIT Key to
Continue
will be displayed.
Figure 7-10. Line Availability Display
—
LINE AVAILABILITY —
date and time
Availability 98.1% over the last 86,439 seconds
Press EXIT Key to Continue.
ACST-0351-005