NOTICE:
•
Verify the driver settings before you start any pump. Refer to the applicable drive
equipment IOMs and operating procedures.
•
Excessive warm-up rates can cause equipment damage. Ensure the warm-up rate
does not exceed 1.4°C | 2.5°F per minute.
•
The mechanical seal used in an Ex-classified environment must be properly certified.
NOTICE:
You must follow these precautions before you start the pump:
•
Flush and clean the system thoroughly to remove dirt or debris in the pipe system in
order to prevent premature failure at initial startup.
•
Bring variable-speed drivers to the rated speed as quickly as possible.
•
Run a new or rebuilt pump at a speed that provides enough flow to flush and cool the
close-running surfaces of the stuffing-box bushing.
•
If temperatures of the pumped fluid will exceed 93°C | 200°F, then warm up the pump
prior to operation. Circulate a small amount of fluid through the pump until the casing
temperature is within 38°C | 100°F of the fluid temperature. Accomplish this by flowing
fluid from pump inlet to discharge drain (optionally, the casing vent can be included in
warm-up circuit but not required). Soak for (2) hours at process fluid temperature.
At initial startup, do not adjust the variable-speed drivers or check for speed governor or over-speed
trip settings while the variable-speed driver is coupled to the pump. If the settings have not been veri-
fied, then uncouple the unit and refer to instructions supplied by the driver manufacturer.
5.2 Remove the coupling guard
1.
Remove the nut, bolt, and washers from the slotted hole in the center of the coupling guard.
2.
Slide the driver half of the coupling guard toward the pump.
Driver
3.
Remove the nut, bolt, and washers from the driver half of the coupling guard.
4.
Remove the driver half of the coupling guard:
a) Slightly spread the bottom apart.
b) Lift upwards.
5.
Remove the remaining nut, bolt, and washers from the pump half of the coupling guard.
5.2 Remove the coupling guard