![INVT GD3000-01-055G-12 Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/invt/gd3000-01-055g-12/gd3000-01-055g-12_operation-manual_2085697059.webp)
Goodrive3000 series medium voltage VFD Goodrive3000 PWM rectifier
-54-
5.3 Fault information and solution
Fault
code
Type of fault
Possible causes
Countermeasures
OC
Input overcurrent
Wrong setting of current loop or
parameters
Hardware circuit abnormal
Rectifiers overload
Adjust the current loop and
parameters
Ask for service
Adjust the load or rectifier
LvI
Input undervoltage
Input power is abnormal
power-down
Input voltage detection circuit
abnormal
Check the input power
Ask for service
OvI
Input overvoltage
Input power abnormal
Interference
Input voltage detection circuit
abnormal
Check the input power
Check the external interference
Ask for service
SPI
Input phase loss
Input power abnormal
Interference
Input voltage detection circuit
abnormal
Check the input power
Ask for service
Check the external interference
PLLF
Phase-locked failed
The grid environment is abnormal
The circuit of the sample board is
abnormal
Check and find out the
interference
Ask for service
Lv
DC bus
undervoltage
Input power abnormal
Interference
Input voltage detection circuit
abnormal
Check the input power
Ask for service
Check the external interference
ov
DC bus
overvoltage
Input power abnormal
Interference
Bus voltage detection circuit
abnormal
Check the input power
Ask for service
Check the external interference
ItE
Current detection
fault
The circuit is abnormal or
interfered
Hoare components is broken
Check and settle the faults
E-DP
PROFIBUS
communication fault
PROFIBUS communication offline
Wrong PROFIBUS parameters
setting
Check communication
Re-set the relevant parameters