ICP 4030 iMC-P
13
/71
January
2018
•
For emergencies, you will find an emergency stop switch at the front. This interrupts
the power supply to the power electrics (motor output stages) and the frequency
converter for the main spindle drive. The shut-down takes place according to stop
category 1 (controlled stop and subsequent interruption of the power supply to the
drives).
•
Only skilled and trained persons should handle the key switch on the control
elements because in test mode there is an increased risk of injury. Keep the
spare key locked away.
•
Provide adequate ventilation for dust or gas, caused by the processing of the
materials.
•
If the sound pressure level on the machine exceeds the value of 70dB(A),
appropriate ear protection must be worn by the operators.
•
Work on and with the machine must be carried out by authorised, trained and
instructed staff. These staff must have received special training on possible risks
(in particular residual risk).
•
Before changing the tool, the machine must be switched off by operating the
emergency stop switch.
•
For cooling. no running water may be used, but only a cooling device (see
accessories), in which a water mist or air causes the cooling effect. No drops
must be allowed to form and flow under the clamping plate.
•
ATTENTION! High leakage current (earth leakage current, protective
conductor current)!
Before connecting to the AC supply network, it is essential to connect an
additional protective conductor (cross-section, installation and terminal point in
the control cabinet are described in section 5.5 Connection to the AC supply
network).
Содержание ICP 4030 iMC-P
Страница 39: ...ICP 4030 iMC P 38 71 January 2018 7 Open processing programme here the NCP file Isel ncp ...
Страница 40: ...ICP 4030 iMC P 39 71 January 2018 Result text view ...
Страница 41: ...ICP 4030 iMC P Result graphic view 40 71 January 2018 8 for safety sake reference Z axis ...
Страница 59: ...ICP 4030 iMC P 14 Exploded views spare parts lists Fig 4 Exploded view ICP 4030 DU8000 58 71 January 2018 ...
Страница 61: ...ICP 4030 iMC P 69 71 January 2018 14 1 Structure axis systems X Axis ...
Страница 63: ...62 71 January 2018 ICP 4030 iMC P Y axis ...