• At all other terminals, the information (
INFO:
) or operator pop-up message
Receiving Command
is displayed, the audible signal horn sounds and the
Take
button status indicator starts to flash.
2
At the terminal where command is to be taken, press the
Take
button twice within
four seconds.
• Command is transferred to the terminal, the information (
INFO:
) or operator
pop-up message
Command obtained
is displayed, the audible signal is silenced
and the
Take
button status indicator becomes steadily lit.
• At the operator terminal from which command was given, the operator pop-up
message
Not in Command any more
is displayed, the audible signal is silenced,
and the
Take
button status indicator stops flashing and becomes unlit.
• At all other terminals, the information (
INFO:
) message
Command Ended
is
displayed, the audible signal is silenced, and the
Take
button status indicator
stops flashing and becomes unlit.
If the
Take
button is pressed at the operator terminal giving command or the “Give
Command” times out, the operator pop-up message
Giving Command Ended
is displayed,
the audible signal is silenced, and the
Take
button status indicator stops flashing and
becomes unlit. At all other terminals the information (
INFO:
) or operator pop-up
message
Receiving Command Ended
is displayed, the audible signal is silenced, and the
Take
button status indicator stops flashing and becomes unlit.
Panel test
The buttons, indicators and audible signal horn on the operator terminal can be tested by
means of the panel test function.
Note
System operation is blocked when the panel test is enabled. It is therefore recommended
to perform the test in Standby mode or before taking command at the operator terminal.
The panel test is automatically terminated if no buttons are pressed within a preset
time limit.
To perform the panel test, proceed as follows:
1
Press the
Test
button.
• The panel test function is enabled.
• All the button status indicators flash green/red.
• The audible signal sounds.
• The
operation
indicator flashes green/red.
2
Press the
Silence/ack.
button to stop the audible signal from sounding.
3
Press each button (except for
Test
), one at a time.
• If applicable, the status indicator associated with the pressed button is
extinguished.