Recommended Checks
Change HE filter
Verify wiring and instrumentation
Low Sump Pressure
Xe Software Logic for R & RS machines:
Will occur if the compressor is running unloaded or
loaded and 3APT is less than 13 psi (.9 Bar) for 15
seconds.
Recommended Checks
Is the unloaded sump pressure 18-24 psi (1.24-
1.65 Bar)? If not, adjust inlet valve per Tech Note
1497
If the main motor has rotation, check 3APT sensor
for proper reading.
Calibrate 3APT sensor. Compare reading to a
manual gauge.
Ensure 115 VAC supply to P1-1 terminal is
connected properly