If the differential temperature between the coolant
injection and the Air End discharge greater than
40°F (4.44°C) check for clogged oil filter/clogged
piping (Air End needs more oil in the rotors to cool
down compression).
For units with a blower drive ensure the blower is
running at 100% (50 HZ or 60 HZ depending on the
drive parameter/motor data plate).
Is the coolant at least ½ way full in the sump sight
glass when the machine is running loaded?
Inspect free movement of the check valve at the
cooler return. Tech Note 9930.
Test 4ATT thermistor for accuracy.
Clean Cooler
Xe Software Logic for RS machines:
Will occur if Enable Ambient Monitoring set point is ON,
the main motor is running and the CTD is greater than
40°F (4.4°C) for a period of 30 minutes.
Recommended Checks