Message explanations
A-82
385585/C
Corrective
actions:
Some extra information is found in a system message received simultaneously as
the alarm : "Unknown error. Testno=xx Address=xx ErrorData=xx". Note the
alarm/message texts, describe the current operation executed and contact
Kongsberg Maritime Service.
UPS earth failure
Description:
This is a digital input indicating a UPS (Uninterruptible Power Supply) warning. It
may be an earth failure detected by the UPS.
Corrective
actions:
Check UPS.
UPS failure
Description:
This is a digital input indicating a UPS (Uninterruptible Power Supply) failure.
The reason for this fault may be power input to UPS missing, UPS breakdown or
internal UPS error.
Possible
consequences:
Generally the consequences are serious.
Corrective
actions:
Check UPS.
The vessel should not be on DP.
UTM zone offset
Description:
This message is reported if the difference between the system UTM (Universal
Transversal Mercator) zone and the actual position exceeds a limit where accuracy
of displayed coordinates will be degraded. Also the difference between the true
heading and grid heading will be large.
The reason for this fault is that the manually selected UTM-zone is wrong or
position has changed significantly since the start of DP mode.
The method of detection is that the Actual Position is compared to zone.
Additional
information:
•
System UTM zone
•
Actual deviation from center of UTM zone in degrees
Possible
consequences:
Inaccurate position data in display.
Corrective
actions:
Change UTM-zone for display.
VRS [#] not ready
See “Sensor [#] not ready”.