1
2
3
4
Item Description
1.
Annular groove
2.
Pump-side end plate
3.
Driver
4.
Pump half of the coupling guard
Figure 21: Guard half installation
The annular groove in the coupling guard half must fit around the end plate.
1
2
3
Item Description
1.
Annular groove
2.
End plate (pump end)
2.
Guard half
Figure 22: Annular groove in coupling guard
3.
Use a bolt, a nut, and two washers to secure the coupling guard half to the end plate. Tighten
securely.
5.5 Install the coupling guard
50