Message explanations
A-16
385585/C
Driver task creation error
Description:
This message shall not occur during normal operation, but is intended to be an aid
for the software engineer during configuration/commissioning.
Corrective
actions:
Should the message occur during normal operation, contact Kongsberg Maritime
service.
DSP error (see message)
Description:
The Digital Signal Processor (DSP) used for processing IO, is reporting error.
Possible
consequences:
The consequences depends on the type of failure, described in the corresponding
message reported simultaneously as the alarm:
•
(1): DSP error: IO bus not operational. WDOG stop time: xx Last updated:
xx
•
(2): DSP error: IO controller reporting BITE error: xx.
If (1), the IO processing may have been stopped. If (2), IO processing is not
functioning properly.
Corrective
actions:
•
If possible, try to replace the PS (Process Station).
Note the alarm/message texts, describe the current operation executed and
enclose this data when delivering the PS to Kongsberg Maritime Service for repair.
Dual connection generator [#]
Description
This message is reported if at least two connections are found for a generator.
The reason for the fault may be an error in the digital input interface or in the
cabling.
The method of detection is by monitoring the digital input signals.
Additional
information
Possible
consequences
The DP system will treat the generator as if it is connected to all the swbds. The
DP system will therefore calculate with too high power available on the swbd(s) for
which the connect signal is wrong. This might cause the DP system to erroneously
not limit the thrust on the affected thrusters.
Corrective
actions
Verify proper connect status with engine control room.
Check cabling. Replace appropriate input interface.
ECC is disabled (see message)
Description:
This error will be reported if the PS (Process Station) has been started with the
mode wheel to 0x5 or 0xd.
If this is not the case, this error indicates a memory failure.