Recommended Checks
Ensure the inlet valve opens when the machine is
loaded. Check control air signal to cylinder. Perform
PM in the inlet valve/blowdown block.
Ensure software revision is greater than 3.1.0.4 for
machine changing from On/Offline to Modulation.
Is the air filter clogged? Check inlet filter condition.
Is the High Dust filter option selected in Factory
settings?
Unit Too Cold To Start
Xe Software Logic for R & RS machines:
This will occur if the compressor does not have the low
ambient option, the Air End discharge temperature
(2ATT) is less than 35°F (1.7°C), and the operator
attempts to start the compressor. This fault can only
occur once a day. Once this fault occurs, the operator
can reset it and start the compressor. This fault will be
logged in the trip history to indicate that the
compressor is being started in low ambient conditions.