NOTICE:
Grease can settle in equipment left idle leaving bearings improperly lubricated. Check the
greasing on a pump that has been out of service for a long period of time and re-grease if
necessary.
Pumps are shipped without oil. You must lubricate oil-lubricated bearings at the job site.
Grease-lubricated bearings are lubricated at the factory.
The bearing manufacturer fills greased-for-life bearings with grease and seals them at the factory.
You do not need to lubricate or seal these bearings.
5.6.1 Lubricating oil requirements
Oil quality requirements
Use a high-quality turbine oil with rust and oxidation inhibitors.
Lubricating oil type
•
CLP46
•
DIN 51517
•
HD 20W/20 SAE
Symbol
DIN 51502
Kinematic viscosity at 40°C | 104°F
46 ±4 mm
2
/sec |
0.0713 ±0.006 in.
2
/sec
Flash point (Cleveland)
175°C | 347°F
Setting point (Pourpoint)
-15°C | 5°F
Application temperature
(Contact your ITT representative to determine a suita-
ble type of lubrication if ambient temperatures are be-
low -10°C | 14°F.
Higher than permitted bearing temperature
Oil quantity requirements
Bearing frame size
Oil quantity in liters | quarts
24
0.5 | 0.53
32
1.1 | 1.16
42
1.4 | 1.48
48
1.7 | 1.8
5.6.2 Lubricate the bearings with oil
WARNING:
Risk of explosive hazard and premature failure from sparks and heat generation. En-
sure bearings are properly lubricated prior to startup.
NOTICE:
The pump is not filled with oil when delivered. Fill with oil before operating the pump.
•
Determine which procedure to use in order to fill the bearing frame with oil:
If...
Then...
The pump has an oil level sight glass (stand-
ard design)
Use the "Fill the bearing frame with oil" proce-
dure.
The pump has a constant level oiler (option-
al)
Use the "Fill the bearing frame with an optional
oiler" procedure.
5.6 Bearing lubrication