NOTICE:
Auxiliary cooling and flush systems must be operating properly to prevent excess heat gen-
eration, sparks, and/or premature failure. Ensure auxiliary piping is installed as specified on
the pump data sheet prior to startup.
When to install
You may need to install auxiliary piping for bearing cooling, mechanical seal flush, or other special
features supplied with the pump. Consult the pump data sheet for specific auxiliary piping recommen-
dations.
Checklist
Check
Explanation/comment
Checked
Check that the minimum flow for each
component is 4 lpm | 1 gpm.
–
Check that the cooling water pressure
does not exceed 7.0 kg/cm
2
| 100 psig .
–
4.6.7 Final piping checklist
Check
Explanation/comment
Checked
Check that the shaft rotates smoothly.
Rotate the shaft by hand. Make sure there is no rubbing
that can lead to excess heat generation or sparks.
Re-check the alignment to make sure that
pipe strain has not caused any misalign-
ment.
If pipe strain exists, then correct the piping.
4.6 Piping checklists
Model IC, ICI, ICH, ICIH Installation, Operation, and Maintenance Manual