Message explanations
385585/C
A-81
Corrective
actions:
If required, enable another reference system/sensor.
Check the reference system/sensor.
Check the cabling and connections.
Replace SBC and check reference system hardware.
Tunnel [#] input error pitch
See “Thruster/rudder [#] input error”.
Tunnel [#] not ready
See “Thruster/rudder [#] not ready”.
Tunnel [#] prediction error pitch
See “Thruster/rudder [#] prediction error”.
Unconnected IO blocks
Description:
IO configuration error.
This message shall not occur during normal operation, but is intended to be an aid
for the software engineer during configuration/commissioning.
Possible
consequences:
System may not work properly.
Corrective
actions:
Should this message occur during normal operation, contact Kongsberg Maritime
Service.
Unconnected IO modules
Description:
IO configuration error.
This message shall not occur during normal operation, but is intended to be an aid
for the software engineer during configuration/commissioning.
Possible
consequences:
System may not work properly.
Corrective
actions:
Should this message occur during normal operation, contact Kongsberg Maritime
Service.
Unknown error (see message)
Description:
The reason is probably that the release you are using are missing the proper error
handling for a BITE-related Built In Test Equipment) error for a specific target.
Possible
consequences:
Due to the missing handling of this error, there is no simple way of finding out the
consequences.