94
If 2APT is reading more than 75 psi (5.17 Bar) and
the sump pressure is very low, check for blockage.
The 2nd stage gear is loose spinning on the 2
nd
stage male rotor shaft. Split motor/ Air End.
Invalid Calibration
Xe Software Logic for R & RS machines:
Will occur if the sensor zero value is +/- 10% of its
scale. This will only occur when a sensor is calibrated.
Recommended Checks
Ensure sensor part number matches with the
machine. Look in Passport or call Parts ID.
For pressure sensors ensure the pressure sensor
line reads 0 psi (0 Bar).
Load Cycles High
Xe Software Logic for RS machines:
Will occur if the average load cycles calculated over
the last 30 days is a value greater than 15. Also occurs