To
lubricate the X-axis,
slide the carriage to
the left*, remove the plastic plug on the left
side of the machine and lubricate through the
greasing nipple, which is now visible. The
guide rails can be accessed through the
sealing lips.
At the
Z-axis,
you must first remove the
machine tool from its holder, remove the three
plugs and push the slide all the way down. *
Through the two side holes you can put some oil
on the guide rails. The grease nipple for the
drive is now located behind the front opening.
*
If the machine is switched off, you can move the slides
by hand.