ICP 4030 iMC-P
55
/71
January
2018
13
Declaration of conformity or declaration of incorporation
In the Machinery Directive 2006/42/EG legally binding since 29.12.2009, the term
“
Machine
“ is defined as follows (quote from MD, 2006/42/EC Article 2, Letter a):
"Machine"
•
an assembly, fitted with or intended to be fitted with a drive system other than
directly applied human or animal effort, consisting of linked parts or
components, at least one of which moves, and which are joined together
for
a specific application;
All isel CNC basic machines, supplied with a tool (e.g. processing or engraving
spindle, dosing unit, sensor like CCD camera or triangulation laser, water jet
nozzle, plasma burner or equiv.),are covered by the declaration of conformity
contained in these operating instructions.
These CNC machines are (task-related) are to be used
for a specific application
,
which results from the type of the tool (fitted on a moving axis):
Tool = Machining spindle -> Application for milling, drilling
Tool = Engraving spindle -> Application for engraving
Tool = Dosing device -> Application for gluing, dosing etc.
In the Machinery Directive 98/37/EC, which is valid until 28 December 2009, the
term "partly completed machine / incomplete machine" or in the new Machinery
Directive 2006/42/EC, which is legally binding as of 29 December 2009, the term
"incomplete machine" is defined as follows (citation MRL 2006/42/EC, Article 2, letter
g):
“
partly completed ma
chine“
“
•
An assembly that is almost machinery ,
but which in itself cannot perform a
specific application
. A drive system represents a partly completed machine.
Partly completed machinery is only intended incorporated into or assembled
with other machinery or other partly completed machinery or equipment,
thereby forming machinery to which this Directive applies;
All isel
CNC basic machines
, supplied
without a tool
(e.g. processing or engraving
spindle, dosing unit, sensor like CCD camera or triangulation laser, water jet nozzle,
plasma burner or equiv.), and therefore not to be used
for a specific application
are
covered by the declaration of incorporation contained in these operating instructions.
Содержание ICP 4030 iMC-P
Страница 39: ...ICP 4030 iMC P 38 71 January 2018 7 Open processing programme here the NCP file Isel ncp ...
Страница 40: ...ICP 4030 iMC P 39 71 January 2018 Result text view ...
Страница 41: ...ICP 4030 iMC P Result graphic view 40 71 January 2018 8 for safety sake reference Z axis ...
Страница 59: ...ICP 4030 iMC P 14 Exploded views spare parts lists Fig 4 Exploded view ICP 4030 DU8000 58 71 January 2018 ...
Страница 61: ...ICP 4030 iMC P 69 71 January 2018 14 1 Structure axis systems X Axis ...
Страница 63: ...62 71 January 2018 ICP 4030 iMC P Y axis ...