5.6.2.1 Fill the bearing frame with oil
NOTICE:
Maintain an exact oil level. If the oil level is too high, the bearing temperature can increase.
If the oil level is too low, the bearing will not be properly lubricated and could cause opera-
tional problems.
1.
Remove the oil filling plug.
2.
Pour oil into the opening.
3.
Fill until the oil level rises to the center of the oil level sight glass.
Figure 27: Oil level sight glass
5.6.2.2 Fill the bearing frame with an optional oiler
NOTICE:
Maintain an exact oil level. If the oil level is too high, the bearing temperature can increase.
If the oil level is too low, the bearing will not be properly lubricated and could cause opera-
tional problems.
The constant level oiler is supplied loose.
1.
Unscrew the reservoir from the main body (right-threaded) and set aside.
2.
Seal the main body to the bearing frame at the connection for the constant level oiler, using
PTFE sealing tape.
3.
Tighten until the threaded boss is in a vertical position.
4.
Remove the oil filling plug near the upper side of the bearing frame.
5.
Fill with oil by pouring into the connection opening until the oil level almost reaches the middle
of the oil level sight glass in the main body.
6.
Fill the reservoir using a funnel.
1
2
3
1.
Bearing frame
2.
Oil level sight glass
3.
Main body
Figure 28: Filling bearing frame oiler
7.
Place the O-ring on the reservoir spout.
8.
Place your thumb over the reservoir spout.
9.
Invert the spout and insert it into the internal threaded boss on the main body.
10. Tighten the reservoir.
The oil then flows from the reservoir into the bearing chamber.
11. Repeat steps 6 through 10 until the reservoir remains two-thirds full.
Refill with oil whenever the oil level in the reservoir drops below one-third full.