17
1SV Load Solenoid Valve (N.C)
Connected to P1, the controller provides power to the
1SV load solenoid valve. When energized, 1SV opens
and applies pressure to the load cylinder, allowing the
inlet valve to open and the compressor to load. 1SV
remains closed/de-energize when the machine is
unloaded, auto restart, or OFF.
5SV Modulation Solenoid Valve
Connected to P1, the
controller provides power to
the 5SV modulation
solenoid valve when the
controller is set to Mod ACS
(machine cycles 3 times
and then activates
modulation) or Modulation
mode only. When
energized, 5SV opens
allowing the modulation
valve to adjust the inlet valve position to meet
customer’s air demand. Adjustment procedure FSB
5868.