Oil analysis should be part of a preventive maintenance program that determines the cause of a
failure. Save the oil in a clean container for inspection.
2.
The back pull out assembly consists of all parts except the casing (100). The casing (100) can
remain on the foundation and in the piping, if it is not the casing itself, which must be repaired.
Drain the casing, by removing the casing drain plug (if equipped).
3.
Does your pump use a C-face adapter?
•
If Yes: Place one sling from the hoist through the frame adapter (108) or frame (228A)
for the and a second sling from the hoist through the C-face adapter.
•
If No: Place a sling from the hoist through the frame adapter (108) or the frame (228A)
for the .
4.
Place one sling from the hoist through the frame adapter (344) and a second sling from the
hoist to the bearing frame (330)(228).
370F
330
901.11
901.42
344
120V
Figure 32: Sling placement
5.
Remove the hold-down bolts of the bearing frame foot.
6.
Remove the casing bolts.
WARNING:
•
Risk of severe physical injury or death from explosion of trapped liquid. Never use
heat to remove parts unless explicitly stated in this manual.
7.
Tighten the jackscrews evenly, using an alternating pattern, in order to remove the back pull-out
assembly.
You can use penetrating oil if the adapter to the casing joint is corroded.
8.
Remove the back pull-out assembly from the casing (102V).
Figure 33: Back pullout
6.4 Disassembly
Model IC, ICI, ICH, ICIH Installation, Operation, and Maintenance Manual