To enable the position-reference system, proceed as follows:
1
Display the Sensor Enable input dialog.
2
Move the focus to the
Enable
field for the position-reference system and change
the option to
On
.
3
Press the
Enter
button.
• An initial calibration of the position-reference system is performed.
• When the position-reference system has been calibrated and acceptable position
measurements are being received, the
Ready
field for the position-reference
system changes to green.
4
Close the Sensor Enable input dialog.
5
Check on the Position-reference System view that the
Status
field shows
Online
for
the position-reference system.
• This also indicates that acceptable position measurements are being received and
that the calibration process was successful.
6
Check that the following information message is displayed in the Message Line (or,
if no longer displayed, on the Message view):
Reference origin <system>
• The origin of the position-reference system is now being used as the reference
origin.
Disabling the position-reference system
To disable the position-reference system, proceed as follows:
1
Display the Sensor Enable input dialog.
2
Move the focus to the
Enable
field for the position-reference system and change
the option to
Off
.
3
Press the
Enter
button.
• The position-reference system is disabled and this is indicated by the
Ready
field
for the position-reference system changing to red.
4
Close the Sensor Enable input dialog.
5
Check on the Position-reference System view that the
Status
field for the
position-reference system shows
Offline
.
Position dropout
If the vessel position is under automatic control and all position-reference input is lost
or rejected, the following warning message is displayed:
All reference systems rejected
After 20 seconds without reference input, the following alarm is given:
385585/C
107