19
CDE1 Condensate No Loss Drain
Connected to P1 Triac 115 VAC to
release the condensate water from
the moisture separator.
The No-Loss Drain valve is also
capable to send a warning status
to the controller P3 terminal under
abnormal conditions.
Note: CDE2 & CDE3 No loss condensate drains are
also connected in the Triac and P3 digital inputs for
Dryer option only.
Condensate Drain Valves (9SV, 10SV,
11SV)
Connected to P1, the controller
provides power to 9SV
(Moisture Separator), 10SV (Dryer Filter Drain) and
11SV (Dryer Drain) valves. When energized, one or
more of these drain valves open to allow condensate to
release.
Note: 10SV and 11SV are used on units with integrated
dryers.