Goodrive3000 series medium voltage VFD Goodrive3000 inverter
-107-
Function
code
Name
Description
Setting range
Default
23: Simple PLC stop reset
24: Simple PLC pause
25: PID control pause
26: Reserved
27: Reserved
28: Reserved
29: Torque control prohibition
30: ACC/DEC prohibition
31: Reserved
32: Reserved
33: Cancel the frequency change
setting temporarily
34: DC brake
35: Shift motor 1 to motor 2
36: Shift the command to the keypad
37: Shift the command to the
terminals
38: Shift the command to the
communication
39: Pre-exciting command
40: Consumption power clear
41: Consumption power holding
42: External fault input 2
43
–63: Reserved
The parameters are used to set the corresponding functions of digital multi-functional input terminals.
Note:
Two different multi-functional input terminals cannot be set to the same function.
Set value
Function
Instruction
0
No function
The VFD will not work even when there are signals to input. The
terminals out of use may be set with no function in case of
malfunction.
1
Forward rotation
operation (FWD)
Both the forward rotation and reverse rotation of the VFD are
controlled by external terminals.
2
Reverse rotation
operation (REV)
3
3-wire control
The terminal is used to ensure the running mode of the VFD is