ICP 4030 iMC-P
31
/71
January
2018
Opening the housing
Remove the rear panel of the machine and the housing cover of the control unit (see
Chapter 5.4.2). The stepper motor output stages are arranged next to each other.
Configure the individual stepper motor output stages according to the following
tables:
DIP Switch - MD24 in ICP 4030
1:
Current setting 1
2:
Current setting 2
3:
Current setting 3
4:
Current reduction
5:
Step resolution 1
6:
Step resolution 2
7:
Step resolution 3
8:
Step resolution 4
Current setting (DIP-Switch 1, 2, 3,)
DIP switches 1,2,3 are used to set the motor current. Herewith the motor current can
be adapted to the used motor. The following table shows the motor currents with
corresponding switch positions.
Peak current[A]
Nominal
current[A]
SW1
SW2
SW3
1.00
0.71
ON
ON
ON
1.46
1.04
OFF
ON
ON
1.91
1.36
ON
OFF
ON
2.37
1.69
OFF: OFF: ON
2.84
2.03
ON
ON
OFF:
3.31
2.36
OFF: ON
OFF:
3.76
2.69
ON
OFF
OFF
4.20
3.00
OFF
OFF
OFF
The output stages for the X, Y and Z axes are set to a nominal
current of 3.00 A at delivery.
The output stage for the 4th axis (A-axis) is set to a rated current
of 2.03A.
Содержание ICP 4030 iMC-P
Страница 39: ...ICP 4030 iMC P 38 71 January 2018 7 Open processing programme here the NCP file Isel ncp ...
Страница 40: ...ICP 4030 iMC P 39 71 January 2018 Result text view ...
Страница 41: ...ICP 4030 iMC P Result graphic view 40 71 January 2018 8 for safety sake reference Z axis ...
Страница 59: ...ICP 4030 iMC P 14 Exploded views spare parts lists Fig 4 Exploded view ICP 4030 DU8000 58 71 January 2018 ...
Страница 61: ...ICP 4030 iMC P 69 71 January 2018 14 1 Structure axis systems X Axis ...
Страница 63: ...62 71 January 2018 ICP 4030 iMC P Y axis ...