Copying a Node’s Configuration
Via a master, you can copy the configuration of one node to another node over
the Chain Port. When this command is requested, Access-T downloads the
following configuration information:
•
Map configuration (map 1, map 2, current mode, and switch time).
•
All alarm configurations (enable and dialout) except chain polling.
•
System clock information (source clock and frequency).
•
DTE port configuration (rate, clock, data, interface, RTS, TTM, and
Bit 7).
•
Line/Aux framing and coding and equalization.
•
Line Build-Out and Equalization.
•
Yellow Signal generation.
•
T1.403.
•
Line BPV/ES threshold configuration (threshold and interval).
•
Aux ES threshold configuration (threshold and interval).
•
Bit 7 stuffing.
•
In-band loopback recognition.
•
Yellow Signal transcoding.
•
AIS-to-DTE and AIS-to-Line.
•
Data Link ID.
To copy the configuration of one node to another, perform the following steps:
1.
Select
SYSTEM
from the Main Menu Line.
2.
Select
CHAIN PORT
.
3.
Select
CONFIG COPY
. A dialog box appears at the bottom of the display.
4.
Key-in the 2-digit node address of the source node (node with con-
figuration to be duplicated) followed by the 2-digit node address of
the destination node (node which will receive the copies configura-
tion) and press the
Enter
key.
5.
Press the
Esc
key twice to return to the Main Menu Line.
ACST-0351-005
Chapter 8
June 1996
Using Access-T as a Master
8-7