7SV Isolation Solenoid Valve for RS-series
7SV assists the load solenoid 1SV to overcome the
modulation pressure regulator output and allow the
inlet valve load cylinder to actuate.
TR Timing Relay for RS-Series
TR creates a 2-second delay when powering the 5SV
modulation solenoid. This allows the inlet valve load
cylinder to begin opening the butterfly valve of the inlet
valve assembly.
4SV Water Shut Off Solenoid (W/C only)
4SV is connected to the main contactor KM1 (aux
contact KM1-2) in the P1 terminal 115 VAC providing
water from customer’s water supply (open or close
loop) to cool down the machine coolant cooler and
aftercooler. The solenoid is connected to the discharge
side of the coolers to ensure water remains in the
piping when the machine is off.