Goodrive3000 series medium voltage VFD Goodrive3000 PWM rectifier
-61-
Function
code
Name
Description
Setting
range
Default Modify
PI parameters
P03.16
Bus voltage filter
coefficient
0
–1.000s
0
–1.000s
0.000s
○
P03.17
Current loop
proportional
coefficient P
0.001
–30.000
0.001
–30.000
1.000
○
P03.18
Current loop
integral coefficient I
0.01
–300.00
0.01
–300.00
1.00
○
P03.19
Power factor setting
0: Angle setting
1: Reserved
0
–1
0
◎
P03.20
Rectification power
factor angle
-90.0°
–90.0°
The positive means inductive
and the negative means
capacitive.
-90.0
–90.0°
0.0°
○
P03.21
Feedback power
factor angle
-90.0°
–90.0°
The positive means inductive
and the negative means
capacitive.
-90.0
–90.0°
0.0°
○
P03.22
Reserved
●
P03.23
Reserved
●
P05 group
––Input terminals
P05.00
Reserved
●
P05.01
Polarity selection of
digital input
terminals
0x0
–0xF
0 stands for positive polarity
BIT0: S1
BIT1: S2
BIT2: S3
BIT3: S4
0x0
–0xF
0x0
◎
P05.02
Reserved
●
P05.03
Digital input filtering
time
0.000
–1.000s
0.000
–1.000
0.000s
○
P05.04
S1 terminal function
selection
0: No function
0
–15
1
◎
Содержание GD3000-01-055G-12