76 Language Dictionary
Initiate Subsystem
This subsystem enables the trigger system.
INIT
INIT:CONT
When a trigger is enabled with this command, an event on a selected trigger source causes the specified trigging action to
occur. If the trigger subsystem is not enabled, all trigger commands are ignored. If
INIT:CONT
is
OFF,
then
INIT
enables the trigger subsystem only for a single trigger action. The subsystem must be enabled prior to each subsequent
trigger action. If
INIT:CONT
is
ON,
then the trigger subsystem is continuously enabled and
INIT
is redundant.
Command Syntax
INITiate[:IMMediate]
INITiate:CONTinuous <bool>
Parameters
For
INIT[:IMM]
(None)
For
INIT:CONT 0|1|OFF|ON
*RST Value
OFF
Examples
INIT
INITIATE:IMMEDIATE
INIT:CONT 1
INITIATE:CONTINUOUS
1
Query Syntax
For
INIT[:IMM]
(None)
For
INIT:CONT INIT:CONT?
Returned Parameters
<NR1>
0
|
1
Related Commands
ABOR <GET> *RST TRIG *TRG
Measure Subsystem
This subsystem returns output measurements.
MEAS:CURR?
MEAS:VOLT?
These queries return the voltage and current measured at the power supply's sense terminals.
Query Syntax
MEASure:CURRent[:DC]? MEASure:VOLTage[:DC]?
Parameters
(None)
Default Suffix
A
for
MEAS:CURR?
V
for
MEAS:VOLT?
Examples
MEAS:CURR?
MEAS:VOLT?
MEASURE:VOLTAGE:DC? MV
Returned Parameters
<NR3>