Note
To turn off the operator terminal, its 24 VDC power supply must be switched off in
the joystick controller cabinet. For further details, refer to the Maintenance Manual
for your vessel.
Restarting the operator terminal
If for some reason, you are required to shut down and restart the operator terminal, then it
should be done in a controlled manner using the
Restart this Operator Terminal
function
(see
Software Upgrade and Restart input dialog
on page 59).
Caution
Before attempting to shut down and restart an operator terminal you must
ensure that the operator terminal is in Standby mode and does not have
control of the vessel's propulsion system.
To shut down and restart the operator terminal in a controlled manner, proceed as follows:
1
Display the Software Upgrade and Restart input dialog.
2
Move the focus to the
Restart this Operator Terminal
field and change the option to
Yes
.
3
Press the
Enter
button.
• The operator pop-up message
The Operator Terminal will be restarted...
is
displayed.
• The application software is shut down.
• The Microsoft Windows message
System Shutdown
is displayed.
• After a few seconds, the operating system is shut down.
• When the operating system has been shut down the audible signal horn sounds.
• A few seconds after the audible signal horn starts sounding, the operating system
automatically starts to reload.
4
Press the
Silence/ack.
button.
• The audible signal is silenced.
5
When the operating system and application software have been reloaded and the
operator terminal is running, display the Software Upgrade and Restart input dialog.
6
Check that the colour of the single
Operator Terminal Status
field and the six
Remote
Control Unit Status
fields are green.
385585/C