67
A sensor failure 4APT will be issued if the sump
pressure is over 100 psi (6.89 Bar) and the
Package Discharge Pressure (4APT) is 50 psi (3.44
Bar) less than the sump pressure. Check for
clogged separator, or broken sensor.
If the reading of the pressure sensor fluctuates, it is
faulty, the wire connection is incorrect, or the
sensor wire is close to an A/C cable creating
electrical noise.
Notes for Sensor Failure
RS-Series: 1AVPT Inlet Vacuum: This sensor failure is
only checked if the compressor is running and loaded.
Otherwise, the sensor failure for inlet vacuum is
ignored. This is due to the design of the inlet valve on
the ARES air compressors.
*See FSB 1950 in Tech Direct for R-Series Pressure
Transducer Failure Testing and Remote Mounting.