Message explanations
A-44
385585/C
Position status error
Description:
This message is reported if a status in the position data from the HPR system
indicates that the data received is not valid.
Possible
consequences:
Position measurements from the HPR that provides the invalid data will be
rejected.
Corrective
actions:
No actions necessary if the alarm situation occurs only now and then.
If the alarm is repeated frequently, enable another position reference system.
Check the HPR system that provides the invalid data.
Position status invalid
Description:
This message is reported if a status in the position data from the HPR system
indicates that the data received is not valid.
Possible
consequences:
Position measurements from the HPR that provides the invalid data will be
rejected.
Corrective
actions:
No actions necessary if the alarm situation occurs only now and then.
If the alarm is repeated frequently, enable another position reference system.
Check the HPR system that provides the invalid data.
Power 24V failed
Description:
An external 24V IO Power has failed.
Possible
consequences:
Depending on your power configuration, some external sensors may have
stopped.
Corrective tions:
•
Inspect and possibly replace fuse.
•
If power supply is failed, replace it.
•
Contact Kongsberg Maritime Service if this does not solve the problem.
Power failure backupgyro
Description:
This is a digital input indicating that a backup gyro has power supply failure on
one of its dual power sources. The reason for this fault may be missing power
input to gyro.
Possible
consequences:
Backup gyro will run on secondary power supply.
Corrective
actions:
Check gyro for the backup system.