![INVT GD3000-01-055G-12 Скачать руководство пользователя страница 150](http://html1.mh-extra.com/html/invt/gd3000-01-055g-12/gd3000-01-055g-12_operation-manual_2085697150.webp)
Goodrive3000 series medium voltage VFD Goodrive3000 inverter
-145-
P09 group
––PID control
Function
code
Name
Description
Setting range
Default
P09.00
PID reference
source
0: Keypad digital setting (P09.01)
1: AI1 setting
2: AI2 setting
3: AI3 setting
4: HDI pulse setting
5: Multi-step speed setting
6: MODBUS communication setting
7: PROFIBUS/CANopen
communication setting
8: Ethernet communication setting
9: Reserved
0
–9
0
The parameter decides the setting target channel of procedure PID. When the frequency command
selection (P00.06, P00. 07) is 7 or the voltage setting channel (P04.27) is 6, the running mode of the VFD
is procedure PID control.
The setting target of procedure PID is a relative one, 100% of the setting corresponds to 100% of the
feedback signal of the controlled system.
The system is calculated according to the relative value (0
–100.0%) all along.
Note:
Multi-step speed reference can be realized by setting parameters of P10 group.
3, 4, 7 and 8 can be used only after inserting corresponding extension cards.
Function
code
Name
Description
Setting range
Default
P09.01
Keypad PID preset -100.0%
–100.0%
-100.0
–100.0
0.0%
When P09.00=0, the keypad sets the parameter.
Function
code
Name
Description
Setting range
Default
P09.02
PID feedback
source
0: AI1 feedback
1: AI2 feedback
2: AI3 feedback
3: HDI pulse feedback
4: MODBUS communication
feedback
5: PROFIBUS/CANopen
0
–7
0