Recommended Checks
Is the cooler clean front and back?
Ensure blower drives are running at max speed.
If the injected coolant temperature is above 180°F
ensure thermal control valve is operating.
When the machine is up to temperature, the airend
discharge temperature should be only a few
degrees higher than the cooler in temperature.
Ensure the cooler temperature out is at least 30°F
(-1.11°C)
LESS
than the cooler in when the
machine is up to temperature. Check TCV.
Check for piping obstruction.
Ensure check valve is working Tech Note ID 9930.
Is the sump sight glass at least ½ full when the
machine is running loaded?
Auxiliary 1 (R, RS)
Xe Software Logic
W:
This will occur if auxiliary input 1 closes. The
contact must be closed for at least 3 seconds before
the warning will occur.