247
Appendix A: Event code tables
CTP card events (400 through 499)
Event code: 400
Message:
Power-up diagnostics failure.
Severity:
Major.
Explanation:
Power-on self tests (POSTs) detected a failed CRU as indicated by the event data.
Action:
If a CTP card failure is indicated, replace the switch. If a fan or power supply failure is indicated, contact IBM to
replace the power supply. Perform a data collection and return the CD and faulty FRU to support personnel.
Event data:
Byte
0
= CRU code as follows:
02
= CTP card,
05
= cooling fan,
06
= power supply assembly.
Byte
1
= CRU slot number.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
Event code: 410
Message:
Switch reset.
Severity:
Informational.
Explanation:
The switch reset due to system power-up, IML, or manual reset. A software reset can occur automatically after a
firmware fault (event code
411
), or be user-initiated. Event data indicates the type of reset.
Action:
No action required.
Event data:
Byte
0
= reset type as follows:
00
= power-on,
02
= IML,
04
= reset.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
Содержание SAN32M-2
Страница 2: ......
Страница 10: ...SAN32M 2 Installation and Service Manual xii...
Страница 14: ...SAN32M 2 Installation and Service Manual xvi...
Страница 42: ...SAN32M 2 Installation and Service Manual 16...
Страница 120: ...SAN32M 2 Installation and Service Manual 94...
Страница 174: ...SAN32M 2 Installation and Service Manual 148...
Страница 236: ...SAN32M 2 Installation and Service Manual 210...
Страница 240: ...SAN32M 2 Installation and Service Manual 214...
Страница 244: ...SAN32M 2 Installation and Service Manual 218...
Страница 290: ...SAN32M 2 Installation and Service Manual 264...
Страница 308: ...SAN32M 2 Installation and Service Manual 282...
Страница 311: ......
Страница 312: ...Printed in USA GC26 7763 01...