237
Appendix A: Event code tables
Power supply events (200 through 299)
Event code: 200
Message:
Power supply AC voltage failure.
Severity:
Major.
Explanation:
AC input to the power supply is disconnected or AC circuitry in the power supply failed. The event only occurs
when two power supplies are installed. The second power supply assumes the full operating load.
Action:
Ensure the power supply is connected to facility AC power and verify operation of the facility power source. If the
AC voltage does not recover (indicated by event code
203
), contact IBM to replace the failed power supply.
Perform a data collection and return the CD and failed power supply to support personnel.
Event data:
No supplementary data included.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
Event code: 201
Message:
Power supply DC voltage failure.
Severity:
Major.
Explanation:
DC circuitry in the power supply failed. The event only occurs when two power supplies are installed. The second
power supply assumes the full operating load.
Action:
Contact IBM to replace the failed power supply. Perform a data collection and return the CD and failed power
supply to support personnel.
Event data:
No supplementary data included.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
Содержание SAN32M-2
Страница 2: ......
Страница 10: ...SAN32M 2 Installation and Service Manual xii...
Страница 14: ...SAN32M 2 Installation and Service Manual xvi...
Страница 42: ...SAN32M 2 Installation and Service Manual 16...
Страница 120: ...SAN32M 2 Installation and Service Manual 94...
Страница 174: ...SAN32M 2 Installation and Service Manual 148...
Страница 236: ...SAN32M 2 Installation and Service Manual 210...
Страница 240: ...SAN32M 2 Installation and Service Manual 214...
Страница 244: ...SAN32M 2 Installation and Service Manual 218...
Страница 290: ...SAN32M 2 Installation and Service Manual 264...
Страница 308: ...SAN32M 2 Installation and Service Manual 282...
Страница 311: ......
Страница 312: ...Printed in USA GC26 7763 01...