ICP 4030 iMC-P
26
/71
January
2018
External emergency stop not used
:
Pin 5 and 6 bridged
Pin 7 and 8 bridged
If an external emergency stop switch is used, the length of the
connection cable is max. 5m.
Using
an external
power button:
Pin 1 and 2 bridged
Connecting the external power button (closer) to pin 3 and 4
Impulses -
interface impulse controller, 8-pole socket
This interface makes it possible to trigger the functions of the front control buttons
(start, stop) as a remote function from an external control panel or another device via
I/O functions.
Pin
Description
1 Input external start button
2 +24VDC
3 Input external stop button
4 Input lamp start button
5 -24VDC
6 Input lamp stop button
7 Input length measuring probe
8 Input length measuring probe
If no external stop button is used, pins 2 and 3 must be bridged.