87
Check Tech Flash ID 11103 to help you
troubleshoot incoming power problems.
The overload opens/breaks the circuit to P3
terminal. Ensure wires are connected.
Is the motor pulling more current than the motor
data tag calculation? Measure with an amp meter
for accuracy. If amps are close to the overload
setting, increase overload 5 amps and re-test.
The Air End is the load: Are SPM readings high or
oil samples flagged? A damaged bearing in the Air
End can increase the amps in the induction motor
opening the motor overload.
The motor overload is normally closed. If the
overload cannot be reset it is defective.
Fan Motor Overload
Xe Software Logic for R & RS machines:
Will occur if a fan motor overload relay contact opens.
The contact must be open for at least 3 seconds before
the trip will occur.
Recommended Checks