Check the hours on the separator. Replace if
exceeds PM schedule time.
Is the sump pressure 3APT and package discharge
pressure 4APT reading zero psi (0 Bar) when the
machine is not running? Calibrate. Replace faulty
sensor. Check wiring. Test quick connector.
For machines under 34°F (1.1°C), install a Low
Ambient kit to prevent excessive coolant thickness
at start-up. Some cases the separator element will
implode due to excessive thickness of the coolant
when machine starts cold.
Check for use of OEM Ingersoll Rand Parts.
High Air End Discharge Temp
Xe Software Logic for R & RS machines:
W:
Will occur if the compressor is running and 2ATT is
greater than 221°F (105°C) (97% of 228°F (108.9°C))
and the compressor is running. This condition must
exist for 3 seconds before the warning is issued.
A:
This will occur if 2ATT is greater than 228°F
(108.9°C) and the compressor is running.