Chapter 5: Removal and replacement procedures
2. Identify the defective power supply from:
— Observing that the green LED on the FRU is off.
— At a web browser communicating with the EFCM Basic
Edition interface or at the management server (Element
Manager application), FRU failure information displayed at
the
Hardware View
,
FRU List View
, or
Event Log
.
3. Disconnect the AC power cord from facility power.
DANGER
Multiple power cords
(L003)
4. Disengage and remove the power supply:
a. Disengage the locking mechanism by rotating both finger
handles outward 90 degrees as shown in part (1) of
Figure 70
.
b. Use the finger handles to pull the power supply out of the
switch chassis as shown in part (2) of
Figure 70
. Support the
power supply as it is pulled from the chassis.
Figure 70
Redundant power supply removal and replacement
5. Inspect the
Event Log
:
— At a web browser communicating with the EFCM Basic
Edition interface, select
Event
from the
Logs
menu.
i24M1111
Содержание SAN32M-2
Страница 2: ......
Страница 10: ...SAN32M 2 Installation and Service Manual xii...
Страница 14: ...SAN32M 2 Installation and Service Manual xvi...
Страница 42: ...SAN32M 2 Installation and Service Manual 16...
Страница 120: ...SAN32M 2 Installation and Service Manual 94...
Страница 174: ...SAN32M 2 Installation and Service Manual 148...
Страница 236: ...SAN32M 2 Installation and Service Manual 210...
Страница 240: ...SAN32M 2 Installation and Service Manual 214...
Страница 244: ...SAN32M 2 Installation and Service Manual 218...
Страница 290: ...SAN32M 2 Installation and Service Manual 264...
Страница 308: ...SAN32M 2 Installation and Service Manual 282...
Страница 311: ......
Страница 312: ...Printed in USA GC26 7763 01...